WARNING • Always disconnect a power supply of Air-Water Heat Pump before servicing it or accessing components inside the unit. • Verify that installation and testing operations shall be performed by qualif

Installing the unit

Deciding on where to install the unit f f Install the unit in indoor and do not install it outside. The unit is designed only for indoor. f f Direct heat can make the kit have some failures in operation. f f Choose locations that are dry and sunny, but not exposed to direct sunlight or strong winds. f f Choose location where p

3. Seal the service entrance for the remote controller cable with putty

to prevent possible invasion of dew drops, water, cockroaches or insects. [A] For installation in the switch box [B] For direct installation on the wall, select one of the followings: • Prepare a hole through the wall to pass the remote controller cable (in order to take ou

Power and communication with outdoor unit

Communication Wire Power Wire Connecting the power wire 1. Connect ‘Live’ and ‘Neutral’ power line with ‘pin #1’ and ‘pin #2’ in TB-A. 2. Connect ‘Protective Earth’ line with ‘Earth screw’ in case. Recommended wire specification Load Power Supply Power Cable Max. Length Type GL mm2

Connecting heater wire (in the case of resistor heater which is under 3kw)

1. Directly connect ‘Booster heater’ with ‘pin #3 and pin #4’ in TB-A. f f If you use separated ‘Thermal fuse’, connect ‘Thermal fuse’ with ‘HEATER THERMO’ connector. • Wire spec : 4.0 mm2 • MLCC spec : 30A NOTE Connecti