OTT SE 200 Operating Instructions Manual
Read Online
Read the OTT SE 200 Operating Instructions Manual online using the built-in PDF viewer.
Key Pages of Document
1 Scope of Supply 4 2 Order Numbers 4 3 Introduction 5 4 Installing the SE 200 6 4.1 Installing the SE 200 as a stand-alone device 7 4.2 Installing the SE 200 as an attachment (see Appendix A) 7 4.3 Installing the SE 200 in an observation well (see Appendix B) 7 5 Connecting the SE 200 8 5.1 Connecting the SE 200 to any datalogger using an SDI-12 interface 8 5.2 Connecting the SE 200 to any datalogger using 4 … 20 mA 8 5.3 Connecting ...
� OTT SE 200 – 1 Shaft encoder with permanently attached connecting cable (10 m, 15 m or 30 m); SDI-12 or SDI-12/4 … 20 mA interface; float pulley for float cable with 1 mm diameter or for the bead chain – 1 set of installation accessories – 1 operating instructions – 1 Factory acceptance test certificate (FAT) 2 Order numbers � OTT SE 200 Shaft encoder 63.060.001.9.2 depending on desired design: – SDI-12 or SDI-12/4 … 2 ...
measurement of groundwater and surface waters. Changes in water level are transferred via a float-cable counterweight system to the float pulley of the SE 200. The rotation caused by this action is converted to an electrical signal that is available at the connecting line. The SE 200 is available with a 4 … 20 mA interface or with a combined 4 … 20 mA/SDI-12 inte ...
There are three different possible types of SE 200 installations: � as a stand-alone device � as an attachment to any mechanical level recorder: – Variant 1: Exisiting float cable is fed through the SE 200 float pulley – Variant 2: SE 200 float pulley is coupled to the float pulley of the level recorder via a carrier unit. � in a 4"; 4,5"; 5" or 6" observation well An installation set with all required parts is provided al ...
Please refer to Figures 2 + 3 and proceed as follows: Fastening the SE 200 � Attach SE 200 to connection angle B (M 6 x 16 + washers); attach connection angle B to a flat base with double-sided adhesive strips (if necessary: use screws in addition). Alternatively: Attach the SE 200 directly to a suitable vertical mounting wall using M 6 x 25 screws and washers. Installing the float, float cable and counte ...
The SE 200 contains an SDI-12 interface or a combination SDI-12/4 … 20 mA interface depending on the conditions of delivery. These interfaces allow one to connect the SE 200 both to the OTT datalogger and to any datalogger by another manufacturer that has the correct interfaces. The SDI-12 interface must meet SDI-12 Standard 1.2 (SDI-12 = Serial-Digital Interface with 1200 baud). The interfaces of the SE 200 are available on a 4-w ...
interface � Connect the SE 200 as shown in Figure 5 to the to the LogoSens 2 Station Manager using the connecting cable. Please follow the LogoSens 2 Station Manager operating instructions as well. Configuring the LogoSens 2 for SE 200 with the SDI-12 interface � Create a LogoSens 2 channel using the SDI-12 Master function block (Serial sensors tab). � Apply the following settings: � Termi ...
interface � Connect the SE 200 as shown in Figure 7 to the LogoSens 2 Station Manager using the connecting cable. Please follow the LogoSens 2 Station Manager operating instructions as well. Configuring the LogoSens 2 for SE 200 with the 4 … 20 mA interface � Create a LogoSens 2 channel using the I 4-20 mA function block (Analog Sensors tab). � Apply the following settings: � Terminal b ...
Rotational direction definition Example: The float pulley rotates clockwise SE 200 with rotational direction to the “left“ → decreasing measured values SE 200 with rotational direction to the “right“ → increasing measured values Adjusting the rotational direction for an SDI-12 interface You can alternate between level and depth measurement using the SDI-12 com- mand “Change R ...
6.1 Standard commands
The following SDI-12 standard commands are implemented in the SE 200:
Command
Answer
Description
a!
a
aOPA
(4 … 20 mA interface) The load resistance connected to the SE must not exceed a specific maximum value. This value depends on the level of the supply voltage to the SE 200. If the load resistance is greater, the output current can no longer be evaluated. Smaller load resistances are allowed. � Read off the maximum load resistance for your supply voltage from the following diagram. Example: Supply voltage 18 Volts ...
the float and counterweight hang freely. To buffer the loss of operating voltage, the SE contains a lithium battery. This lithium battery has a lifespan of at least 10 years1). The SE 200 is also functional after 10 years provided that the operating voltage is applied uninterrupted. In order to maintain buffer operation when the operating voltage fails, we recom- men ...
Measuring range SDI-12 ±30 m; ±98.424 ft 4 … 20 mA 0 … 1 m; 0 … 10 m; 0 … 30 m 0 … 3 ft; 0 … 30 ft; 0 … 90 ft Resolution SDI-12 0.001 m; 1 cm; 0.001 ft 4 … 20 mA 0.1 % of the measuring range Precision 1) SDI-12 ± 0.003 % of the measuring range ± 1 digit 4 … 20 mA 0.1 % of the measuring range Units SDI-12 m; cm; ft Interfaces SDI-12 or SDI-12/4 … 20 mA Supply voltage 9 to 30 V DC Current drawn SDI-12 Sleep mode < 40 ...
