Keysight E5071C Configuration Manual
Text of the manual
E5071C Network Analyzer
– 9 kHz to 4.5/6.5/8.5 GHz
– 100 kHz to 4.5/6.5/8.5 GHz (with bias tees)
– 300 kHz to 14/20 GHz (with bias tees)
E5092A Configurable Multiport Test Set
Configuration Guide
02 | Keysight | E5071C Network Analyzer - Configuration Guide
1. Order the 82357B USB/GPIB interface at the same time if you want to
control power meters with the E5071C. This will allow you to conduct
scalar mixer calibrations (SMC), power calibrations, or receiver calibra-
tions after power calibrations.
2. E5071C-TDR is a superset of E5071C-010. To add option TDR, you do not
need to have option 010 already installed; however, you can have both
option 010 and TDR installed in one instrument
3. Consider purchasing Keysight 20mm TORQUE WRENCH 8710-1764 for
NMD 3.5 mm(f) test port connector.
This configuration guide describes standard configurations, op-
tions, accessories and peripherals for the E5071C ENA network
analyzer. Refer to the ENA brochure for a complete description of
the ENA network analyzer and the E5092A configurable multiport
test set.
E5071C ENA Network Analyzer
The ENA is an integrated network analyzer with a two- or four-
port S-parameter test set, a synthesized RF source, a 10.4-inch
color LCD, and a hard disk drive. A 3-year return-to-Keysight
Technologies, Inc. service warranty is included with the each ENA
network analyzer.
Step 1: Select frequency range, number of test
ports, and with or without bias tees
Up to 4.5 GHz range
9 kHz to 4.5 GHz (without bias tees)
E5071C-240
2-port S-parameter test set
E5071C-440
4-port S-parameter test set
100 kHz to 4.5 GHz (with bias tees)
E5071C-245
2-port S-parameter test set
E5071C-445 4-port S-parameter test set
Up to 6.5 GHz range
9 kHz to 6.5 GHz (without bias tees)
E5071C-260
2-port S-parameter test set
E5071C-460
4-port S-parameter test set
100 kHz to 6.5 GHz (with bias tees)
E5071C-265
2-port S-parameter test set
E5071C-465
4-port S-parameter test set
Up to 8.5 GHz range
9 kHz to 8.5 GHz (without bias tees)
E5071C-280
2-port S-parameter test set
E5071C-480
4-port S-parameter test set
100 kHz to 8.5 GHz (with bias tees)
E5071C-285
2-port S-parameter test set
E5071C-485
4-port S-parameter test set
Up to 14 GHz range3
300 kHz to 14 GHz (with bias tees)
E5071C-2D5 2-port S-parameter test set
E5071C-4D5 4-port S-parameter test set
Up to 20 GHz range3
300 kHz to 20 GHz (with bias tees)
E5071C-2K5
2-port S-parameter test set
E5071C-4K5
4-port S-parameter test set
Step 2: Select time base
E5071C-1E5
High stability time base
E5071C-UNQ
Standard stability time base
Step 3: Select hard disk drive
E5071C-017
Removable hard disk drive
E5071C-019
Standard hard disk drive
Step 4: Choose additional options (Optional)
E5071C-0081
Frequency offset mode
E5071C-TDR2 Enhanced time domain analysis
E5071C-010
Time domain analysis
E5071C-790
Measurement Wizard Assistant software
Step 5: Choose accessories (Optional)
E5071C-1CM
Rack mount kit,
E5071C-1CN
Front handle kit
E5071C-1CP
Rack mount and front handle kit
E5071C-810
Adds a keyboard
E5071C-820
Adds a mouse
Step 6: Choose certification documentation
(Optional)
E5071C-1A7
ISO 17025 compliant calibration
E5071C-A6J
ANSI Z540 compliant calibration
Step 7: Choose your warranty service
(Optional)
5 year return-to Keysight warranty and service
Documentation
The documentation for the E5071C is located in the
Online Help system for the E5071C ENA network analyzer.
The ENA Service Guide and Online Help system are also available
on the Web site:
www.keysight.com/find/ena
Additional product information
For additional product information, refer to the ENA
brochure available on the Web site:
www.keysight.com/find/ena
03 | Keysight | E5071C Network Analyzer - Configuration Guide
Receiver assignment
Port 1
R1 A
R2 B
R3 C
R4 D
Port 2
Port 3
Port 4
Port 1
R1 A
R2 B
Port 2
2-port test set option
4-port test set option
04 | Keysight | E5071C Network Analyzer - Configuration Guide
E5071C ENA Network Analyzer
Options
To add options to a product, order the corresponding item number.
Option1
Description
Additional information
Test set
Option 240
Option 440
Option 245
Option 445
Option 260
Option 460
Option 265
Option 465
Option 280
Option 480
Option 285
Option 485
2-port test set, 9 kHz to 4.5 GHz without bias tees
4-port test set, 9 kHz to 4.5 GHz without bias tees
2-port test set, 100 kHz to 4.5 GHz with bias tees
4-port test set, 100 kHz to 4.5 GHz with bias tees
2-port test set, 9 kHz to 6.5 GHz without bias tees
4-port test set, 9 kHz to 6.5 GHz without bias tees
2-port test set, 100 kHz to 6.5 GHz with bias tees
4-port test set, 100 kHz to 6.5 GHz with bias tees
2-port test set, 9 kHz to 8.5 GHz without bias tees
4-port test set, 9 kHz to 8.5 GHz without bias tees
2-port test set, 100 kHz to 8.5 GHz with bias tees
4-port test set, 100 kHz to 8.5 GHz with bias tees
Test port connector: Type-N (f)
Option 2D5
Option 4D5
Option 2K5
Option 4K5
2-port test set, 300 kHz to 14 GHz with bias tees
4-port test set, 300 kHz to 14 GHz with bias tees
2-port test set, 300 kHz to 20 GHz with bias tees
4-port test set, 300 kHz to 20 GHz with bias tees
Test port connector: 3.5 mm (m)5
Time base
Option UNQ
Option 1E5
Standard stability time base
High stability time base
Adds a higher stability time base reference.
