Table of Contents

Specification 2 EMC 6 Safety 7 Installation 8 Connections 9 Initial Operation 11 Manual Operation – Independent Mode 13 Manual Operation – Link Modes 21 Maintenance 22 Remote Operation 23 Remote Commands (QPX600DP only) 32 Note: The latest revisions of this manual, device drivers and software tools can be downloaded from: http://www.tti-test.com/go/qsx This manual is 48511-1460 Issue 7

General specifications apply for the temperature range 5°C to 40°C. Accuracy specifications

apply for the temperature range 18°C to 28°C after 1 hour warm-up with no load and calibration at 23°C. Typical specifications are determined by design and are not guaranteed. OUTPUT SPECIFICATIONS (Each Output) Voltage Range: Two ranges: 0V to 60V or 0V to 80V Current Range: 0.01A to 50A Power Range: Up to 600W Voltage Setting: Resolution: 1

METER SPECIFICATIONS (Each Output)

Display Type: 5-digit (Volts), 4-digit (Amps), black-on-white backlit LCD. Voltage (CI Mode and Unreg): Resolution 1mV Accuracy: 0.1% of reading ± 2 digits Current (CV Mode and Unreg): Resolution 10mA Accuracy: 0.3% of reading ± 2 digits V x A: Resolution 0·1W Accuracy: 0·5% ± 0·1W V/A: Meter shows calculated nominal V/A value, together with uncertainty range; 5 digit resolution. LOGIC CONTROL INPUT and OUTPUT (Ea

The displays (one for each output) are graphic LCDs, backlit by white LEDs; contrast is software-

controlled and can be adjusted from the keyboard. The default status displays show the VOLTS (5 digits) and AMPS (4 digits) in 12mm high characters, plus output range and status. At other times, for example during store or recall of instrument set-ups, the displays show up to 7 lines of information, instructions, or prompts. INTERFACES (QPX

TTI QPX600D EC Declaration of Conformity

We Thurlby Thandar Instruments Ltd Glebe Road Huntingdon Cambridgeshire PE29 7DR England declare that the QPX600DP & QPX600D Power Supplies meet the intent of the EMC Directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. Compliance was demonstrated by conformance to the following specifications which have been listed in the Official Journal of the European Communities. EMC Emissions: a) EN61326-1 (2006) Radiated, Cl

This instrument has been designed to meet the requirements of the EMC Directive 2004/108/EC.

Compliance was demonstrated by meeting the test limits of the following standards: Emissions EN61326-1 (2006) EMC product standard for Electrical Equipment for Measurement, Control and Laboratory Use. Test limits used were: a) Radiated: Class A b) Conducted: Class A c) Harmonics: EN61000-3-2 (2006) Class A; the instrument is Class A by product category

TTI QPX600D This power supply is a Safety Class I instrument according to IEC classification and has been

designed to meet the requirements of EN61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use). It is an Installation Category II instrument intended for operation from a normal single phase supply. This instrument has been tested in accordance with EN61010-1 and has been supplied in a safe condition. This instru

Mains Operating Voltage

This instrument has a universal input range and will operate from a nominal 115V or 230V mains supply without adjustment. Check that the local supply meets the AC Input requirement given in the Specification. Mains Lead Connect the instrument to the AC supply using the mains lead provided. Should a mains plug be required for a different mains outlet socket, a suitably rated and approved mains lead set should be used

TTI QPX600D Rear Panel Connections

Output Terminals (each output) The load should be connected to the positive (red) and negative (black) terminals marked OUTPUT. The terminals accept 4mm plugs into the end (but note that 4mm plugs will only support 30 Amps), 6mm diameter wire or plugs into the cross-hole or 8mm spade connections (with a maximum blade width of 16mm). The wiring and connectors must be capable of supporting the current required; for 50 Amp

TTI QPX600D Analogue Monitor (each output)

The output terminal voltage and output current may be monitored on V MONITOR and I MONITOR respectively. The output scaling for both is the same as that set for V CONTROL and I CONTROL, see previous section. The Analogue Monitor outputs should be connected to a measuring system with ‘floating’ inputs such as a DMM. Do not apply external voltages to these terminals. RS232 (QPX600DP only) 9−pin female D−connector wi

TTI Power Supply Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
TSX Series

Manual: TTI TSX Series (Q86M15, Upd.29-09-2026)

26 0.56 Mb 1448 232 29-09-2026
PL154

PL154 Instruction manual - 6V47VN

29 0.58 Mb 333 77 16-05-2026
EX752M

PDF User Manual (@X8G9CP), TTI EX752M Power Supply (18-09-2026)

30 634 134 18-09-2026
CPX200

TTI Power Supply Service manual (File: PDF, 29-06-2026)

30 1272 306 29-06-2026
TSX Series

TSX Series Service manual - D6P3Y4

49 1087 164 15-07-2026

Power Supply: Similar Manuals