Digital Light Meter
Additional User Manual Translations available at www.extech.com
Congratulations on your purchase of the Extech Digital Light Meter. This device is shipped fully tested
and calibrated and, with proper use, will provide years of reliable service. Please visit our website
(www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer
Support.
Meter Description
1.
LCD Display
2.
Data Hold Switch
3.
Power Off/Range Switch
4.
Analog Output Terminal
5
Extech Instruments 401025 1. Select Units (Lux or Ft-candle) and the Response Time (Fast/Slow) using the slide switch. Typical
selection is Slow and Fc using the gray lettering.
2. Select the maximum range using the Range Switch.
3. Hold the Light Sensor so that the senso
Selecting a Measurement Range
The meter has three measurement ranges for each unit of measure (0-200, 0-2000, and 0-5000 Fc)
and (0-2000, 0-20000, and 0-50000) Lux). The proper range selection will produce the most accurate
reading. Always select the range that produces the maximum number of digits without exceeding the
maximum count for that particular range. For example, a reading of 1456 Fc should be read on the 0
- 2000 range
Extech Instruments 401025 Replacing the Battery
When the left corner of the LCD display shows LO BAT the battery output is below the design limit and
the battery needs to be replaced. However, reliable measurement can still be taken for several hours
before the tester becomes inaccurate or switches off.
1. Open the Battery Cover at the back of the tester and remove the old battery.
2. Replace with a new 9V battery and install the cover securely.
Never dis
± (5% + 2digits)
20,000 Lux
2,000-19,990 Lux
10 Lux
± (5 % + 2digits)
50,000 Lux
20,000-50,000 Lux
100 Lux
±- (5 % + 2digits)
Foot-candle (Fc)
Range
In-range Display
Resolution
Accuracy (FS)
200 Fc
0-199.9 Fc
0.1 Fc
± (5% + 2digits)
2,000 Fc
200-1,999 Fc
1 Fc
± (5% + 2digits)
5,000 Fc
2,000-5,000 Fc
10 Fc
± (5% + 2digits)
Fr
Extech Instruments 401025 Appendix A - Typical Light Levels
Lux
Foot
Candles
Lux
Foot
Candles
Factories
Home
20-75
2-7
Emergency Stairs,
Warehouse
100-150
10-15
Washing
75-150
7-15
Exit/Entrance Passages
150-200
15-20
Recreational
Activities
150-300
15-30
Packing Work
200-300
20-30
Drawing Room,
Table
300-750
30-75
Visual Work: Production
Line
300-500
30-50
Makeup
750-1,500 75-150
Typesetting: Inspection
Work
500-1,500
50-150
Reading, Study
1,500-
3
Extech Instruments Measuring Instruments Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
SDL100 |
#6V55J5: SDL100 Measuring Instruments Operation & user’s manual |
11 | 890 | 170 | 02-09-2026 | |
407750 |
Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 01-07-2026) |
7 | 1299 | 221 | 01-07-2026 | |
EMF510 |
#572OB7: EMF510 Measuring Instruments Operation & user’s manual |
6 | 580 | 116 | 15-09-2026 | |
475040 |
#5X276N: 475040 Measuring Instruments Operation & user’s manual |
6 | 269 | 52 | 16-08-2026 | |
407445 |
#1WDZH3: 407445 Measuring Instruments Instruction manual |
4 | 511 | 82 | 08-06-2026 | |
407112 |
407112 Operation & user’s manual - 824PFT |
8 | 767 | 146 | 04-07-2026 | |
451126 |
Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 01-07-2026) |
16 | 0.28 Mb | 215 | 50 | 01-07-2026 |
EC210 |
Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 06-05-2026) |
8 | 74 | 13 | 06-05-2026 | |
RH300 |
#XYVX12: RH300 Measuring Instruments Operation & user’s manual |
8 | 1095 | 176 | 10-05-2026 |