Hard disk drive
Option 017
Option 019
Removable hard disk drive
Standard hard disk drive
Additional features
Option 0082
Option TDR3
Option 010
Option 7904
Frequency offset mode
Enhanced time domain analysis
Time domain analysis
Measurement wizard assistant software
Adds frequency-offset sweep and harmonic measurement capabilities.
Adds time domain transform, gating capabilities and graphical user
interface to simplify time domain measurements.
Adds time domain transform and gating capabilities.
Adds Measurement Wizard Assistant (MWA) software to simplify your
multiport measurements with the 4-port ENA
Accessories
Option 1CM
Option 1CN
Option 1CP
Option 810
Option 820
Rack mount kit
Front handle kit
Rack mount and front handle kit
Add keyboard
Add mouse
Adds a rack mount kit (part number: 1CM015A) for use without
handles.
Adds a front handle kit (part number: 1CN005A).
Adds a rack mount and front handle kit (part number: 1CN009A).
Calibration documentation
Option 1A7
Option A6J
ISO 17025 compliant calibration
ANSI Z540 compliant calibration
1. Options are ordered using the combined model/option number, e.g. E5071C-240.
2. Order the 82357B USB/GPIB interface at the same time if you want to control power meters with the E5071C. This will allow you to conduct scalar mixer
calibrations (SMC), power calibrations, or receiver calibrations after power calibrations.
3. Option TDR is a superset of Option 010. Option TDR and Option 010 are mutually exclusive options and there is no need to purchase both options.
4. When using an ECal module with the MWA calibration wizard, a 4-port ECal module (i.e. N4431B, N4433A) is required.
5. Consider purchasing Keysight 20mm TORQUE WRENCH 8710-1764
05 | Keysight | E5071C Network Analyzer - Configuration Guide
SW6 6A 6B
6COM
SW7 7A 7B
7COM
SW8 8A 8B
8COM
SW9 9A 9B
9COM
SW10 10A10B
10COM
SW5 5A
5COM
5B
SW1
1A 1B 1C 1D
PORT 1
SW2
2A 2B 2C 2D
PORT 2
SW3
3A 3B 3C 3D
PORT 3
SW4
4A 4B 4C 4D
PORT 4
1. Semi-rigid cables are designed for connection to the E5071C and are not available for the E5070B, E5071B.
E5092A Configurable Multiport Test Set
This guide is intended to assist you in the ordering process of the
E5092A configurable multiport test set for use with the 4-port
ENA (E5070B, E5071B and E5071C). Multiple multiport measure-
ment configurations, from 50 MHz to 20 GHz, can be made by
connecting included semi-rigid cables to the E5092A's front panel
which accesses its internal switches.
Step 1:1 Select appropriate cable and adapter set
for connection to the ENA (Optional)
E5092A-08C
Cables and adapters for connection to
E5071C Option 440/445/460/465/480/485
E5092A-20C
Cables and adapters for connection to
E5071C Option 4D5/4K5
Step 2: Choose accessories (Optional)
E5092A-1CM
Rack mount kit only
E5092A-1CN
Front handle kit only
E5092A-1CP
Rack mount kit with handle kit
Step 3: Choose calibration certification
documentation (Optional)
E5092A-1A7
ISO 17025 compliant calibration
E5092A-A6J
ANSI Z540 compliant calibration
Step 4: Choose your warranty service
(Optional)
3 year return-to-Keysight warranty and service
5 year return-to-Keysight warranty and service
Block diagram
E5092A (Option 020)
Documentation
The documentation for the E5092A is located in the
Online Help system for the E5071C ENA network analyzer. The
ENA Service Guide and Online Help system are also available on
the Web site:
www.keysight.com/find/ena
Additional product information
For additional product information, refer to the ENA
brochure available on the Web site:
www.keysight.com/find/ena
www.keysight.com/find/multiport
06 | Keysight | E5071C Network Analyzer - Configuration Guide
E5092A Configurable Multiport Test Set
Options
To add options to a product, order the corresponding option number.
Option1
Description
Additional information
Test set
Option 020
20 GHz switching test set
Up to 22-port or 10-port full crossbar
measurement.
Cable adapter set
Option 08C
Cable and adapter set for
E5071C Option 440/445/460/465/480/485
(4.5 GHz/6.5 GHz/8.5 GHz)
Adds SMA semi-rigid cables and type-N-to-SMA adapters for
connection to the E5071C.
Option 20C
Cable and adapter set for the E5071C
Option 4D5/4K5 (14 GHz/20 GHz)
Adds SMA semi-rigid cables and 3.5 mm-to-3.5 mm adapters for
connection to the E5071C.
Accessories
Option 1CM
Rack mount kit
Adds a rack mount kit (part number: 1CM015A) for use without
handles.
