BMS Bulut Makina Sanayi Ve Ticaret Ltd. Şti.

İkitelli Organize Sanayi Bölgesi Dolapdere Sanayi Sitesi Ada 4 No : 7-9 Başakşehir / İSTANBUL Tel : 0 212 671 02 24 / 25 Fax : 0 212 671 02 26 web site : www.bulutmak.com e-mail : [email protected] OPERATION MANUAL KULLANMA KILAVUZU ...

History ................................................................................................................ 2

1.2. Leeb Hardness Test (definition) .......................................................................... 2 1.3. Notation of Leeb’s Hardness .............................................................................. 2 2. Features and Applications .................................................................................... 3 2.1. Introduction ........................................................................................................ 3 2.2. Specifications ................................. ...

The Leeb measuring method was first brought into measurement technology in 1978. It is defined as the quotient of an

impact body’s rebound velocity over its impact velocity, multiplied by 1000. Harder materials produce a higher rebound velocity than softer materials. For a specific group of material (e.g. steel, aluminum. etc.), Leeb hardness value represents a direct relationship to its hardness properties. For ordinary metal, conversion curves of hardness HL versus other standard static hardness (HB, HV, HRC, etc.) are available, enabling you to convert HL into other hardness values. 1.2. Leeb Hardness Test (definition) An ...

2. Features and Applications

2.1. Introduction HARTIP 2000 is an innovative portable Leeb hardness tester with our new patent technology which makes HARTIP 2000 a universal impact direction hardness tester. It is no need to set up impact direction when taking measurement by any angle. Therefore, HARTIP 2000 offers a linear accuracy comparing to the angle compensating method. HARTIP 2000 is also a cost saving hardness tester and has many other features. 2.2. Specifications Principle Leeb hardness measurement Accuracy ±0.3% @ HL=800 Repeatability ±2HL Display Digital LCD with backlight Impact direction Universal angle type Hardness scale HL/HRC/HRB/H ...

3.2. Function of Key

: Read the memory : Power On Power Off : Menu Increase the value Turn the page forth : Change parameter Decrease the value Turn the page back : Delete the current reading Delete the stored values Press for 3 seconds to activate/deactivate direction indicator : Confirm the setup View the statistics values 3.3. Special Features of Impact Devices Type Brief Description D Universal standard unit for majority of hardness testing assignments. DC Extremely short impact device, other specs identical with type D. - highly confined spaces - holes and cylinders - internal measurements on assembled machines D+15 Slim front section Applicatio ...

5. Measurement and Conversion Table

Range for measurement and conversion: IMPACT DEVICE D/DC HLD: 170-960 MATERIALS HRC HRB HB HV HS σb (N/mm2) Steel & cast steel 20.0-67.9 59.6-99.5 80-647 80-940 32.5-99.5 255-1710 Cold work tool steel 20.5-67.1 80-898 1170-2639 Stainless steel & High-temp. resistant steel 17-62.4 46.5-109 85-655 85-802 740-1725 Cast iron with lamellar graphite (GG) 21-59 24-100 93-334 90-698 Cast iron with nodular graphite (GGG) 21-60 24-100 131-387 96-724 Cast aluminum alloys 23-85 20-159 22-193 Copper-zinc alloys (Brass) 13-95.3 40-173 Copper-aluminum / Copper-tin alloys (Bronze) 14-100 60-290 Wrought copper alloys 14-100 45- ...

For coupling purposes,

The coupling surface between the sample and base plate should be flat, plane parallel and ground. A thin proper layer of coupling paste is to be applied to the contact surface of the sample. The sample should be firmly pressed against the surface of the base plate by moving it with a circular motion. The direction of impact should be perpendicular to the coupling surface. For the coupling operation, the following prerequisites must be fulfilled: The contact surface of the sample and the surface of the base plate must be flat, plane parallel and ground. The direction of the test impact must be perpendicular to the coupled surfac ...

Surface of the test sample should not be magnetic.

For test sample of curving surface with radius of curvature R less than 30mm, a small support ring should be used. Supporting the Samples during Testing Types of impact devices Classification of samples Heavy-weigt medium-weight light-weight D/DC/D+15/DL >5kg 2 - 5kg 0.05 – 2kg G >15 kg 5 - 15kg 0.5 – 5kg C >1.5kg 0.5 - 1.5kg 0.02 - 0.5kg When measuring hardness with HARTIP 2000, the following has to be noticed: Despite the low mass of the impact body and low impact energy, a relatively large impact force within short duration is generated when the impact body hits the measuring surface. Types of ...

7.2.1. Probe Setup

Press key to enter the Probe setup menu. Press key to change probe between D, DL, D15, G and C. Press key to confirm the setting or press key again to change probe. 7.2.2. Materials Selection The material selected is prior to the conversion from HL value to other scales. Press key to enter into the menu until “MATE” displays on LCD. Press key to change material from M1M2M3 ... M11 with each pressing key . Press key to confirm the setting or press key again to change other parameters. M1: Steel & Cast Steel M2: Cold Work Tool Steel M3: Stainless Steel & High-temp. Resistant Steel M4: Cast Iron with L ...

