- 1 -

Carbon Monoxide Alarm Owner’s Manual Owner’s Manual Owner’s Manual Owner’s Manual Sealed Lithium Battery Powered CA6000 Sealed Lithium Battery Powered CO Alarm, Single Station CA6050 Sealed Lithium Battery Powered CO Alarm with LCD Digital Display and Peak Level Memory, Single Station Manual P/N: 240-1104 Rev-03 Feb 6, 2013 ...

- 2 -

CONTENTS OF THIS MANUAL 1. IMPORTANT MESSAGE AND INSTRUCTIONS 2. WARNING MESSAGES 3. FEATURES AND SPECIFICATIONS 4. INFORMATION ABOUT CARBON MONOXIDE 5. RECOMMENDED LOCATIONS OF ALARMS 6. LOCATIONS TO AVOID 7. INSTALLATION INSTRUCTIONS 8. FUNCTIONS AND OPERATION 9. TEST AND MUTE ALARM 10. WHAT TO DO WHEN THE ALARM SOUNDS 11. LIMITATIONS OF CARBON MONOX ...

- 3 -

the other label near a source of fresh air where you plan to gather when the carbon monoxide alarm signals are activated. After installation is completed, TEST your alarm by pressing the TEST/RESET/MUTE button for at least 5 seconds. Detailed testing instructions are outlined in Section 9. DO NOT TRY TO TEST THIS ALARM IN ANY OTHER WAY: If no alarm s ...

- 4 -

3. FEATURES AND SPECIFICATIONS • Factory Sealed Lithium Batteries with Soldered Connections • Unique Battery Activation/Deactivation Switch • Accurate and Reliable Water-Based Electrochemical Sensor • Integrated Filter for Removing Nuisance Gases • Samples for Carbon Monoxide (CO) Every 10 Seconds • Optional Alpha Numeric LCD Readout with M ...

- 5 -

SPECIFICATIONS CO Response Times: 70 PPM: 60-240 minutes, 150 PPM: 10-50 minutes, 400 PPM: 4-15 minutes, Sensor Type: Electrochemical Operating Temperature: 40oF (4.4oC) to 100oF (37.8oC) Audible Signal: Buzzer Horn Sounds 85 dB at 10 feet Visual Signal: • Green LED Indicates Power On • Alarm Red LED Indicates CO Alarm • Service Red LED Indic ...

- 6 -

4. INFORMATION ABOUT CARBON MONOXIDE WHAT IS CARBON MONOXIDE? Carbon monoxide (CO) is a highly toxic, invisible, odorless, tasteless gas. HOW IS CO GENERATED IN THE HOME? Carbon monoxide is generated through incomplete combustion of fuel in various home appliances. Faulty ventilation of furnaces, water heaters, fireplaces, wood burning stoves, and spa ...

- 7 -

5. RECOMMENDED LOCATION OF ALARMS The Consumer Products Safety Commission (CPSC) recommends the use of "at least one CO alarm per household located outside each sleeping area." (See diagrams "A" and “B”). CO poisoning can happen anywhere in the home, but because most CO poisoning cases occur while people are sleeping, the best location for the CO a ...

- 8 -

6. LOCATIONS TO AVOID NEAR THE COOKING AREA: Do not install the alarm within five feet of cooking appliances. CO may be generated in the cooking process and cause nuisance alarms. Also, cooking grease can build up on the alarm and cause alarm failure. WITHIN FIVE FEET OF A FURNACE, WATER HEATER, OR SPACE HEATER: These devices often spill out small amo ...

- 9 -

Mounting hole is closed when switch is in initial position To activate CO Alarm, slide the alarm down onto mounting plate, or slide to STOP. Lift up Stop and slide to left to permanently deactivate CO Alarm when END-OF-LIFE signals are initiated CO Concentration and Response Time 400ppm : 4- 15 minutes (C) A ...

- 10 -

8. FUNCTIONS AND OPERATION OPERATION: The CO alarm is operational once the activation switch is slid to ON position. The green LED will flash once every 30 seconds. The model CA6050 LCD will also continuously display to indicate that the CO alarm’s power is active. LOW BATTERY CONDITION: When the battery voltage drops below an acceptable leve ...