AKG PERCEPTION 420 User Instructions
Text of AKG PERCEPTION 420 User Instructions
User Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 2
Please read the manual before using the equipment!
Mode d’emploi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 14
Veuillez lire cette notice avant d’utiliser le système!
1 Precaution/Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1
Precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1
Introduction . . . . . . . . . . . . . . . . .
AKG PERCEPTION 420
1 Precaution/Unpacking
1.1 Precaution
Please make sure that the piece of equipment
your microphone will be connected to fulfills
the safety regulations in force in your country
and is fitted with a ground lead.
1.2 Unpacking
Check that the packaging contains all of the items
listed below:
• Microphone
• Spider suspension
• Carrying case
• Mini poster
Should any item be missing, please contact your
AKG dealer.
2 Description
2.1
tortion and built to resist high temperatures and
humidity, the microphone will give excellent re-
sults in a wide range of applications.
•
Polar pattern selector: Selector 1 on the
microphone front (refer to fig. 1) sets the micro-
phone polar pattern to cardioid, omnidirection-
al, or figure eight.
•
Switchable preattenuation pad: Selector 2
on the microphone rear (refer to fig. 2) lets you
increase the headroom by 20 dB for distortion-
free close-
AKG PERCEPTION 420 causes in any unidirectional microphone. The
filter rolls off at 12 dB/octave from 300 Hz
downward.
2.3 Optional Accessories
•
PF 80 studio pop screen
•
ST 305 floor stand
•
W 4000 external windcscreen
The microphone uses a true condenser trans-
ducer designed for 48-volt phantom powering to
DIN 45 596/IEC 268-15. Neither the diaphragm nor
the backplate are permanently polarized, so the
microphone needs an external power supply.
3.2 Pinout
The microphone provides a balanced output on a 3-
pin male XLR connector:
Pin 1: ground
Pin 2: hot
Pin 3: cold
3.3 Connecting the Microphone
Refer to fig. 3 below.
1. Use an XLR cable to con
AKG PERCEPTION 420 4 Using Your Microphone
4.1 General Hints
The PERCEPTION 420 is a general-purpose multi-
pattern microphone for recording, broadcast, and
onstage use.
Every instrument radiates its sound in a specific
way. Therefore, to get the best sound it is crucial to
experiment with microphone placement.
•
Refer to fig. 4. Whichever polar pattern you se-
lected, it may be good to know which way the
transducer axis is facing: the front of the
mic
4.2 Selecting Polar Patterns
Each of the PERCEPTION 420’s selectable polar
patterns is virtually frequency independent so that
reflected sound, too will be reproduced accurately
and uncolored.
•
Cardioid (center setting): This is a standard
setting for recording and gives excellent results
on all kinds of voices and a wide range of
instruments. Remember to aim the microphone
front (see fig. 4 on page 7) at the sound source.
•
Figure eight (left-han
AKG PERCEPTION 420 No sound.
Distortion.
1. Power to mixer and/or amplifier is off.
2. Channel or master fader on mixer, or volume
control on amplifier is at zero.
3. Microphone is not connected to mixer or ampli-
fier.
4. Cable connectors are seated loosely.
5. Cable is defective.
6. No supply voltage.
1. Channel gain control on mixer set too high.
2. Microphone too close to sound source.
3. Microphone sensitivity set too high.
1. Switch power to mixer
AKG PERCEPTION 420 Crackling noises or low output.
•
Partial short circuits due to excessive humidity.
•
Place microphone in warm, dry room and allow to
dry.
Problem
Possible Cause
Remedy
AKG PERCEPTION 420
6 Troubleshooting
AKG PERCEPTION 420 Type:
1-inch dual-diaphragm, true condenser
pressure-gradient microphone
Polar patterns:
cardioid, omnidirectional, figure eight
Open-circuit sensitivity
at 1kHz (cardioid):
28 mV/Pa (-31 dBV ±2 dB)
Frequency range:
20 Hz to 20 kHz
(see frequency response graphs)
Impedance:
≤200 ohms
Recommended load impedance:
≥1000 ohms
Equivalent noise level
to CCIR 468-2:
26 dB
Equivalent noise level
to IEC 60268-4 (A-weighted):
16 dB-A
Signa
AKG PERCEPTION 420 Frequency Response (cardioid)
Cardioid Polar Diagram
Frequency Response (omnidirectional)
Omnidirectional Polar Diagram
AKG PERCEPTION 420
7 Specifications
AKG PERCEPTION 420 Frequency Response (figure eight)
Figure Eight Polar Diagram
7 Specifications
AKG PERCEPTION 420 Page
1 Précautions/Déballage........................................................................15
1.1
Précautions...............................................................................15
1.2
Déballage .................................................................................15
2 Description .........................................................................................15
2.1
Introduction..............
AKG PERCEPTION 420 1 Précautions/Déballage
1.1 Précautions
Assurez-vous que le matériel auquel vous aller
connecter votre microphone répond bien aux
règlements de sécurité en vigueur dans votre
pays et qu’il possède une mise à la terre.
1.2 Déballage
Vérifiez si l’emballage contient bien tous les articles
indiqués ci-dessous:
• Microphone
• Spider
• Mallette
• Mini-poster
S’il manque un de ces articles veuillez contacteur
votr
en même temps que des microphones ou aut-
res matériels de communication sans fil. Le
corps de micro massif et extrêmement résis-
tant ainsi que la grille avant robuste protègent
le microphone contre les manipulations bruta-
les courantes sur la scène.
•
Importante marge avant saturation, distor-
sion minimum : Capable de restituer sans dis-
torsion perceptible des niveaux de pression
sonore allant jusqu’à 155 dB et construit pour
résister aux
du microphone (voir fig. 2, page 17) permet
d’augmenter de 20 dB la marge avant satura-
tion pour un enregistrement de proximité ex-
empt de distorsions. Le pré-atténuateur de sen-
sibilité permet d’éviter que le niveau de sortie
du microphone n’occasionne, en particulier à
basses fréquences, une surcharge des trans-
formateurs miniatures fréquemment utilisés
sur les étages d’entrée des tables de mixage,
etc.
•
Filtre coupe-bas : Le s