SPL performer s800 Operation & User’s Manual
Text of SPL performer s800 Operation & User’s Manual
Mastering Grade Listening
Performer s800
Stereo Power Amplifier
PWR
PROTECT
TEMP
VOLTAiR
120V DC Audio Rail
Performer s800 – User Manual
Stereo Power Amplifier
and thank you for choosing the Performer s800.
The Performer s800 amplifier is an ultra-compact power amplifier that delivers 2 x 285 W to 4 ohms loudspeak-
ers. In bridge mode it delivers 450 W into 4 or 8 ohms.
VOLTAiR technology is what we also call the SPL 120V Rail Technology within the Professional Fidelity series. This
makes the Performer s800 an outstandig device in terms of dynamic range, signal-to-noise ratio and headroom
delivering an
SPL performer s800 Rear view (Stereo Mode)
6
Rear view (Bridge Mode)
7
VOLTAiR – 120V Rail Technology
8
Comparisons
9
Inputs
11
Slave Thru
12
Trim
12
Bridge Mode
12
Speaker outputs
13
Bridge Mode
14
Protection circuits
15
DC Protection
15
Overheating protection circuit
15
AMP CTL (Amplifier Control)
16
Specifications
17
Line Inputs & Line Outputs
17
Speaker outputs
17
Output power
17
Output voltage
18
Output impedance
18
Damping facto
Read thoroughly and follow the instructions as well as the security advices of the Quickstart
which is enclosed in the scope of delivery! You can also download the Quickstart here.
By pressing the
-Button you get to the table of contents.
By pressing the
-Button you get to the front view of the unit.
By pressing the
-Button you get to the rear view of the unit.
By pressing the
-Button you get to the previous content.
Stereo Power Amplifier
PWR
PROTECT
TEMP
VOLTAiR
120V DC Audio Rail
Power LED
1
Rear view (Stereo Mode) Voltage Selection:
Fuse:
1. Remove Fuse Holder
2. Exchange Fuses
3. Flip Over 4. Reinstall
AVIS: RISQUE DE CHOC ÉLECTRIQUE • NE PAS OUVRIR
RISK OF ELECTRIC SHOCK
D O N O T O P E N
CAUTION
XLR WIRING
Pin 1 = GND
Pin 2 = Hot (+)
Pin 3 = Cold (–)
Minimum Load: 4Ω
Minimum Load: 4Ω
Minimum Load: 8Ω
Serial
Number
Made in Germany
~ 115V AC / ~230V AC, 50 Hz / 60 Hz, P max. 855VA
Mono
3,5mm
Jack
INPUT L
INPUT L
AMP CTL
AMP CTL
Rear view (Bridge Mode)
Bridge Mode
Bridge Mode
Voltage Selection:
Fuse:
1. Remove Fuse Holder
2. Exchange Fuses
3. Flip Over 4. Reinstall
AVIS: RISQUE DE CHOC ÉLECTRIQUE • NE PAS OUVRIR
RISK OF ELECTRIC SHOCK
D O N O T O P E N
CAUTION
XLR WIRING
Pin 1 = GND
Pin 2 = Hot (+)
Pin 3 = Cold (–)
Minimum Load: 4Ω
Minimum Load: 4Ω
Minimum Load: 8Ω
Serial
Number
Made in Germany
~ 115V AC / ~230V AC, 50 Hz / 60 Hz, P max. 855VA
Mono
3,5mm
Jack
INPUT L
VOLTAiR – 120V Rail Technology
VOLTAiR is the synonym for our 120V Rail Technology within the Professional Fidelity series. The audio signals are
processed with an unequalled +/-60V DC, which corresponds to twice that of discrete operational amplifiers and
four-times that of semiconductor operational amplifiers.
VOLTAiR Technology reaches outstanding technical and sonic performances. Technically especially in terms of
dynamic range and headroom and son
These diagrams show how our VOLTAiR Technology compares to other circuits.
The direct relation between operating level and maximum level is fundamental for the classification: the higher
the operating level, the higher the maximum level a circuit can handle. And since virtually all essential acoustic
and musical parameters depend on this relation, a higher operating voltage also has a positive impact on the
dynamic range, distortion limit and
SPL performer s800 Do bear in mind that dB scales do not represent linear but rather exponential increases. A 3 dB increase corre-
sponds to doubling the acoustic power, +6 dB correspond to twice the sound pressure level, and +10 dB corre-
spond to twice the perceived loudness.
When it comes to volume, the VOLTAiR Technology exhibits a performance, in regard to maximum level and dynamic
range, that is twice that of common components and circuits given that its values a
The Performer s800 is equipped with XLR inputs (8, 12) for balanced connection to a pre-
amp. Full output power (2 x 285 W RMS into 4 ohms or 2 x 185 W RMS into 8 ohms) is per-
formed at +6 dBu at the input.
For unbalanced connection with e.g. RCA output connect Pin 3 to Ground in the external
connector.
Made in Ger
INPUT R
INPUT R
DE (–)
SPEA
–
0
-
5
.
5
-
5
-
4
.
5
-
4
-
3
.
5
-
3
-
2
.
5
-
2
-
1
.
5
-
1
-
0
.
5
T
R
I
M
T
H
R
U
I
N
P
The input is passively fed to the SLAVE THRU (9, 13) output for bi-wiring applications.
Trim
The input can be lowered with the TRIM switch (10, 14) from 0 dB to -5.5 dB in 0.5 dB
steps. This is helpful if you want to use multi speaker sets or speakers in a bi-wiring applica-
tion. It allows to level speakers with different efficiency to equal loudness.
Bridge Mode
In bridge mode only the left input is used. The right input and the trim switch
You can connect 4 or 8 ohms loudspeakers to the speaker outputs
(11, 15). You can either use the ø4 mm cable hole (screwable) or the
banana plugs of the gold-plated loudspeaker binding posts.
Make sure not to mix up the polarity of the loudspeaker outputs.
Voltage Selection:
Fuse:
1. Remove Fuse Holder
2. Exchange Fuses
3. Flip Over 4. Reinstall
Minimum Load: 4Ω
Serial
Number
Made in Germany
~ 115V A
INPUT R
INPUT R
SPEAKER OUTPUT R
SPL performer s800 The Performer s800 can be operated in bridge mode to combine both channel amps for maximum power (450 W
RMS into 4 or 8 ohms). Only use the left input then.
•
Set the BRIDGE MODE (7) switch to ON.
Warning: Power down the Performer s800 with the mains switch (5) before
you activate the BRIDGE MODE switch.
In bridge mode you only connect a single loudspeaker to the Performer s800 power amplifier. Use the positive
binding post (+) of the left
The Performer s800 has protection circuits against DC (direct current) voltage at the output and against
overheating.
DC Protection
If DC is detected at the outputs, the Performer s800 automatically switches off. DC voltage can be an indication
for a defective power stage. The PROTECT LED (2) on the front indicates that the protection circuit is activated and
the power stage has been switched off.
The Performer s800 does not automati
AMP CTL (Amplifier Control)
If you use the Performer s800 via AMP CTL with a SPL Phonitor x or SPL Director as a pre-
amp, the Performer s800 can be switched between standby and operation together with the
Phonitor x or the Director. Therefore you only have to connect the AMP CTL jacks (6) with a
3,5 mm mono mini jack cable.
Voltage Selection:
Fuse:
1. Remove Fuse Holder
2. Exchange Fuses
3. Flip Over 4. Reinstall
AVIS: RISQUE
R
D
Minimum Load: 4Ω