Monark 828E Manual
Text of Monark 828E Manual
© 2008 MONARK EXERCISE AB, Vansbro, Sweden
Contents
3
Monark Exercise AB
4
Product Information
5
Operating Instruction
6
Workload device
6
Cycle adjustments
6
Computer specifications
7
Computer Instruction
7
Service
8
Warranty
8
Service check & maintenance
8
Transport
8
Batteries
9
Replacement of brake belt
9
Brake belt contact surface
10
Crank bearing
10
Flywheel bearing
10
Chain 1/2“ x 1/8“
11
Scale - zero adjustment
Monark Ergomedic 828 E
4
Monark Exercise AB
Monark Exercise AB
Monark has 100 years’ experience of bicycle production. The Monark tradition
has yielded know-how, experience, and a real feel for the product and quality. Since
the early 1900s, Monark’s cycles have been living proof of precision, reliability,
strength and service. That is one of the reasons why we are now the word lead-
er in cycle ergometers and the market leader in Scandinavia in transp
Monark Ergomedic 828 E 5
Product Information
Product Information
Congratulations on your new Ergometer.
The Monark 828 E is the world’s most commonly
used exercise ergometer. The adjustable brake sys-
tem and the force can be set and read Kiloponds
(kp) and Newton (N). The actual brake power is
showed in Watts on the electronic meter.
The cycle is equipped with an electronic meter
showing pedal revulotions per minute (RPM),
heart rate in bpm (HR), exerc
Monark Ergomedic 828 E 6
Operating Instruction
Operating Instruction
Workload device
The 828 E uses a brake belt system to control
the resistance. The brake power can be changed
by increasing or decreasing the tension of the
brake belt against the tension knob(1). See fig:
Workload device.
Cycle adjustments
Seat height should be adjusted to a comfortable
position. A suitable height is when your knee is
slightly bent and the middle of the foot is straight
Monark Ergomedic 828 E 7
Operating Instruction
Display
RPM
0 - 250
rev./min
HR
50 - 240
bpm
TIME
0:00-99:59
min:sec
SPEED
0 - 99
km/h or mph
DISTANCE
0.0 - 99.9
km or mile
FORCE
0.0 - 7.0
kp
CALORIES
0 - 999
kcal
WATT
0 - 7 x rpm watt
Computer specifications
Batteries:
1.5 V x 2
R6 (AA)
Storing temp.:
-10ºC - +60ºC
Operating temp.:
0ºC - 50ºC
Computer Instruction
Press any button or move the pedal to turn on the
meter. At the display for heart rat
Monark Ergomedic 828 E 8
Service
1
Service
Warranty
As on any quality product there may be an ex-
ceptional fault due to material or manufacture.
If such a fault should arise on your Ergometer,
contact your place of purchase to inquire about
repair.
Monark products and parts are guaranteed
against defects in materials and workmanship
for a period of one year from the initial date of
purchase of the unit.
Parts found to need replacement due to normal
wear a
Monark Ergomedic 828 E 9
Service
1
2
Fig: Batteries
1) Batteries
2) km/mile
Batteries
The batteries are in a separate package at deli-
very. The batteries may need to be replaced upon
assembly. To replace the batteries at any time,
take the meter out of the housing by bending up
in the lower end with a coin or similar. The bat-
teries, 2 x 1.5V size AA(R6), which are placed in
the holder on the backside of the meter, can then
easily be changed. See fig: B
Monark Ergomedic 828 E 10
Service
Crank bearing
The crank bearing is long term greased and needs
normally no supplementary lubrication. If pro-
blem arises, please contact your Monark dealer.
Flywheel bearing
The bearings in the flywheel are lifetime greased
and require normally no maintenance. If problem
arises, please contact your Monark dealer.
Brake belt contact surface
The brake belt should be regularly checked to en-
sure that it has not suffered exc
Monark Ergomedic 828 E 11
Service
Chain 1/2“ x 1/8“
It is strongly recommended to keep the chain
clean. Dirt build-up on the chain will cause ex-
cess wear. A chain lubricant and solvent for nor-
mal road bikes may be used.
