Balluff Network Interface / IO-Link BNI IOL-302-002-E012

www.balluff.com 2 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions 4 Enumerations 4 Actions 4 Syntax 4 Cross-references 4 1.3. Symbols 4 1.4. Abbreviations 4 1.5. Deviating views 4 2 Safety 5 2.1. Intended use 5 2.2. Installation and Startup 5 2.3. General Safety ...

Setting the serial number 54hex

22 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves 23 7.1. IO-Link data 23 7.2. Process Data/Input Data 23 7.3. Process Data/ Output Data 24 7.4. Parameter Data / Demand Data 25 Inversion of the inputs 40hex 26 Configuration of inputs/outputs 41hex 26 Safe state of Outputs 42hex 27 Sa ...

Balluff Network Interface / IO-Link BNI IOL-302-002-E012

www.balluff.com 4 1 General 1.1. Structure of the Manual The manual is organized so that the sections build on one another. Chapter 2: Basic Safety Information. …….. 1.2. Typographical Conventions The following typographical conventions are used in this manual. Enumerations Enumerations are ...

2.1. Intended use

The BNI IOL-… acts as a decentralized input/output sensor module, which is connected to a higher-level IO-Link master module through an IO-Link interface. 2.2. Installation and Startup Attention! Installation and startup must only be carried out by trained technical personnel. Qualified personnel are people wh ...

Balluff Network Interface / IO-Link BNI IOL-302-002-E012

www.balluff.com 6 3 First Steps 3.1. Connection Overview Figure 3-1: Connection overview BNI IOL-302-002-E012 1 Mounting hole/ground 2 Status LED: communication 3 Port 1 4 Port 3 5 Port 5 6 Port 7, extension port 7 Pin/Port LED: signal status 8 Port 6 9 Port 4 10 Port 2 11 Port 0 12 Status LED: s ...

The BNI IOL modules are attached using 2 M6 screws and 2 washers.

3.3. Electrical Connection The modules do not require a separate supply voltage connection. Supply voltage is provided via the IO-Link interface and the higher-level IO-Link master module. Function ground Fig. 3-3: Ground connection ...

Balluff Network Interface / IO-Link BNI IOL-302-002-E012

www.balluff.com 8 3 First Steps Connecting the sensor hub  Connect ground conductor to the functional ground connection, if available.  Connect the incoming IO-Link cable to the sensor hub. Note A standardized sensor cable is used to connect to the higher-level to the IO-Link master module. ...

The modules gives you the ability to use the No. 7 slot in various ways. By default, it is used

as a digital input slot, where both pin 2 and pin 4 can be used as a digital input. This slot can be used as an extension port by making a corresponding entry in the parameter with an index of 55hex. This makes it possibl ...

Balluff Network Interface / IO-Link BNI IOL-302-002-E012

www.balluff.com 10 5 Configuration: "Extension Off" 5.1. IO-Link data BNI IOL-302-002-E012 extension off Transmission rate COM2 (38.4 kBaud) Minimum cycle time 4.0 ms Process data length 2 byte input, 2 byte output 5.2. Process Data/Input Data Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Descripti ...