Arcam A49 POWER / STANDBY
PHONO
PHONO
AUX
CD
TUNER
SAT
MUTE
DISPLAY
BALANCE
BD
PVR
AV
PHONES
POWER
POWER / STANDBY
SP1
SP2
POWER
POWER / STANDBY
HANDBOOK Integrated amplifier/Pre-amplifier/Power amplifier
A49/C49/P49/P349
CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No user serviceable parts inside. Refer servicing to qualified
service personnel.
WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
The lightning flash with an arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of
uninsulated ‘dangerous voltage’
Arcam A49 Placing the unit
<
Place the amplifier on a level, firm surface, avoiding
direct sunlight and sources of heat or damp.
<
Do not place the A49/C49/P49/P349 on top of a
power amplifier or other source of heat.
<
Do not place the amplifier in an enclosed space
such as a bookcase or closed cabinet unless there is
good provision for ventilation. The A49/P49/P349
are designed to run warm during normal operation.
<
Do not place any other
Please read the ‘Placing the unit’, ‘Power’ and
‘Interconnect cables’ sections on page 5 before
connecting up your A49 integrated amplifier!
PHONO
GROUND
ONLY
PHONO
(MM)
CD
TUNER
SAT
BD
PVR
AV
RECORD
OUT
PRE
OUT
R
4–16 OHMS. CLASS 2 WIRING
SPEAKER 1
SPEAKER 2
L
4–16 OHMS. CLASS 2 WIRING
SPEAKER 2
SPEAKER 1
AUX R
AUX L
PRE OUT R
PRE OUT L
TRIGGER OUT
6V 1A12V 1.5A
ACCESSORY
POWER
110-120V/220-240
Please read the ‘Placing the unit’, ‘Power’ and ‘Interconnect cables’ sections on page 5 before
connecting up your P49 power amplifier!
ST/BRIDGE/DM
MODE
XLR/RCA
INPUT
25dB/31dB
GAIN
L
R
PRE
IN
PRE
OUT
R
4–16 OHMS. CLASS 2 WIRING
SPEAKER 1
SPEAKER 2
L
4–16 OHMS. CLASS 2 WIRING
SPEAKER 2
SPEAKER 1
PRE IN R
PRE IN L
110-120V/220-240V ~ 50-60 Hz
350W MAX
POWER INLET
SUPPLY
VOLTAGE
SWITCH POSITIONS
115 = 11
The POWER button switches the unit on and off.
The power light (next to the ‘POWER / STANDBY’
text) indicates the state of the amplifier: it changes from
red to orange then green if mains power is connected
and the unit is switched on.
If the unit is left unused for an extended period of time
it will go into standby to reduce power consumption.
Press AUX and BALANCE to adjust the time of this feature.
Display
The DISPLAY
SP1 and SP2
These buttons allow you to switch the speakers on and
off.
The LED above each button glows green to indicate
which speakers are currently selected. If you are using
the bi-wiring configuration described on page 15, both
SP1 and SP2 must be switched on.
Note that when both lights are out, the amplifier will
appear not to work, as all speakers are switched off.
SP1
SP2
POWER
POWER / STANDBY
Switching on
The POWER button switche
AMP Device Mode
The A Device Mode button configures the CR902 to
control your Arcam amplifier. Pressing this button does
not affect the currently selected input on the amplifier.
P
Toggles power between standby and on
DISP
Cycles through the front panel display’s
brightness options
MENU
Displays the amplifier setup menu on the
front panel
Navigate menus
O confirms a selection
@
Toggles the mute function of the amplifier
VOL-
VOL+
Decrea
Bi-amping requires the use of two amplifiers per
channel. Normally, your A49 is used to drive the high-
frequency (treble) speakers, while a power-amplifier
(such as a P49/P349) is used for the lower (bass)
frequencies.
Connect your A49 to the speakers as described for
single wiring, with the exception that the A49 should be
connected to the speaker terminals labelled HF or ‘High
Frequency’.
Then connect the power amplifier
4–16 OHMS. CLASS 2 WIRING
SPEAKER 1
SPEAKER 2
L
4–16 OHMS. CLASS 2 WIRING
SPEAKER 2
SPEAKER 1
PRE IN R
PRE IN L
110-120V/220-240V ~ 50-60 Hz
350W MAX
POWER INLET
SUPPLY
VOLTAGE
SWITCH POSITIONS
115 = 110 - 120V~
230 = 220 - 240V~
TRIGGER IN
TRIGGER OUT
LF
HF
PHONO
GROUND
ONLY
PHONO
(MM)
CD
TUNER
SAT
BD
PVR
AV
RECORD
OUT
PRE
OUT
AUX R
AUX L
PRE OUT R
PRE OUT L
TRIGGER
Continuous power output (20Hz—20kHz at 0.2% THD), per channel
Both channels, 8Ω, 20Hz—20kHz
200W
Single channel, 4Ω, at 1kHz
400W
Harmonic distortion, 80% power, 8Ω at 1kHz
0.001%
Inputs
Phono (MM) cartridge:
Input sensitivity at 1kHz
5mV
Input impedance
47kΩ + 100pF
Frequency response (ref. RIAA curve)
20Hz—20kHz ± 1dB
Signal/noise ratio (Awtd) 50W, ref. 5mV input
80dB
Overload margin, 5mV at 1kHz
20dB
Inputs:
RCA type
XLR typ
Continuous power output (20Hz—20kHz at 0.2% THD), per channel Both channels, 8Ω, 20Hz—20kHz
200W
Single channel, 4Ω, at 1kHz
400W
Harmonic distortion, 80% power, 8Ω at 1kHz
0.001%
Inputs
PWR IN input:
RCA type
XLR type
Nominal sensitivity for 200W / 8Ω
1.15V
2.3V
Input impedance
10kΩ
10kΩ
Frequency response
20Hz—20kHz ± 0.05dB
Signal/noise ratio (Awtd) ref 50W / 8Ω
110dB
General
Mains voltage
110–120V~ or 220–240V~
Power
Correct disposal of this product
This marking indicates that this
product should not be disposed
with other household waste
throughout the EU.
To prevent possible harm to the
environment or human health from
uncontrolled waste disposal and to
conserve material resources, this product should be
recycled responsibly.
To dispose of your product, please use your local
return and collection systems or contact the retailer
where the produc