DIGITAL ELECTRONIC THERMO-

CONTROLLER WITH DEFROSTING FUNCTION OPERATING INSTRUCTIONS Vr. 02 (ENG) - 04/12 - cod.: ISTR-MW09-ENG02 ASCON TECNOLOGIC S.r.l. VIA INDIPENDENZA 56 27029 VIGEVANO (PV) ITALY TEL.: +39 0381 69871 FAX: +39 0381 698730 http:\\www.ascontecnologic.com e-mail: [email protected] FOREWORD This manual contains the information ne ...

When the keyboard is locked it can be used together with the UP

(hold pressed for 5 sec.) key to unlock the keyboard. 2 - Key DOWN : In programming mode is used for decreasing the values to be set and for selecting the parameters. 3 - Key UP/DEFROST : In normal mode can be used to start/stop manual defrosting (hold pressed for 5 sec.). In programming mode ...

parameters not protected and the par. “r.P” (through which will be

possible to have access to the “protected” parameters.) 5 sec. Hold for 2 sec. Hold for 2.5 - RESET PARAMETERS TO DEFAULT VALUE/LEVEL The instrument allows the reset of the parameters to values programmed in factory as default. To restore to the values of default the parameters set th ...

If there is no power, and then power returns, the system always

sets itself in the condition it was in before the black-out. The ON/Stand-by function can be selected using the key U if the parameter "t.UF" = 4. Pressing the key U for at least 1 sec., it is possible to switch the instrument from the ON status to Stand-by status and vice versa. 4.2 - MEASURING ...

This allows to perform the first defrost to a different interval from

"d.di." time. If it is desired that to every instrument power on a defrost cycle is realized program the par. "d.Sd" = oF. Instead if is desired all defrost to the same interval program "d.Sd" = "d.di." Automatic defrost function is disable when “d.di” = oF. The instrument provides to ...

5 - PROGRAMMABLE PARAMETERS TABLE

Here below is a description of all the parameters available on the instrument. Some of them may not be present because depend on the model/type of instrument. oF oF/ 0.01 ÷ 9.59 (min.sec ) ÷ Out delay between switching-on P.P3 18 oF oF/ 0.01 ÷ 9.59 (min.sec ) ÷ 99.5 (min.sec.x10) Out delay after switch off P.P2 17 oF o ...

6.2 - CLEANING

We recommend cleaning of the instrument only with a slightly wet cloth using water and not abrasive cleaners or solvents. 6.3 - GUARANTEE AND REPAIRS The instrument is under warranty against manufacturing flaws or faulty material, that are found within 12 months from delivery date. The guarantee is limited to repairs or to the replacement of ...

7.5 - INSTRUMENT ORDERING CODE

W09- a b c d e f g h ii jj a : POWER SUPPLY H = Supply 100..240 VAC b : OUT R = Out Relay SPDT 8A-AC1 c : BUZZER - = (No) B = Buzzer d, e, f, g, h : INTERNAL CODES ii, jj : SPECIAL CODES ASCON TECNOLOGIC - W09- - OPERATING INSTRUCTIONS - Vr. 02 - 04/12 - ISTR-MW09-ITA02 - PAG. 8 ...