Option 1CN
Front handle kit
Adds a front handle kit (part number: 1CN007A).
Option 1CP
Rack mount and front handle kit
Adds a rack mount and front handle kit (part
number: 1CP008A).
Calibration documentation
Option 1A7
ISO 17025 compliant calibration
Option A6J
ANSI Z540 compliant calibration
1. Options are ordered using the combined model/option number, e.g. E5092A-020.
07 | Keysight | E5071C Network Analyzer - Configuration Guide
Option 1E5 High stability time base
Option 1E5 provides the following stability:
CW accuracy:
±1 ppm (specification)
Source stability: ±0.05 ppm (5 °C to 40 °C typical),
± 0.5 ppm/year
Hard disk drive options2
Option 019 Standard hard disk drive
Option 019 provides a fixed hard disk drive. The removable disk
drive is not available.
Option 017 Removable hard disk drive
Option 017 provides a removable hard disk drive. You can remove
or replace the hard disk drive for secure area operations. If a
spare disk is needed, order E5071CU-058 Solid state drive kit.
Certification options
Option 1A7 ISO 17025 compliant calibration
Option 1A7 provides a complete set of measurements which test
the unit to manufacturer’s published specifications. Includes cali-
bration label, ISO 17025 calibration certificate, and data report,
and measurement uncertainties and guardbands on all customer
specifications. Conforms to ISO 17025 and ISO 9001.
Option A6J ANSI Z540 compliant calibration
Option A6J provides a complete set of measurements which test
the unit to manufacturer’s published specifications. Includes
pre- and post-adjustment data and measurement uncertainty
information compliant with the ANSI/NCSL Z540 standard.
1. When using an ECal module with MWA calibration wizard, a 4-port ECal
module (i.e. N4431B, N4433A) is required.
2. A solid state drive is used as storage from Sep 2012.
ENA Network Analyzer (E5071C)
Additional software options
Option TDR Enhanced time domain analysis
Option TDR enables the ENA to view reflection and transmission
responses in the time domain using a simple and intuitive graphi-
cal user interface. Use time domain to tune filters, gate out the
response of fixtures and cables, characterize the impedance of
transmission lines, and more.
Option 010 Time domain analysis
Option 010 enables the ENA to view reflection and transmission
responses in the time domain. Use time domain to tune filters,
gate out the response of fixtures and cables, characterize the
impedance of transmission lines, and more.
Option 008 Frequency offset mode
Option 008 enables the ENA to set the receiver frequencies
independently from where the source frequency is tuned. This
ability is important for harmonic distortion measurements and
for measuring frequency converting devices such as mixers and
converters. Advanced calibration techniques for the ENA, such as
scalar mixer calibration (SMC) or vector mixer calibration (VMC),
require this option.
Option 790 Measurement Wizard Assistant
Option 790 provides a simple measurement procedure setup for
the 4-port ENA with a multiport test set such as the E5092A. The
software delivers an easy-to-use measurement wizard programs
including a calibration wizard setup1, which reduces operation
time for complicated, time-consuming multiport measurements.
Time base options
Option UNQ Standard stability time base
Option UNQ provides following stability:
CW accuracy:
±5 ppm (specification)
Source stability: ±5 ppm (5 °C to 40 °C typical)
08 | Keysight | E5071C Network Analyzer - Configuration Guide
1. A sliding load is not supported by the ENA.
2. An offset load is not supported by the ENA.
Measurement Accessories
A complete list of RF and microwave test accessories
is available on our Web site: www.keysight.com/find/accessories
Accessories are available with the following connector types:
50 Ω Type-N, 3.5 mm, 7 mm, 2.4 mm, 2.92 mm, 1.85 mm, 1.0 mm
and waveguide.
Test port cables and a calibration kit/ECal module should be
added for a complete measurement system.
Calibration kits
Coaxial measurements
Mechanical calibration kits include standards, such as opens,
shorts and loads, which are measured by the network analyzer for
increased measurement accuracy.
Electronic calibration (ECal) kits replace mechanical calibration
standards with one solid-state calibration module that is con-
trolled by the network analyzer via USB. ECal kits provide many
different impedances to the test ports which enables a full two-
port calibration to be performed quickly with a single connection.
This technique reduces operator errors and connector wear and
abrasion.
Choose a calibration kit for each connector type to be used.
Economy, includes:
– open standards (male and female)
– short standards (male and female)
– fixed-termination standards (male and female)
Standard, includes the devices in the economy kit and adds:
– sliding load standards1 (male and female) or a series of offset
shorts
Precision, includes the devices in the economy kit and adds:
– 50 Ω airline(s) for TRL calibration
– TRL adapters
Waveguide measurements
For waveguide measurements, Keysight offers mechanical cali-
bration kits that include:
– waveguide-to-coax adapters (X, P, K, R, Q, U, and V bands)
– precision waveguide section
– flush short circuit
– fixed terminations2
– straight section
Cables and adapter sets
Keysight offers the following types of cables:
– single cables: semi-rigid or flexible
– cable sets: semi-rigid or flexible
There are also adapter sets that protect the test port
and convert the port to the desired connector interface. These
kits contain:
– one male adapter
– one female adapter
To attain the best mechanical rigidity for device connection, use a
single cable and the appropriate special adapter set. To attain the
greatest flexibility for device connection, use a cable set.
