Zonex SubZone Manual 

Text of the manual

W I R E L E S S T H E R M O S T A T

Stand-Alone or Floating Zone Modulating Damper Controlled with Auto Changeover Programmable SUBZONE OVERVIEW The system is designed for over-conditioned areas and prevents over-heating and over-cooling of individual or stand alone zones. The SubZone is a battery powered auto changeover programmable thermostat tha

Stand-Alone Modulating Damper

Controlled with Auto Changeover Programmable Wireless Thermostat W I R E L E S S T H E R M O S T A T WIRING INSTALLATION INSTRUCTION SubZone INSTALLATION 1. Install Wireless SubZone Round, Rectangular or D-FUSER Damper into the supply air duct. (Ref. Part # WST Round, WCD Rectangular WxH, WD-FUSER) 2. Install a 24 volt,

Pressing any button on the SubZone Wireless Thermostat

will wake up controller providing current information about system operations. Using the Up and Down button, select your required setpoint: UP - Increases set point, additionally this button is used to configure time and date, set schedule. DOWN - Decreases set point, add

PROGRAMMING AND SETUP INSTRUCTIONS

Install AA batteries into the SubZone Wireless Thermostat. Mount the SubZone Wireless Thermostat in the zone on an interior wall away from direct sunlight, supply air currents or any heat generating source. SubZone wireless thermostat needs to be mounted within 100 feet of SubZone control board. On the SubZone damper locat

Stand-Alone Modulating Damper

Controlled with Auto Changeover Programmable Wireless Thermostat W I R E L E S S T H E R M O S T A T BATTERY INSTALLATION/REPLACEMENT The SubZone Wireless Thermostat requires two AA batteries. When the battery ICON on SubZone wireless controller indicates batteries are low, replacement of batteries i

More Zonex Thermostat Owners Instructions: