Balluff BNI IOL-302-002-E012 Operation & User’s Manual
File Specifications
| Brand: | Balluff |
| Category: | Switch |
| Model: | BNI IOL-302-002-E012 (Operation & User’s Manual), prbXTNUN3EE5s |
| File Type: | |
| File Size: | — |
| Pages: | 38 pages |
Download PDF
Download Balluff BNI IOL-302-002-E012 Manual (38 pages)Read Online:
Read the Balluff BNI IOL-302-002-E012 Operation & User’s Manual online using the built-in PDF viewer.
Key Pages of Document
www.balluff.com 2 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions 4 Enumerations 4 Actions 4 Syntax 4 Cross-references 4 1.3. Symbols 4 1.4. Abbreviations 4 1.5. Deviating views 4 2 Safety 5 2.1. Intended use 5 2.2. Installation and Startup 5 2.3. General Safety ...
22 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves 23 7.1. IO-Link data 23 7.2. Process Data/Input Data 23 7.3. Process Data/ Output Data 24 7.4. Parameter Data / Demand Data 25 Inversion of the inputs 40hex 26 Configuration of inputs/outputs 41hex 26 Safe state of Outputs 42hex 27 Sa ...
www.balluff.com 4 1 General 1.1. Structure of the Manual The manual is organized so that the sections build on one another. Chapter 2: Basic Safety Information. …….. 1.2. Typographical Conventions The following typographical conventions are used in this manual. Enumerations Enumerations are ...
The BNI IOL-… acts as a decentralized input/output sensor module, which is connected to a higher-level IO-Link master module through an IO-Link interface. 2.2. Installation and Startup Attention! Installation and startup must only be carried out by trained technical personnel. Qualified personnel are people wh ...
www.balluff.com 6 3 First Steps 3.1. Connection Overview Figure 3-1: Connection overview BNI IOL-302-002-E012 1 Mounting hole/ground 2 Status LED: communication 3 Port 1 4 Port 3 5 Port 5 6 Port 7, extension port 7 Pin/Port LED: signal status 8 Port 6 9 Port 4 10 Port 2 11 Port 0 12 Status LED: s ...
3.3. Electrical Connection The modules do not require a separate supply voltage connection. Supply voltage is provided via the IO-Link interface and the higher-level IO-Link master module. Function ground Fig. 3-3: Ground connection ...
www.balluff.com 8 3 First Steps Connecting the sensor hub Connect ground conductor to the functional ground connection, if available. Connect the incoming IO-Link cable to the sensor hub. Note A standardized sensor cable is used to connect to the higher-level to the IO-Link master module. ...
as a digital input slot, where both pin 2 and pin 4 can be used as a digital input. This slot can be used as an extension port by making a corresponding entry in the parameter with an index of 55hex. This makes it possibl ...
www.balluff.com 10 5 Configuration: "Extension Off" 5.1. IO-Link data BNI IOL-302-002-E012 extension off Transmission rate COM2 (38.4 kBaud) Minimum cycle time 4.0 ms Process data length 2 byte input, 2 byte output 5.2. Process Data/Input Data Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Descripti ...
⚠️ Download Safety
The Switch Operation & user’s manual (38 pages) is completely safe to download (last scan date: 27/03/2026).
Related PDF Instructions for Balluff BNI IOL-302-002-E012:
-
Balluff BTL6-V5 V-M PF-S115 Series Transducer Operation & user’s manual, 80 pages
-
Balluff Subnet16 BIS Z-GW-001-PBS Gateway Installation manual, 2 pages
-
Balluff BES M30MH2-GNX15F-BT02-EXB Kitchen Appliances Operation & user’s manual, 32 pages
-
Balluff BTL7-C/E508-M Series Transducer Operation & user’s manual, 115 pages
-
Balluff BNI EIP-502-105-Z015 Control Unit Operation & user’s manual, 20 pages
-
Balluff BIS M-4A9-082-401-07-PU1-0,3 Cables and connectors Assembly instructions manual, 12 pages