09 | Keysight | E5071C Network Analyzer - Configuration Guide
For devices with 50 Ω Type-N
connectors
Mechanical calibration kits
– 85032F economy: DC to 9 GHz. Includes:
85032-60017 Type-N (m) fixed load
85032-60018 Type-N (f) fixed load
85032-60013 Type-N (m) open
85032-60014 Type-N (f) open
85032-60016 Type-N (m) short
85032-60015 Type-N (f) short
– Option 85032F-100 adds:
85032-60021 Type-N (f) to Type-N (f) adapter
– Option 85032F-200 adds:
85032-60019 Type-N (m) to Type-N (m) adapter
– Option 85032F-300 adds:
85032-60020 Type-N (m) to Type-N (f) adapter
– Option 85032F-500 adds:
85054-60001 Type-N (f) to 7 mm adapter (two included)
85054-60009 Type-N (m) to 7 mm adapter (two included)
– 85054D economy: DC to 18 GHz. Includes:
85054-60025 Type-N (m) short
85054-60026 Type-N (f) short
85054-60027 Type-N (m) open
85054-60028 Type-N (f) open
85054-60031 Type-N (f) to 7 mm adapter
85054-60032 Type-N (m) to 7 mm adapter
85054-60037 Type-N (f) to Type-N (f) adapter
85054-60038 Type-N (m) to Type-N (m) adapter
85054-60046 Type-N (m) fixed load
85054-60047 Type-N (f) fixed load
Electronic calibration kits
– 85092C RF ECal: 300 kHz to 9 GHz, 2 ports
Includes:
Option 85092C-MOF module with:
85092-60008 Type-N (f) to Type-N (m) RF ECal module
Option Option 85092C-00M module with:
85092-60009 Type-N (m) to Type-N (m) RF ECal module
Option 85092C-00F module with:
85092-60010 Type-N (f) to Type-N (f) RF ECal module
Option 85092C-00A adds:
85054-60037 Type-N (f) to Type-N (f) adapter
85054-60038 Type-N (m) to Type-N (m) adapter
– N4431B Microwave ECal: 9 kHz to 13.5 GHz, 4 ports1
Includes:
Option 020 module with:
N4431-60007 4 x Type-N (f) ECal module
N4431B-xxx mixed-connector options:
Connector type
Port A
option
Port B
option
Port C
option
Port D
option
3.5 mm (f)
101
201
301
401
3.5 mm (m)
102
202
302
402
Type-N 50 Ω (f)
103
203
303
403
Type-N 50 Ω (m)
104
204
304
404
7-16 (f)
105
205
305
405
7-16 (m)
106
206
306
406
1. Performance from 9 kHz to 300 kHz is valid only for the E5071C ENA
network analyzer with firmware version A.09.10 or higher.
10 | Keysight | E5071C Network Analyzer - Configuration Guide
– N4432A Microwave ECal: 300 kHz to 18 GHz, 4 ports
Includes:
Option 020 module with:
N4432-60003 4 x Type-N (f) ECal module
N4432A-xxx mixed-connector options:
Connector type
Port A
option
Port B
option
Port C
option
Port D
option
3.5 mm (f)
101
201
301
401
3.5 mm (m)
102
202
302
402
Type-N 50 Ω (f)
103
203
303
403
Type-N 50 Ω (m)
104
204
304
404
– N4690B Microwave ECal: 300 kHz to 18 GHz, 2 ports
Includes:
Option M0F module with:
N4690-60001 Type-N (f) to Type-N (m) ECal module
Option 00M module with:
N4690-60002 Type-N (m) to Type-N (m) ECal module
Option 00F module with:
N4690-60003 Type-N (f) to Type-N (f) ECal module
Option 00A adds:
85054-60037 Type-N (f) to Type-N (f) adapter
85054-60038 Type-N (m) to Type-N (m) adapter
Cables
– N6314A 50 Ω Type-N RF cable, DC to 12.4 GHz
Includes 8120-8862 one 610 mm (24 in) cable with male con-
nectors
– N6315A 50 Ω Type-N RF cable, DC to 12.4 GHz
Includes 8121-0027 one 610 mm (24 in) cable with both
female and male connectors
Adapters
– 11853A 50 Ω Type-N accessory kit. Includes:
1250-1472 Type-N (f) to Type-N (f) adapter (two included)
1250-1475 Type-N (m) to Type-N (m) adapter (two included)
11511A Type-N (f) short
11512A Type-N (m) short
– 11878A Type-N to 3.5 mm adapter kit. Includes:
1250-1744 3.5 mm (f) to 50 Ω Type-N (m) adapter
1250-1743 3.5 mm (m) to 50 Ω Type-N (m) adapter
1250-1745 3.5 mm (f) to 50 Ω Type-N (f) adapter
1250-1750 3.5 mm (m) to 50 Ω Type-N (f) adapter
– 11524A 7 mm to Type-N (f) adapter
– 11525A 7 mm to Type-N (m) adapter
– 85130C1,2,3 3.5 mm to Type-N Includes:
85054-60029 NMD-3.5 mm to Type-N (f)
85054-60030 NMD-3.5 mm to Type-N (m)
1. Special rugged female connector specifically for connecting to the net-
work analyzer test port, but does not mate with a standard
male connector.
2. Recommended to connect H device to E5071C option xD5/xK5 which has
NMD-3.5 mm (m) connectors.