Check the lubrication and tension of the chain in
regular intervals. In the middle of its free length
the chain should have a minimum play of 10 mm
(1/4in). See fig: Chain adjustments. When the play
in the chain is about 20 mm (3/4
Monark Ergomedic 828 E 12
Service
1
3
2
9
Fig: Scale adjustment
1) Locking nut
2) 0-index
3) Adjustment weight, pendulum
Fig: Adjustment kp-scale window
9) Lock screw f. scale indicator
4
5
7
8
6
Fig: Calibration
4) Calibration weight, 4kg
5) kp-scale
6) Attachment of calibration weight
7) Pendulum at 4kp
8) Screw to adjustment weight
Calibration
Although all Ergometers are calibrated at the fac-
tory the user may wish to verify this by perfor-
ming a mech
Monark Ergomedic 828 E 13
Service
Freewheel sprocket
When replacing the freewheel sprocket remove
left and right frame cover. Dismantle the chain as
described in part ”Chain 1/2” x 1/8” ”.
Loosen the axle nuts and lift off the flywheel.
Remove the axle nut, washer, chain adjuster and
spacer on the freewheel side. Place the special
remover (part No. 9100-14) in the adapter and
place the spacer and axle nut outside. See fig:
Special remover.
NOTE: D
Monark Ergomedic 828 E 14
Spare parts
Spare parts
3
6
5
4
1
29
30
31
32
33
34
35
36
37
2
6
3
26
25
27
28
24
23
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Pos.
Qty.
Art.No.
Description
Pos.
Qty.
Art.No.
Description
1
1
9301-15
Support tube, front
20
1
9300-115
Bushing f. saddle post
2
1
9301-16
Support tube, rear
21
1
9300-123
Top cover
3
4
9328-51
Plastic cap, blue
22
1
9300-280
Handlebar complete
4
4
9328-26
Rubber foot
23
1
9100-180
-Lever M8
5
1
93
Monark Ergomedic 828 E 15
Spare parts
12
14
13 15
2
31
1
3
9
5
4
7
3 10 8
17
6 25 26 20 18 37
16
11
24
21
35
34
22
33
23
24
20
27
18
18
37
19
36
31
32
30
29
28
Pos.
Qty.
Art.No.
Description
Pos.
Qty.
Art.No.
Description
1
1
9300-30
Frame for equipment
18
3
5866
Washer
2
4
9300-21
Screw MVBF 6x16 mm
1
9300-36
Meter panel, complete
4
5863
Washer
19
1
9339-100
-Meter panel
3
5
5843-9
Nut M6
20
2
9000-17
-Spacer
4
1
9300-22
Tension lever
21
1
9300-93
Monark 828E
Notes:
.............................................................................................................................................................
.............................................................................................................................................................
.........................................................................................................................................
© 2008 MONARK EXERCISE AB, Vansbro, Sweden Contents
3
Monark Exercise AB
4
Product Information
5
Operating Instruction
6
Workload device
6
Cycle adjustments
6
Computer specifications
7
Computer Instruction
7
Service
8
Warranty
8
Service check & maintenance
8
Transport
8
Batteries
9
Replacement of brake belt
9
Brake belt contact surface
10
Crank bearing
10
Flywheel bearing
10
Chain 1/2“ x 1/8“
11
Scale - zero adjustment
Monark Ergomedic 828 E 18
Monark Exercise AB
Monark har 100 års erfarenhet av cykeltillverkning. En tradition som gett kunskap,
erfarenhet, och känsla för produkt och kvalitet. Sedan början av 1900-talet har Mo-
narks cyklar varit ett levande bevis på exakthet, pålitlighet, hållfasthet och service.
Det är en av anledningar till att vi idag är världsledande på Ergometercyklar och
marknadsledande i Skandinavien på Transportcyklar.
Vi tillverkar,
Monark Ergomedic 828 E 19
Produktinformation
Vi gratulerar till din nya motionscykel.
Monark Ergometercykel modell 828E är en test-
cykel, försedd med en broms, vars bromskraft
kan avläsas i Newton (N) eller i kilopond (kp).
Bromseffekten kan direkt avläsas i watt på den
elektroniska mätaren när den rätta bromskraf-
ten ställts in. Den energi som en person måste
utveckla under en viss tid för att övervinna
denna bromseffekt, kan därigenom ber