Konig CMP-BARSCAN31 Manual 

Text of the manual

Table of Contents:

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 4 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 6 Charging the CMP-BARSCAN40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 7 Barcode settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 7.1 Edit setup barcode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 7.2 Macro/Special keys setup barcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 7.3 Termination string setup barcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 7.4 Symbologies on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 7.5 Symbologies set up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 7.6 Multiscan functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 7.7 ID character setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 8 ASC11 reference table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 9 Default setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 10 Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 1) Introduction: The Barcode scanner provides an accurate, easy and fast method of data entry and data storage for computerized information systems. The scanner can be connected to any computer system with a USB port. The scanner can be used in different situations, for example in a shop related area to scan the products, or in a warehouse area to scan the stock etc. When the scanner is placed in its holder, it will automatically scan all barcodes that are held under the laser. 2) Features: • With automatic trigger operation that lengthens the life of the laser head. • New electricity saving way of scanning, 650nm high speed laser scanning technique enables it to read various kinds of barcodes accurately and quick. With a scan rate up to 74 scans/sec, and a fault rate of less than one millionth. • Dustproof and waterproof design to IP65 standards, assures reliable functionality under any circumstance. • Designed with special thin diameter wire material, and with a better durability, flexibility and anti-pull intensity than most common products. • Unique pikestaff like holding handle. The ergonomic design, makes using the scanner very comfortable. • Anti-impact design, tested to withstand a fall from 1.5 m on a concrete floor.

The CMP-BARSCAN40 has a few extra features:

• The 2.4 GHz wireless frequency-skip technique enables users to use several scanners in close proximity synchronously without interfering with each other. • High capacity 2Ah Li-polymer battery, can be in standby for 500 hours and use continuously for 10 hours (idle electric current less than 50μA). 3) Specifications: Type of light source: 650nm laser Manner of using: Portable or setting in bracket Rate of wrong code: One millionth Laser safety capability: CDRH CLASS II, IEC CLASS II Type of bar codes: UPC-A, UPC-E, Industrial 2 of 5, EAN8, EAN13, Code 128, EAN 128, Code39, Code93, Codebar125, etc. Support interface: USB Manner of scan starting: Manual or automatic trigger Resolution(pcs0.9): 0.10mm(4mil) Width of reading: 60mm at 30mm away from the object; 98mm at 100 mm away from the object Depth of field: 10-420mm (pcs0.9, density 0.25) Speed of code reading: 74times/second Precision of code reading: 0.10-0.825mm Distance of code reading: 10-510mm Compatible with: Microsoft® Windows 98se/ME/XP/Vista Drop test: 100 times/1.5m CMP-BARSCAN40 Extra features: Power supply: 5 V Battery capacity: 1200 mAH Idle electric current: less than 50μA Working electric current: 120 mA Stand by current: 30 mA Intensity of bearing light Sunlight: 3.000lux max EMI: In compliances with the EN50081. par1 specifications EMS: In compliances with the EN50082. par1 specifications

USB Cable version: (CMP-BARSCAN31)

Connect the scanner line to the computer USB port directly. Note: after you have connected the scanner, scan the barcode below to ensure the scanner works normally. 000600 USB dongle version: (CMP-BARSCAN40) Changing to dongle method: You can see if the scanner is connected to the dongle by checking the light on the dongle while scanning. When you are scanning, a little light should be flashing on the dongle. Only one scanner can be connected to each dongle. If you want to change the dongle you must disconnect first. Scan the barcode below and the connection with the dongle will be terminated. 0R Now you can power on the dongle to which you want to change. Press the button of the scanner; you can see the light of the dongle flashing. It shows that the dongle is matched with the scanner, now you can use the scanner normally. Note: The scanner chooses the closest free dongle completely random. So make sure only the dongle you want to use is connected to a computer

In order to decode normally, the laser of the scanner must cover the whole barcode.

Good. Fault.