Figures 10 through 15 indicate examples of attachment options to mechanical level recorders. Each illustration indicates the parts of the installation accessories used. Select the illustration that applies to you and proceed as follows: Fastening the SE 200 � When using a carrier unit (Figure 14 + 15): Fasten the carrier rail to the float pulley of the SE 200 using two recessed-head bolts; attach the car ...
friction disc M 6 x 25 + washer (2 x) SE 200 Guide lever, short Guide lever, long to datalogger Fig. 11: Attachment example to OTT strip chart recorder R20. Additional float cable guide via SE 200 float pulley. Use the short guide lever for a standard R 20 and the long guide lever for an R 20 with bracket (dashed lines). Tighten the guide roller screw only slightly! Required parts: Connecting angle A + friction disc Guide roller 18 ...
friction disc M 6 x 25 + washer (2 x) SE 200 Guide roller + M 6 x 18 to datalogger Connecting angle A + friction disc M 6 x 25 + washer (2 x) SE 200 Guide roller + M 6 x 18 to datalogger Fig. 13: Example of attachment to strip chart recorder from another manufacturer. Additional float cable guide via SE 200 float pulley. Tighten the guide roller screw only slightly! Required parts: Connecting angle A + friction disc Guide roller Fig. 1 ...
carrier pin Connecting angle B + M 6 x 25 Carrier rail Carrier base + carrier pin Fig. 14: Attachment example to the vertical drum recorder of a different manufacturer. Coupling the SE 200 using the carrier unit, consisting of a carrier rail, carrier base and carrier pin. Attach the carrier base to the float pulley so that it can rotate without blockage. Required parts: Connecting angle B Carrier rail Carrier base Carrie ...
Related Devices for OTT SE 200:
User Manual .;ri..' @arr,'} . FHOIO .aaFrt rs trTT svtt,Bosktii -rl I i .1i, lrr:::1:l@ User handbook for the OTT MXQ Set-top boxes. This manual covers power management, operating modes, system setup, product handling.
English Technical Description Rain Gauge Pluvio with Pulse Output User instructions for the OTT Pluvio Measuring Instruments. This guide includes application scenarios, maintenance schedule, service contacts.
DOC026.98.80211 MF pro 06/2015, Edition 6 Basic User Manual Basis-Bedienungsanleitung Manuale di base dell'utente Manuel d'utilisation de base Manual básico de Device user manual for the OTT MF pro Measuring Instruments. This guide explains the features and menu navigation, troubleshooting guides, power management, repair references.
English Operating instructions Pressure Probe OTT PLS Detailed product documentation for the OTT PLS Test Equipment. The document provides guidance on safety and usage examples, setup guidelines, internal layout.
TT TV BOX 4X CPU Cortex-A5 4X GPU Mali-450 User Manual Android 4.4 KitKat H.264 1080P Encoder MXQ is the new generation of MX OTT TV BOX Operation guide for the OTT MXQ Set-top boxes. The guide explains operation and setup tips, firmware updates, operational guidelines.
DOC026.53.80211 MF pro 09/2018, Edition 7 Operating Instructions Product usage manual for the OTT MF pro Measuring Instruments. It provides guidance on component replacement, setup tips, performance guidelines, troubleshooting.
Operating instructions UV Nitrate Sensor OTT ecoN English Setup instructions for the OTT ecoN Kitchen Appliances. This documentation explains configuration and configuration options, menu navigation, operational guidelines, replacement parts.
English Operating instructions Shaft Encoder OTT SE 200 Comprehensive operating guide for the OTT SE 200 Media Converter. It provides detailed operation instructions and device overview, shutdown procedures, calibration steps, application scenarios.
Media Converter: Frequently Requested PDF Instructions
Critical Release Notice Publication number: 297-8211-550 Publication release: Standard 05.02 The content of this customer NTP supports the SN06 (DMS) and ISN06 Official user handbook for the Nortel DMS-100 Wireless Access Point. It provides information on installation and cleaning instructions, safety information, technical troubleshooting.
Before operating this unit, please read this Owner's Manual carefully GOODMANS HELPLINE 0870 8730080 Device technical manual for the Goodmans 1790S Media Converter. The manual provides information on troubleshooting guides, user settings, installation steps.
HDMI to 3G/HD/SD-SDI Converter with Audio Embedder User Manual rev: 180607 Made in Taiwan CV-53A Technical guide for the GoMax Electronics CV-53A Media Converter. This manual elaborates on user settings, technical assistance, operational safety, product specifications.
Quick reference guide for the Siemens ISOLATED MULTI-DROP SG-6048-01 Media Converter. The manual provides technical details on operation, user instructions, hardware components.