Simpson 150-2 Operator's Manual

Brand: Simpson
Category: Multimeter
Model: 150-2 (Operator's Manual)
File Type: PDF
File Size: —
Pages: 16
Text of Simpson 150-2 Operator's Manual

Simpson 150-2 About this Manual

To the best of our knowledge and at the time written, the information con- tained in this document is technically correct and the procedures accurate and adequate to operate this instrument in compliance with its original ad- vertised specifications. Notes and Safety Information This Operator’s Manual contains warning symbols which alert the user to check for hazardous conditions. These appear throughout this manual where applicable,

Simpson 150-2 SHOCK HAZARD: As defined in American National Standard, C39.5, Safety

Requirements for Electrical & Electronic Measuring & Controlling Instrumen- tation, a shock hazard shall be considered to exist at any part involving a potential in excess of 30 volts RMS (sine wave) or 42.4 volts DC or peak and where a leakage current from that part to ground exceeds 0.5 milliampere, when measured with an appropriate measuring instrument defined in Sec- tion 11.6.1 o

Simpson 150-2 Items And Accessories .......................................................................7

1.2 Safety Considerations ........................................................................ 7 1.3 Technical Data ....................................................................................7 2. INSTALLATION ..............................

The Simpson 150-2 Amp-Clamp (hereafter referred to as the 150-2 or the

Amp-Clamp) allows current measurements without breaking the current line and interrupting the working appliance under test. In effect, the 150-2 works as a transformer, containing a split core for accommodation of the current conductor under test. The transformer split core is made of two sections, hinged at one end, and pivoted so that it can be attached around the

These amp clamps are calibrated for opera-

tion on 60 Hz circuits, however, they can be calibrated for operation on 50 Hz circuits or other frequencies on special order. EFFECT OF CONDUCT OR POSITION: The effect of moving current conductor from center to any position within core jaws: �3%. TEST CONDUCTOR SIZE CHECK: Round wires and buss bars, 1-1/8 inch maximum outside diameter. Rectangular and square-shaped conductors to 1 inch s

The following contains instructions for installation and shipping of the 150-2.

Included are unpacking and inspection procedures, warranty, shipping and care. 2.1 Unpacking And Inspection Examine the shipping carton for signs of damage before unpacking. If un- damaged unpack the instrument and inspect it for possible damage. Check that all furnished items and accessories are included (Table 1-2). Check the electrical performance as soon

CONTROLS AND CONNECTORS

All operating and adjustment controls and connectors are described in this section, along with a list (Table 3-1) describing their functions. Become famil- iar with each item before operating the Amp-Clamp. Table 3-1. Controls and Connectors RANGE SELECTOR SWITCH: The range selector switch has six positions. Each position is marked for two AC current ranges. The two current ranges selected are indicated in a re- cessed sec

Simpson 150-2 This section contains information required to operate the Instrument in a safe

and proper manner. Amp-Clamp core and circuit housings are made of high quality insulating material and designed to hold the stresses of daily service involvements. BE EXTREMELY CAREFUL WHEN MEASURING HIGH MAGNITUDE CUR- RENTS OR APPROACHING WIRES OR APPLIANCES CARRYING HIGH POWER LINE VOLTAGES. 4.1 AC Current Measurements : 1. Before starting measurements, conne

Simpson Multimeter Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
8455A

User Guide: Simpson 8455A (3X3E78, Upd.06-06-2026)

15 998 190 06-06-2026
260 Series 5P

Simpson 260 Series 5P User Guide (Operator's manual), @RI93BD

21 52 13 24-08-2026
260-AFP-1

Simpson 260-AFP-1 User Guide (Handbook), @414981

19 1344 283 22-06-2026
150-2

Simpson Multimeter Operator's manual (File: PDF, 15-04-2026)

16 88 17 15-04-2026
270 series 5

Multimeter #GLN87Q

58 554 100 01-09-2026
260 series 5

Multimeter #P7N4PP

18 1322 252 06-08-2026

Multimeter: Similar Manuals