3. Consider purchasing Keysight 20mm TORQUE WRENCH 8710-1764
11 | Keysight | E5071C Network Analyzer - Configuration Guide
For devices with 3.5 mm or SMA connectors
Mechanical calibration kits
– 85033E economy: DC to 9 GHz. Includes:
85033-60016 3.5 mm (m) load
85033-60017 3.5 mm (f) load
85033-60018 3.5 mm (m) open
85033-60019 3.5 mm (f) open
85033-60020 3.5 mm (m) short
85033-60021 3.5 mm (f) short
8710-1761 torque wrench
Option 85033E-100 adds:
85027-60005 3.5 mm (f) to 3.5 mm (f) adapter
Option 85033E-200 adds:
85027-60007 3.5 mm (m) to 3.5 mm (m) adapter
Option 85033E-300 adds:
85027-60006 3.5 mm (m) to 3.5 mm (f) adapter
Option 85033E-400 adds:
1250-1744 3.5 mm (f) to 50 Ω Type-N (m) adapter
1250-1743 3.5 mm (m) to 50 Ω Type-N (m) adapter
1250-1745 3.5 mm (f) to 50 Ω Type-N (f) adapter
1250-1750 3.5 mm (m) to 50 Ω Type-N (f) adapter
Option 85033E-500 adds:
1250-1746 3.5 mm (m) to 7 mm adapter (two included)
1250-1747 3.5 mm (f) to 7 mm adapter (two included)
– 85052C precision TRL: DC to 26.5 GHz. Includes:
00902-60003 3.5 mm (m) fixed load
00902-60004 3.5 mm (f) fixed load
85052-60006 3.5 mm (m) short
85052-60007 3.5 mm (f) short
85052-60008 3.5 mm (m) open
85052-60009 3.5 mm (f) open
85052-60032 3.5 mm (f) to 3.5 mm (f) adapter
85052-60033 3.5 mm (m) to 3.5 mm (m) adapter
85052-60034 3.5 mm (f) to 3.5 mm (m) adapter
85052-60035 3.5 mm short TRL line
85052-60036 3.5 mm long TRL line
– 85052D economy: DC to 26.5 GHz. Includes:
00902-60003 3.5 mm (m) fixed load
00902-60004 3.5 mm (f) fixed load
85052-60006 3.5 mm (m) short
85052-60007 3.5 mm (f) short
85052-60008 3.5 mm (m) open
85052-60009 3.5 mm (f) open
85052-60012 3.5 mm (f) to 3.5 mm (f) adapter
85052-60013 3.5 mm (f) to 3.5 mm (m) adapter
85052-60014 3.5 mm (m) to 3.5 mm (m) adapter
Electronic calibration kits
– 85093C RF ECal: 300 kHz to 9 GHz, 2 ports
Standard module includes:
Option M0F with:
85093-60008 3.5 mm (f) to 3.5 mm (m) ECal module
Option 00F module with:
85093-60010 3.5 mm (f) to 3.5 mm (f) ECal module
Option 00M module with:
85093-60009 3.5 mm (m) to 3.5 mm (m) ECal module
Option 00A adds:
85052-60012 3.5 mm (f) to 3.5 mm (f) adapter
85052-60014 3.5 mm (m) to 3.5 mm (m) adapter
85093C-xxx mixed-connector options:
Port A option
Port B option
Type
(f)
(m)
Type
(f)
(m)
Type
(f)
(m)
3.5 mm
101
102
Type-N
203
204
7-16
205
206
– N4431B Microwave ECal: 9 kHz to 13.5 GHz, 4 ports1
Includes:
Option 010 module with:
N4431-60006 4 x 3.5 mm (f) ECal module
N4431B-xxx mixed-connector options:
Connector
type
Port A
option
Port B
option
Port C
option
Port D
option
3.5 mm
201
301
401
3.5 mm (m)
102
202
302
402
Type-N
50 Ω (f)
103
203
303
403
Type-N
50 Ω (m)
104
204
304
404
7-16 (f)
105
205
305
405
7-16 (m)
106
206
306
406
– N4433A Microwave ECal: 300 kHz to 20 GHz, 4 ports
Includes:
Option 010 module with:
N4433-60003 4 x 3.5 mm (f) ECal module
1. Performance from 9 kHz to 300 kHz is valid only for the E5071C ENA
network analyzer with firmware version A.09.10 or higher.
12 | Keysight | E5071C Network Analyzer - Configuration Guide
1. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard male con-
nector.
2. 1250-1744 3.5 mm (f) to 50 Ω Type-N (m) adapters are recommended to
connect to the E5071C Option x4x, x6x, and x8x test ports, which have
Type-N (f) connectors.
3. NMD-3.5 mm (f) to 3.5 mm (f), or 3.5 mm (f) to 3.5 mm (f) adapters are
recommended to connect to the E5071C Option xD5, xK5, which have
NMD-3.5 mm (m) connectors.
4. Consider purchasing Keysight 20mm TORQUE WRENCH 8710-1764
N4433A-xxx mixed-connector options:
Connector
type
Port A
option
Port B
option
Port C
option
Port D
option
3.5 mm (f)
101
201
301
401
3.5 mm (m)
102
202
302
402
– N4691B Microwave ECal: 300 kHz to 26.5 GHz, 2 ports.
Includes:
Option M0F module with:
N4691-60001 3.5 mm (f) to 3.5 mm (m) ECal module
Option 00M module with:
N4691-60002 3.5 mm (m) to 3.5 mm (m) ECal module
Option 00F module with:
N4691-60003 3.5 mm (f) to 3.5 mm (f) ECal module
Option 00A adds:
85052-60012 3.5 mm (f) to 3.5 mm (f) adapter
85052-60014 3.5 mm (m) to 3.5 mm (m) adapter
Cables
– 11500E2, 3, 4 cable, APC 3.5 mm (m), DC to 26.5 GHz
Includes: one 610 mm (24 in) with male connectors.
