UE Systems ULTRAPROBE 201 Instruction Manual
File Specifications
| Brand: | UE Systems |
| Category: | Tools |
| Model: | ULTRAPROBE 201 (Instruction Manual), prgCaGKo5hBjo |
| File Type: | |
| File Size: | — |
| Pages: | 13 pages |
Download PDF
Download UE Systems ULTRAPROBE 201 Manual (13 pages)Read Online:
Read the UE Systems ULTRAPROBE 201 Instruction Manual online using the built-in PDF viewer.
Key Pages of Document
Warning Improper use of your ultrasonic detector may result in death or serious injury. Observe all safety precautions. Do not attempt to make any repairs or adjustments while the equipment is operating. Be sure to turn off and LOCK OUT all electrical and mechanical sources before performi ...
Monitoring bearing wear.............................................................................................. 5 Component assembly magnetic mount sensor ....................................................... ...
perception. Generically ultrasonic frequencies are considered to start at 20,000 cycles per second ( 20 kilohertz or 20 kHz). Most ultrasonic instrumentation used for equipment condition analysis includes frequencies that range from 20 to 100 kHz. ...
In a bearing, normal bearing loads cause an elastic deformation of the elements in the contact area, which give a smooth elliptical stress distribution. But bearing surfaces are not perfectly smooth. For this reason, the actual stress distribution in the contact area will be affected by a random surface roughness. In the p ...
Basic components Your kit consists of the following parts: A Grease Caddy Assembly B Clamp C Sensor Assembly – Magnetic Sensor and Cable with Acoustic Shield ...
1. Attach the Ultraprobe 201 Grease Caddy A to the grease gun, using Clamp B. 2. Connect cable from Sensor Assembly to input of Grease Caddy Before you begin testing, it is advisable to familiarize yourself with the basic components of your kit. UE Systems Grease Caddy Docking Station Mounting Instructions Docking ...
Completed setup Close up view Ready to use Keep Magnetic on Docking Station when greasing NOTE: Do not use Docking Station when using rubber or plastic tubes. ...
examine each part. On and OFF buttons. To turn the instrument ON, push the ON button in. Once pressed the instrument will stay on and then automatically turn off after 5 minutes (this will extend the battery charge and active use of th ...
operating the Ultraprobe 201 Grease Caddy. There may be times where stray signals influence the LED indicator. Using the headset will assure that the sounds being received are coming from the subject test bearing. a. Should inspections be perf ...
⚠️ Download Safety
The Tools Instruction manual (13 pages) is completely safe to download (last scan date: 13/06/2026).
Related PDF Instructions for UE Systems ULTRAPROBE 201:
-
UE Systems ULTRAPROBE 2000 Analytical Instruments Instruction manual, 28 pages
-
UE Systems 9000 Measuring Instruments Manual , 25 pages
-
UE Systems ULTRAPROBE 10,000SD Measuring Instruments Instructions manual, 10 pages
-
UE Systems ULTRAPROBE 10000 Measuring Instruments Instruction manual, 61 pages
-
UE Systems ULTRAPROBE 10000 Test Equipment Instructions manual, 6 pages
-
UE Systems Ultraprobe 100 Tools Manual , 8 pages