Parweld XTM303C Operator's Manual
Text of Parweld XTM303C Operator's Manual
Thank you and congratulations on choosing Parweld. This Owner’s Manual is designed to help you get
the most out of your Parweld products. Please take time to read the Safety precautions. They will
help you protect yourself against potential hazards in the workplace. With proper maintanance this
equipment should provide years of reliable service. Al
1.0 Safety precautions
4
2.0 product description
5
3.0 Technical Specifications
6
4.0 Description of controls
6
5.0 Installation
7
5.1 Unpacking the Machine
7
5.2 Location
7
5.3 Input and grounding connection
7
5.4 Output Polarity Connections
7
5.5 Changing drive roll sets
7
5.6 Welding wire installation
7
5.7 Torch installation
8
5.8
1.0 Safety precautions
eleCtrIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks or severe burns.
The electrode and work circuit is electrically live whenever the output
is on. The input power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding,
the wire, wire
WELDING can cause fire or explosion.
Remove all flammables within 10m of the welding arc. If this is not
possible, tightly cover them with approved covers.
Do not weld where flying sparks can strike flammable material.
Protect yourself and others from flying sparks and hot metal.
Be alert that welding sparks and hot materials from welding c
3.0 Technical Specifications
The XTM 303C is a compact type machine with integrated wire feed
unit for use with 3 phase 400V supply.
Feature
XtM303C
Input voltage
400V +/-10%
Hz
50
phases
3
Current Draw
(a)
12
Fuse
rating
(a)
16
Output current
(a)