– 11500F2, 3, 4 150 cm cable, APC 3.5 mm (m), DC to 26.5 GHz
Includes: one 1520 mm (60 in) with male connectors.
– 85131C1, 4 single, semi-rigid:
3.5 mm (f) to PSC-3.5 mm (f), 81 cm, 32 inches
– 85131D1. 4 set, semi-rigid:
85131-60009 one 3.5 mm (f) to 3.5 mm (m), 53 cm,
21 inches,
– 85131-60010 one 3.5 mm (f) to PSC-3.5 mm (f), 53 cm,
21 inches
– 85131E1, 4 single, flexible: 3.5 mm (f) to PSC-3.5 mm (f),
96.5 cm, 38 inches
– 85131F1, 4 set, flexible:
– 85131-60012 one 3.5 mm (f) to 3.5 mm (m), 62.2 cm,
24.5 inches
– 85131-60013 one 3.5 mm (f) to PSC-3.5 mm (f), 62.2 cm,
24.5 inches
– 85131G1, 4 single, semi-rigid: 3.5 mm (f) to 3.5 mm (m),
53 cm, 21 inches
– 85131H1, 4 single, flexible: 3.5 mm (f) to 3.5 mm (m), 62.2 cm,
24.5 inches
– 85134C1 single, semi-rigid: PSC-3.5 mm (f) to 2.4 mm (f),
81 cm, 32 inches
– 85134D1 set, semi-rigid:
– 85134-60002 one 2.4 mm (f) to PSC-3.5 mm (f), 53 cm,
21 inches
– 85134-60001 one 2.4 mm (f) to PSC-3.5 mm (m), 53 cm,
21 inches
– 85134E1 single, flexible: PSC-3.5 mm (f) to 2.4 mm (f),
96 cm, 38 inches
– 85134F1 set, flexible:
85134-60004 one 2.4 mm (f) to PSC-3.5 mm (f), 61 cm,
24 inches
85134-60003 one 2.4 mm (f) to PSC-3.5 mm (m), 61 cm,
24 inches
– 85134G1 single, semi-rigid: 2.4 mm (f) to PSC-3.5 mm (m),
53 cm, 21 inches
– 85134H1 single, flexible: 2.4 mm (f) to PSC-3.5 mm (m),
61 cm, 24 inches
– N4419AK20 single, flexible: 3.5 mm (m) to 3.5 mm (f),
91.4 cm, 36 inches
– Z5623A-K20 single, flexible: 3.5 mm (m) to 3.5 mm (m),
91.4 cm, 36 inches
Adapters
– 11853A 50 Ω Type-N accessory kit.
Includes:
1250-1472 Type-N (f) to Type-N (f) adapter (two included)
1250-1475 Type-N (m) to Type-N (m) adapter (two included)
85032-60009 Type-N (f) short
85032-60008 Type-N (m) short
– 11878A Type-N to 3.5 mm adapter kit.
Includes:
1250-1744 3.5 mm (f) to 50 Ω Type-N (m) adapter
1250-1743 3.5 mm (m) to 50 Ω Type-N (m) adapter
1250-1745 3.5 mm (f) to 50 Ω Type-N (f) adapter
1250-1750 3.5 mm (m) to 50 Ω Type-N (f) adapter
– 11524A 7 mm to Type-N (f) adapter
– 11525A 7 mm to Type-N (m) adapter
– 85130C1 3.5 mm to Type-N
Includes:
85054-60029 NMD-3.5 mm to Type-N (f)
85054-60030 NMD-3.5 mm to Type-N (m)
– 85130D1 3.5 mm to 3.5 mm
Includes:
85130-60005 NMD-3.5 mm to PSC-3.5 mm (f)
85130-60006 NMD-3.5 mm to PSC-3.5 mm (m)
– 85130F1 2.4 mm to 3.5 mm
13 | Keysight | E5071C Network Analyzer - Configuration Guide
1. For this option order K281C-012.
For devices with 75 Ω Type-N connectors
Mechanical calibration kits
– 85036B DC to 3 GHz, includes:
00909-60019 75 Ω Type-N (m) broadband load
00909-60020 75 Ω Type-N (f) broadband load
85036-60012 75 Ω Type-N (m) short
85036-60011 75 Ω Type-N (f) short
85032-60007 75 Ω Type-N (m) open
85032-20001 75 Ω Type-N (f) open body
85036-60010 75 Ω Type-N (f) open center conductor
extender
85036-60013 75 Ω Type-N (m) to (m) adapter
85036-60014 75 Ω Type-N (f) to (f) adapter
85036-60015 75 Ω Type-N (m) to (f) adapter
– 85036E DC to 3 GHz, includes:
00909-60019 75 Ω Type-N (m) broadband load
85036-60016 75 Ω Type N (m) combined open/short
Adapters
– 11852B Minimum-loss pad
Option 11852B-004 Type-N connectors, 50 Ω (m) to 75 Ω (f)
Calibration must be done with a 75 Ω calibration kit
using an 11852B minimum-loss pad, and impedance conversion
to 75 Ω using the ENA’s fixture simulator function is required.
For devices with waveguide
Mechanical calibration kits
X Band
– X11644A standard, WR-90: 8.2 to 12.4 GHz.
