Thank you for purchasing a Sanyo Autoclave.

Please read this instruction manual carefully before using the product. After reading this manual, store it in a readily accessible place along with the warranty card. Please pay particular attention to the � Safety Precautions � section on page 1 to 6. • • Contents Page How to Use On Power F ...

• Read these � Safety Precautions � carefully before use so as to use the product properly.

• Be sure to observe the precautions without fail as they are intended to ensure the safe use of the product, protect you and other people against hazards, and prevent loss of and damage to property. The indications and meanings of each category ...

Ground the product without fail.

In the event of trouble, stop operation and turn OFF the power. The product should never be disassembled or repaired by any other person than a qualified service engineer. Failure to observe this warning may result in fire, malfunction or injury. Before draining off heating water, open the cover for at least 2 hours a ...

Failure to observe this warning may result in accident

or incomplete sterilization. Failure to observe this warning may destabilize control of the product or result in incomplete sterilization. If the containers are placed with their openings facing upward, it is hard for air to sufficiently escape from the container and for steam to sufficiently pen ...

Connect power cord of the product

to its own dedicated outlet. Nothing should be placed on the power cord. Do not use staples or nails to anchor the power cord. Be sure to wear thermally insulated leather gloves. Note that it takes time until liquid is cooled down. Handling a sterilized object with bare bands immediately after the end of operation m ...

Failure to observe this caution may result in burns,

electric shock or injury. Keep away from the safety valve vent. Your fingers may be pinched and injured. Insert the hose securely. Be careful about the position of the exhaust hose insertion holes. Be sure to insert the hose in the tank into the holes at the back inside the exhaust tank. Failure to ...

Hold the grips when moving the product.

Install the product on a level surface. Drain off heating water everyday after use of the product. Do not move the product with the exhaust tank full of water. If trouble is indicated on the process display, set the power switch in the � OFF � position. Do not wet the product. Tip-resistant metal ...

Use of well water, saline water, etc. may cause trouble.

Do not use the product for anything other than the intended purposes of sterilization, heat-retention and melting. Failure to observe this caution may corrode the chamber or clog the piping. (Do not use the product as a cooking heater.) Corrosion of the chamber ...

: 0 ~ 3000m

Voltage fluctuation : ±10% of nominal voltage • Product environment and conditions of use Location : Indoor Ambient temperature : 5 ~ 40°C Relative humidity : 50 ~ 80% • The boiling point must be set for the product according to the altitude of the location where the product is installed. The boiling point has been ...

on the rear side

Tank mounting bracket Rear side Handle Use for opening/closing the cover. Steam is discharged through this port if pressure in the chamber rises abnormally. Movable handle Used for unlocking the cover. The cover can be unlocked by pressing this handle down and pulling toward you. Pressure gauge Indicates the pressure inside the ...