On-Board Weighing System

Calibration RDS Part No.: Document Issue: Software Issue: S/DC/500-10-576 1.31: 20/10/08 PS312-002 rev. 03 (LM8000i) PS313-002 rev. 03 (LM800i) ...

Electromagnetic Compatibility (EMC)

This product complies with Council 2004/108/EC when installed and used in accordance with the relevant instructions. Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax +44 (0) 1453 733311 for further information. Our policy is one of continuous improvement and the information in thi ...

1 – CALIBRATION SUMMARY

1 CALIBRATION SUMMARY ______________________________________________ 4 2 LOADMASTER 800I/8000I - COMMON CALIBRATION_____________________ 5 2.1 Sensor Setup _________________________________________________________________________ 5 2.1.1 General setup for loading shovels .............................................................. ...

1 – CALIBRATION SUMMARY

4 1 Calibration Summary The LM 800i/8000i system operates in a Non-Approved weighing mode. Dynamic or Static weighing is possible. The system is designed to be easily upgradable for Weights and Measures approved operation, either for automatic weighing (AWI) or non-automatic weighing (NAWI). There are a large number of functions wit ...

2 - LM800/ 8000 COMMON CALIBRATION

5 2 Loadmaster 800i/8000i - Common Calibration 2.1 Sensor Setup Sensor setup should be done before any other calibration. The sensor settings apply regardless of which attachment is selected. Select the 'Sensor Setup' screen (figure. 2). *Default Factory PIN = 4084 "No. of samples" is the number of times the instrument t ...

2 - LM800/ 8000 COMMON CALIBRATION

6 “Sample type” : “STD” sets the system to sample a dynamic weigh procedure in the standard format, as used in the Loadmaster 8000 series with earlier S/W version PS300-026 rev.38 “ADV” sets the system to sample a dynamic weigh procedure in a new format. This mode should generally be selected, as it should be ...

2 - LM800/ 8000 COMMON CALIBRATION

7 2.2 Auto Cal After "Sensor Setup", do an "Auto Cal". The instrument will automatically advance from Auto Cal step 1 (Diff. Setup) to step 5 (Cal Weight). You can however, still select from the Auto Cal menu in any order. 2.2.1 Dyn. Diff. Setup This function is active only when the "Dual Sensor" setting on the "Sensor ...

2 - LM800/ 8000 COMMON CALIBRATION

8 Slow Speed calibration 1. With the menu pointer opposite the symbol, lower the bucket then slowly lift through the weighing position again. If you lift too quickly, the display will flash 'Error'. If so, lower the bucket and try again. The instrument will bleep once, then display the frequency output of each pr ...

2 - LM800/ 8000 COMMON CALIBRATION

9 2.2.6 Zero 1. Lift the empty bucket at maximum speed. The instrument will bleep once when the weight is taken. ENTERING to set "Dynamic Zero" is automatic. 2. Lift the bucket to the weighing position. The instrument will bleep twice. ENTERING to set "Static Zero" is automatic. 3. Press the "ESC" key to continue AUTOCA ...

2 - LM800/ 8000 COMMON CALIBRATION

10 2.2.8 Angle Calibration (optional) NOTE: All factors in the "Angle Factors" screen should be manually set to zero (except the Alarm Threshold Angle which is 10° by default) before carrying out the angle calibration. This is especially important if you have to recalibrate the angle compensation, after ...