Includes:
00896-60008 X-band standard section
00910-60003 X-band termination
11644-20018 X-band short
11644-20021 X-band shim
– 85132F cable set (set of 2, flexible 7 mm to 3.5 mm, 62.9 cm
each, 24.75 inches each)
– 85135F cable set (set of 2 , flexible, 7 mm to 2.4 mm, 53 cm
each, 21 inches each)
– X281C adapter (included in calibration kit): WR-90 to 7 mm
P Band
– P11644A standard, WR-62: 12.4 to 18 GHz.
Includes:
00896-60007 P-band standard section
00910-60002 P-band termination
11644-20017 P-band short
11644-20020 P-band shim
– 85132F cable set (set of 2, flexible, 7 mm to 3.5 mm, 62.9 cm
each, 24.75 inches each)
– 85135F cable set (set of 2, flexible, 7 mm to 2.4 mm, 53 cm
each, 21 inches each)
– P281C adapter (included in calibration kit): WR-62 to 7 mm
K Band
– K11644A standard, WR-42: 18 to 26.5 GHz.
Includes:
00896-60006 K-band standard section
00910-60001 K-band termination
11644-20016 K-band short
11644-20019 K-band shim
– 85134F cable set (set of 2, flexible, 3.5 mm to 2.4 mm, 53 cm
each, 21 inches each)
– K281C adapter (included in calibration kit):
WR-42 to 3.5 mm (f)
Option 0121 WR-42 to 3.5 mm (m)
14 | Keysight | E5071C Network Analyzer - Configuration Guide
1. Order the 82357B USB/GPIB interface to control a power meter by the
E5071C.
2. To use the U200x USB power sensors for source power calibration, the
E5071C ENA firmware version A.09.2x or higher is required.
Additional Accessories
Power limiters
– N9355B power limiter, 10 dBm limiting threshold,
10 MHz to 18 GHz, Type-N
– N9356B power limiter, 25 dBm limiting threshold,
10 MHz to 18 GHz, Type-N
– N9355C power limiter, 10 dBm limiting threshold,
10 MHz to 26.5 GHz, 3.5 mm
– N9356C power limiter, 25 dBm limiting threshold,
10 MHz to 26.5 GHz, 3.5 mm
DC blocks
– N9398C DC block, 16 V maximum working voltage,
50 kHz to 26.5 GHz, 3.5 mm
– N9399C DC block, 50 V maximum working voltage,
700 kHz to 26.5 GHz, 3.5 mm
– 11742A, 50 V maximum working voltage, 45 MHz to 26.5 GHz,
3.5 mm
Amplifiers
– 87405B pre-amplifier, 22 dB gain, 10 MHz to 4 GHz
– 87405C pre-amplifier, 25 dB gain, 100 MHz to 18 GHz
– 87415A amplifier, 25 dB gain, 2 to 8 GHz
– 83006A amplifier, 20 dB gain, 10 MHz to 26.5 GHz
Attenuators
– 8491A fixed attenuator, DC to 12.4 GHz, Type-N
– 8493A fixed attenuator, DC to 12.4 GHz, SMA
RF & microwave switches
– N1810TL SPDT switch, terminated, DC to 26.5 GHz
– N1810UL SPDT switch, unterminated, DC to 26.5 GHz
– 87104B SP4T switch, terminated, DC to 20 GHz
– 87106B SP6T switch, terminated, DC to 20 GHz
– 87222C transfer switch, DC to 26.5 GHz
– L7104B SP4T switch, terminated, DC to 20 GHz
– L7106B SP6T Switch, terminated, DC to 20 GHz
– L7222C transfer switch, DC to 26.5 GHz
– P9400C solid state PIN diode transfer switch, 100 MHz to 18 GHz
– P9402C SPDT solid state PIN diode switch, 100 MHz to 18 GHz
– P9404C SP4T solid state PIN diode switch, 100 MHz to 18 GHz
– U9397C SPDT solid state FET hybrid switch, 300 kHz to 18 GHz
– U9400C solid state FET hybrid transfer switch, 300 KHz to 18 GHz
Power meters and sensors1
Recommended for source output power calibration.
– E4416A1 single-channel EPM-P series power meter
– E4417A1 dual-channel EPM-P series power meter
– E4418B1 single-channel EPM series power meter
– E4419B1 dual-channel EPM series power meter
– N1911A1 single-channel P-series power meter
– N1912A1 dual-channel P-series power meter
– 8482A power sensor, 100 kHz to 4.2 GHz, Type-N (m), 100 mW
– E9304A-H18 power sensor, 9 kHz to 18 GHz, Type-N (m), 100 mW
– E4412A CW power sensor, 10 MHz to 18 GHz, Type-N (m), 200 mW
– E4413A CW power sensor, 50 MHz to 26.5 GHz, 3.5 mm (m), 200 mW
– N1921A power sensor 50 MHz to 18 GHz, Type-N (m)
– N1922A power sensor 50 MHz to 40 GHz, 2.4 mm (m)
– U2000A/B/H2 USB power sensor, 10 MHz to 18 GHz, Type-N (m)
– U2001A/B/H2 USB power sensor, 10 MHz to 6 GHz, Type-N (m)
– U2002A/H2 USB power sensor, 50 MHz to 24 GHz, 3.5 mm (m)
– U2004A2 USB power sensor, 9 kHz to 6 GHz, Type-N (m)
Probes
– N1021B 18 GHz differential TDR/TDT passive probe kit
– 85024A high-frequency probe, 300 kHz to 3 GHz
General accessories
System racks
– 1CN005A handle kit, may be ordered as option 1CN (two included)
– 1CM015A rack mount kit, for use without handles: may be ordered as
option 1CM
– 1CP009A rack mount kit, for use with previously supplied handles;
may be ordered as option 1CP
– E3663AC rack mount rail kit, for use with 1CM015A or 5188-4430
– 1181BZ test mobile system cart
Interface cables
The following GPIB cables can be used to connect the network
analyzer with an external device such as a computer
– 10833A GPIB cable, 1.0 m (3.3 ft)
– 10833B GPIB cable, 2.0 m (6.6 ft)
– 10833C GPIB cable, 4.0 m (13.1 ft)
– 10833D GPIB cable, 0.5 m (1.6 ft)
– 82357B GPIB to USB interface, necessary to control a power meter or
signal generator with the E5071C.
