Key Pages of Document

AC/DC True RMS

Clamp Meter Model No. 73756 © Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.craftsman.com 062006 • Safety • Operation • Maintenance • Español CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. ...

TABLE OF CONTENTS

Warranty Page 3 Safety Instructions 4 Safety Symbols 5 Control and Jacks 6 Symbols and Annunciators 6 Specifications 7 Battery Installation 9 Operating Instructions 10 AC/DC Current Measurements 10 DC Voltage Measurements 11 AC Voltage Measurements 12 Resistance Measurements 13 Capacitance Measurements 13 Fr ...

ONE YEAR FULL WARRANTY

ONE YEAR FULL WARRANTY ON CRAFTSMAN PROFESSIONAL AC/DC TRUE RMS Clamp Meter If this CRAFTSMAN Professional AC/DC True RMS Clamp Meter fails to give complete satisfaction within one year from the date of purchase, RETURN IT TO THE NEAREST SEARS STORE OR OTHER CRAFTSMAN OUTLET IN THE UNITED STATES, and Sears will replace it, free of ch ...

This meter has been designed for safe use, but must be operated

with caution. The rules listed below must be carefully followed for safe operation. 1. NEVER apply voltage or current to the meter that exceeds the specified maximum: Input Limits Function Maximum Input A DC or A AC 800A DC/AC V DC or V AC 600V DC/AC Resistance, Capacitance ...

This symbol adjacent to another symbol,

terminal or operating device indicates that the operator must refer to an explanation in the Operating Instructions to avoid personal injury or damage to the meter. This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. This CAUTI ...

CONTROLS AND JACKS

1. Current clamp 2. Clamp opening trigger 3. Control buttons: • Data Hold • Mode • Peak • Backlight • DCA Zero 4. Backlit LCD Display 5. COM negative input jack for black test lead 6. Rotary function switch 7. V•�•CAP•TEMP•HZ• positive input jack for red lead SYMBOLS AND ANNUNCIATORS HOLD Da ...

± (5% + 10d)

400.0A 0.1A ± (5% + 10d) DC Current (A DC) 800A 1A ± (2.8% + 10d) 40.00A 0.01A ± (5% + 10d) 400.0A 0.1A ± (5% + 10d) AC Current (A AC) 50/60Hz 800A 1A ± (2.8% + 10d) 400.0mV 0.1mV ± (0.8% + 10 digits) 4.000V 1mV 40.00V 10mV 400.0V 0.1V ± (1.5% + 2 digits) DC Voltage (V DC) ...

± (3% reading + 9ºF)

Temperature -20 to 760ºC 1ºC ± (3% reading + 5ºC) NOTE: Accuracy specifications consist of two elements: • (% reading) – This is the accuracy of the measurement circuit. • (+ digits) – This is the accuracy of the analog to digital converter. Clamp jaw opening 1.2” ...

Max 80% up to 87

oF (31 oC) decreasing linearly to 50% at 104 oF (40 oC) Storage Humidity <80% Operating Altitude 7000ft. (2000) meters maximum Weight 10.7 oz (303g) Size 9.0” x 3.1” x 2.0” (229 x 80 x 49mm) Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Ove ...

WARNING: Risk of electrocution. High-voltage circuits, both AC

and DC, are very dangerous and should be measured with great care. 1. ALWAYS turn the function switch to the OFF position when the meter is not in use. 2. If “OL” appears in the display during a measurement, the value exceeds the range you have selected. Change to a ...

⚠️ Download Safety

The Measuring Instruments Owner's manual (21 pages) is completely safe to download (last scan date: 16/07/2026).