7.2.4. Mean Time

With HARTIP2000, the statistics values can be calculated automatically after setup mean time. Press key consecutively to enter into menu until “AVER” displays on LCD. Press key to select mean time from 0345 circularly by each pressing key . Press to confirm the setting or press key again to go to next item of menu. 7.2.5. Storage The HARTIP2000 has a memory capacity of 300 data. The stored values can be re-readable on LCD. Press key consecutively to enter into menu until “SAVE” displays on LCD. Press key to change the setting between “OFF” and “ON” alternatively. Press key to confirm the setting or pr ...

Take measurement at different impact direction to see if the arrow direction on LCD is compatible to your probe

angle. If you find the arrow direction on LCD is not compatible to your actual probe angle, you can calibrate the instrument to make impact direction compatible. Please refer to 7.7Calibration (Compensation). Please note: once the instrument is switched off, the function of displaying impact direction will be deactivated automatically. 7.3. Operation 7.3.1. Take measurement Switch on the tester, the instrument will go into measuring mode automatically. If the parameters are needed to change, please refer to 7.2. 7.3.2. Load spring force Ho ...

Please note:During the measurement, the impact device must be placed vertically with a little force against

the surface of workpiece. Otherwise, it may affect the accuracy. 7.4. Data storing and re-reading Set the storage function of tester to be activated. Please refer to 7.2.5. A “S” displays on LCD. At this time, all measuring values will be stored automatically into the memory. After storage is activated, press key after “MEMR” displays and then the last stored value will display. Press key or to turn the page and view measuring values. When “EOF” or “bOF” displays with turning page, it reminds you it is at the end. Clear th ...

The tester is designed to print our measuring values by two ways. One is print-out all from memory and the other

is print-out online while measuring. 7.6.1. Printing stored values Activate the storage function on the tester, there is a “S” displays on the right side of LCD. Please refer to 7.2.5 Storage. Connect the tester to the printer with cable and then power on the printer. For Bluetooth connection, the printing cable is not necessary. (The printer and cable will be ordered optionally) Press key , a “R” displays on LCD which means the tester is in the re-readable mode, at this time, the last value will display on LCD. P ...

At the mode of calibration, you are asked to take 3 measurements (impact direction: downward) on standard

test block in total. Please follow up the direction indication on LCD to take measurements. During the measurements, you can delete the unsatisfied reading by press key . After taking 3 measurements on test block, press key to display average value. At this time, the arrow disappears and an indicator “AVE” is displayed on the right bottom of LCD. If the average value differs from the standard value of test block, you can press and hold key for 3 seconds, “CALD” will flash once on the screen, and then an indicator “ADJ” will disp ...

Please note:When the calibration is only for impact direction instead of value, just make the same operation

and don not change value on LCD. After you finish the whole operation of calibration, the impact direction will be also calibrated. 7.8. Restore factory settings and check serial no. Restore factory settings 1. Press and hold button while turning on the tester, "ESC" will display on the LCD after release . 2. Press consecutively, the "ESC" and "FSET" will display on the LCD in turn. 3. Press key to restore factory settings when "FSET" displays on the LCD, and then the tester will return to the measuring mode. Check serial no. 1. Press an ...

Test Equipment PDF Instructions

UNITEST 2000 alpha
BEHA UNITEST 2000 alpha
03.09.2026 40 pages

 Bedienungsanleitung  Instruction Manual  Mode d´emploi  Manual de instrucciones 2000 α alpha 2000 β beta 2000 γ gamma UNITEST ® Professional manual for the BEHA UNITEST 2000 alpha Test Equipment. It explains configuration options and device calibration, operating guidelines, error handling.

OneTouch AT G2
Netscout OneTouch AT G2
31.05.2026 396 pages

Revised 01/2018 for Software Release v6.5.1 © 2018 NETSCOUT SYSTEMS, Inc. All Rights Reserved. All product names are trademarks of their respective companies. OneTouch ™ AT G2 and OneTouch ™ AT Network Assistant User Manual Installation reference manual for the Netscout OneTouch AT G2 Test Equipment. This reference includes installation procedures, maintenance, product specifications.

CA03
FLOW Technology CA03
04.05.2026 18 pages

8930 South Beck Avenue, Suite #107, Tempe, Arizona 85284 U.S.A. Telephone (480) 240-3400, Fax (480) 240-3401 CA03 SIGNAL CONDITIONER Installation, Operation and Maintenance Manual SERIAL NUMBER_________________________________ TM-87917 REV. H PUBLISHED B Detailed user guide for the FLOW Technology CA03 Test Equipment. This manual outlines installation steps and firmware updates, performance guidelines, network setup, installation guides.

SC1
Raven SC1
10.05.2026 88 pages

Copyright 2019 Raven SC1™/TC1™ (software version 1.5) Calibration & Operation Manual for Tractors and Sprayers 016-4010-005 Rev. E 10/2019 E33533 Reference manual for the Raven SC1 Farm Equipment. It details operating modes and adjustment procedures, setup guidelines, compatibility information, operating guidelines.