Monitors
– XGA-compatible monitor
Printers
– USB printers with Microsoft Windows printer driver
Other
– 8710-1764 WRENCH - TORQUE 8 IN/LB, 20 MM OPEN END
15 | Keysight | E5071C Network Analyzer - Configuration Guide
Upgrade kits
Upgrade kits for the E5071C
Protecting your hardware investment
The E5071C ENA network analyzer is a safe investment because
of its flexibility. Easily upgrade any ENA software or hardware
feature whenever you need that feature.
Ordering instructions
To upgrade an existing E5071C, order the corresponding upgrade
kit model. For further information, visit:
http://www.keysight.com/find/ena_upgrades
Application and product notes
Introduction to the Fixture Simulator Function of the ENA Series
RF Network Analyzers: Network De-embedding/Embedding and
Balanced Measurement, Product Note E5070/71-1 Literature
number 5988-4923EN
Evolution of Test Automation Using Built-in VBA with the ENA
Series RF Network Analyzers, Product Note E5070/71-2
Literature number 5988-6192EN
On-wafer Multiport Calibration Using the ENA Series RF Network
Analyzer with the Cascade Microtech Probing System, Product
Note E5070/71-3
Literature number 5988-5886EN
In-Fixture Characterization Using the ENA Series RF Network
Analyzer with Cascade Microtech Probing System, Product Note
E5070/71-4
Literature number 5988-6522EN
Improve the Circuit Evaluation Efficiency of Wireless LAN
Chip Set Design, Application Note 1463-2
Literature number 5988-9803EN
Impedance Characteristic Evaluation of SMD by Using the ENA
with Inter-Continental Microwave (ICM)
Application Note 1463-5
Literature number 5989-0547EN
Accurate Mixer Measurements Using the Frequency-Offset
Mode, Application Note 1463-6
Literature number 5989-1420EN
7 Reasons to Migrate from Your 8753 to an ENA Network Ana-
lyzer Application Note 1478
Literature number 5989-0206EN
Multiport Solutions for E5071C ENA RF Network Analyzers Using
External Switches
Literature number 5989-7916EN
Advanced Measurement Techniques for RF Amplifiers Using
Unique Functions of the Keysight E5071C ENA
Literature number 5989-6522EN
Measurement Wizard Assistant software for ENA/E5091A
Literature number 5989-4855EN
Comprehensive Multiport Solution for the ENA
Network Analyzer
Literature number 5989-8737EN
E5071C ENA Option TDR Enhanced Time Domain
Analysis Option
Literature number 5990-5237EN
Correlation between TDR oscilloscope and VNA generated time
domain waveform
Literature number 5990-5238EN
Literature and information
ENA Network Analyzers Brochure
Literature number 5989-5478EN
ENA Network Analyzers Data Sheet
Literature number 5989-5479EN
Keysight Network Analyzer Selection Guide
Literature number 5989-7603EN
ENA-L RF Network Analyzers Brochure
Literature number 5989-0167EN
ENA-L RF Network Analyzers Data Sheet
Literature number 5989-0018EN
Test Solutions for Multiport and Balanced Devices
Selection Guide
Literature number 5988-2461EN
Keysight RF & MW Test Accessories Catalog
Literature number 5968-4314EN
Key web resources for additional infor-
mation on the ENA Series, visit:
www.keysight.com/find/ena
16 | Keysight | E5071C Network Analyzer - Configuration Guide
This information is subject to change without notice.
© Keysight Technologies, 2013 - 2015
Published in USA, March 25, 2015
5989-5480EN
www.keysight.com
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of
the PCI Industrial Computer Manufacturers Group.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
(877) 894 4414
Brazil
55 11 3351 7010
Mexico
001 800 254 2440
United States
(800) 829 4444
Asia Pacific
Australia
1 800 629 485
China
800 810 0189
Hong Kong
800 938 693
India
1 800 11 2626
Japan
0120 (421) 345
Korea
080 769 0800
Malaysia
1 800 888 848
Singapore
1 800 375 8100
Taiwan
0800 047 866
Other AP Countries
(65) 6375 8100
Europe & Middle East
Austria
0800 001122
Belgium
0800 58580
Finland
0800 523252
France
0805 980333
Germany
0800 6270999
Ireland
1800 832700
Israel
1 809 343051
Italy
800 599100
Luxembourg
+32 800 58580
Netherlands
0800 0233200
Russia
8800 5009286
Spain
800 000154
Sweden
0200 882255
Switzerland
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-02-20-15)