ZKaccess ML10R Installation Instruction
Text of the manual
Mounting Hardware Package Mounting Hardware Package
for door thickness of 39-46mm for door thickness
Note: The standard lock includes 2 mounting hardware packages only, which are used for the door
thickness of 39-46mm and 47-54 mm separately.
Note: Please refer to the above picture to adjust the direction of strike plate F and latch D.
1. Check the door thickness and prepare the corresponding mounting
hardware package.
2. Check door openi
3. Check the required backset (60mm or 70mm).
Note2: The latch has two backset options: 60mm and
70mm, please choose either one as required.
Note1: Installation template has the backset
options of both 60mm and 70mm.
4
1. New lock is configured to grant ANY Mifare card access to unlock.
2. The lock is equipped with mechanical keys for manual unlocking. Remove mechanical keys from the
package and keep them in a safe place.
3. To power up the lock, four alkaline AA batteries (not included) are required. Non-alkaline and
rechargeable batteries ARE NOT R
1. Align the template along the vertical center line of
the latch(D) at the desired handle height, and tape it
to the door.
2. Mark the holes first, and then start drilling.
E
E
D
center line of the
handle
desired handle
height
1.Drill holes on the door. 2.Install the latch (D).
Installation
6
Correct Position: T he small triangle
must be vertically upward.
This position is wrong .
B
H
C
3.Install outdoor unit(B) with gasket(C) and spindle(H) on the
door.
7