www.sun.com Submit comments about this document at: http://www.sun.com/hwdocs/feedback Sun Fire™ E2900 Systems Installation Guide Part No. 817-4053-15 May 2006, Revision A all-guides.co m ...
Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries. This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and decompilation. No part ...
xi Safety Agency Compliance Statements xv Preface xxvii 1. Physical Installation 1–1 1.1 Installing Slides and Rails 1–2 1.1.1 Adjusting the Rail Assembly 1–3 1.1.2 Installing the Inner Slides on the System 1–4 1.1.3 Preparing the Rails for Two-Post Installations 1–6 1.1.4 Installing the Rail Assemblies in a Sun Fire/StorEdge Cabinet 1–7 1.1.4.1 Installing the Rail Assemblies in the Bottom Position 1–7 1.1.4.2 Installing the Rail Assemblies in the Top Position 1–8 1.1.5 Installing the Rail Assemblies in a Sun Rack 900 Cabinet 1–9 1.1.5.1 Installing the Rail Assemblies in the Bottom Positio ...
1.2.1 Preparing to Install the System in the Cabinet 1–13 1.2.2 Mounting the System in the Cabinet 1–15 1.3 Installing Slide Rail Locking Nuts 1–19 1.4 Installing the Cable Management Arm 1–21 1.4.1 Installing the CMA–Lite 1–22 1.4.2 Installing the CMA–800. 1–23 1.5 Connecting Sun Fire V1280/Netra 1280 Power Cables 1–30 1.6 Connecting Consoles to the System Controller 1–32 1.6.1 Connecting the Initial Administrative Console 1–33 1.6.2 Connecting the Administrative Console 1–35 1.7 Connecting the I/O Assemblies 1–35 1.8 Powering On the System 1–35 1.9 Powering Off the ...
A–9 A.6 Net0/Net1 Ethernet Ports A–10 ...
1–3 FIGURE 1-2 Spring Clips and Cutouts 1–5 FIGURE 1-3 Rail Assembly (Modified for Two-Post Installation) 1–6 FIGURE 1-4 Installing the Rails in a Sun Fire Cabinet 1–8 FIGURE 1-5 Installing the Rails in a Sun Rack 900 Cabinet or 19-Inch Four-Post Cabinet 1–10 FIGURE 1-6 Releasing the Door Hinge Mechanism 1–13 FIGURE 1-7 Removing the Shipping Cradle Bolts 1–14 FIGURE 1-8 Inserting the Lifting Device into the Shipping Cradle 1–15 FIGURE 1-9 Aligning the Slides 1–16 FIGURE 1-10 Removing the Shipping Cradle 1–17 FIGURE 1-11 Pushing the System into the System Cabinet 1–18 FI ...
FIGURE 1-21 Attaching Left Hand T-Bracket 1–27 FIGURE 1-22 Attachment of Right-Hand T-Bracket 1–28 FIGURE 1-23 Attachment of Upper/Lower CMA Arms to T-Bracket 1–29 FIGURE 1-24 System Controller and I/O Assembly Locations 1–34 FIGURE A-1 External I/O Connections—Sun Fire V1280/Netra 1280 Systems (Rear View) A–1 FIGURE A-2 68-Pin SCSI Connector A–3 FIGURE A-3 DB-15 (Male) Alarms Service Port Connector A–5 FIGURE A-4 RJ-45 Serial Connectors A–6 FIGURE A-5 RJ-45 TPE Socket A–9 FIGURE A-6 RJ-45 Gigabit Ethernet Connectors A–10 ...
A–3 TABLE A-2 68-Pin SCSI Connector Pinout (continued) A–4 TABLE A-3 Alarms Service Port Connector Pinout A–5 TABLE A-4 RJ-45 Serial Connector Pinout A–6 TABLE A-5 Default Settings for Connecting to Serial A A–7 TABLE A-6 Pin Interconnections Performed by the Sun DB-25 Adapter A–7 TABLE A-7 Pin Interconnections Performed by a DB-9 (9-pin) Adapter A–8 TABLE A-8 Twisted-pair Ethernet Connector Pinout A–9 TABLE A-9 TPE STP-5 Cable Lengths A–9 TABLE A-10 RJ-45 Gigabit Ethernet Connector Pinout A–10 ...
Your Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital Equipment (ICES-003) — Canada • Voluntary Control Council for Interference (VCCI) — Japan • Bureau of Standards Metrology and Inspection (BSMI) — Taiwan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product. FCC Class A Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful inter ...
ICES-003 Class A Notice - Avis NMB-003, Classe A This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. ICES-003 Class B Notice - Avis NMB-003, Classe B This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. ...
xiii BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label. GOST-R Certification Mark T33012 ...
Statements Read this section before beginning any procedure. The following text provides safety precautions to follow when installing a Sun Microsystems product. Safety Precautions For your protection, observe the following safety precautions when setting up your equipment: ■ Follow all cautions and instructions marked on the equipment. ■ Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the equipment’s electrical rating label. ■ Never push objects of any kind through openings in the equipment. Dangerous voltages may be present. Conductive foreign objects could pr ...
SELV Compliance Safety status of I/O connections comply to SELV requirements. Power Cord Connection Caution – Sun products are designed to work with power systems having a grounded neutral (grounded return for DC-powered products). To reduce the risk of electric shock, do not plug Sun products into any other type of power system. Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building. Caution – Not all power cords have the same current ratings. Household extension cords do not have overload protection and are not meant ...
xvii Caution – To prevent extreme operating temperature within the rack insure that the maximum temperature does not exceed the product’s ambient rated temperatures. Caution – To prevent extreme operating temperatures due to reduced airflow consideration should be made to the amount of air flow that is required for a safe operation of the equipment. Laser Compliance Notice Sun products that use laser technology comply with Class 1 laser requirements. CD and DVD Devices The following caution applies to CD, DVD, and other optical devices. Caution – Use of controls, adjustments, or the performance of procedures ...
Selon le type d'interrupteur marche/arrêt dont votre appareil est équipé, l'un des symboles suivants sera utilisé: Marche – Met le système sous tension alternative. Arret – Met le système hors tension alternative. Veilleuse – L'interrupteur Marche/Veille est sur la position de veille. Modification du matériel N'apportez aucune modification mécanique ou électrique au matériel. Sun Microsystems décline toute responsabilité quant à la non-conformité éventuelle d'un produit Sun modifié. Positionnement d’un produit Sun Attention – Evitez d'obstruer ou de recouvrir les ori ...
xix Mise en garde relative aux batteries Attention – Les batteries risquent d’exploser en cas de manipulation maladroite ou de remplacement incorrect. Pour les systèmes dont les batteries sont remplaçables, effectuez les remplacements uniquement selon le modèle du fabricant ou un modèle équivalent recommandé par le fabricant, conformément aux instructions fournies dans le manuel de service du système. N’essayez en aucun cas de démonter les batteries, ni de les recharger hors du système. Ne les jetez pas au feu. Mettez-les au rebut selon les instructions du fabricant et conformément à la législation ...
Einhaltung sicherheitsbehördlicher Vorschriften Lesen Sie vor dem Ausführen von Arbeiten diesen Abschnitt. Im folgenden Text werden Sicherheitsvor- kehrungen beschrieben, die Sie bei der Installation eines Sun Microsystems-Produkts beachten müssen. Sicherheitsvorkehrungen Treffen Sie zu Ihrem eigenen Schutz bei der Installation des Geräts die folgenden Sicherheitsvorkehrungen: ■ Beachten Sie alle auf den Geräten angebrachten Warnhinweise und Anweisungen. ■ Stellen Sie sicher, dass Spannung und Frequenz der Stromversorgung den Nennleistungen auf dem am Gerät angebrachten Etikett entspre ...
Server PDF Instructions
ThinkServer Garantie en ondersteuning Machinetypen: 3719, 3724, 3729, 3779, 3795, 3796, 3797, 3798, 3808, 3809, 3815, 3817, 3818, 3819, 3821, 3822, 3823, 3824, 3826 en 3836 Official user handbook for the Lenovo ThinkServer TD200 Server. This documentation highlights features and calibration steps, component replacement, hardware instructions.
G262-ZR0 HPC Server - 2U DP SXM4 A100 4 GPU Server User Manual Rev. 1.0 User guidebook for the Gigabyte G262-ZR0 Server. This manual details technical troubleshooting, daily usage, supported accessories.
LOGO! CMR2020 / LOGO! CMR2040 ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ __________ Complete installation manual for the Siemens LOGO! CMR2020 Control Unit. This manual describes setup, usage, and control functions, connectivity options, daily usage.
hewlett-packard sa3000 series vpn client release 6.8.2 release notes Hewlett-Packard Company HP: 5971-0874 P/N: A52439-001 March 2001 Service and user manual for the HP Sa3110 - VPN Server Appliance Server. This manual covers installation, operation, and operational guidelines, troubleshooting guides, service instructions, testing procedures.