MaxStream 9XStream-PKG-T Product Manual

File Specifications

Brand: MaxStream
Category: Modem
Model: 9XStream-PKG-T (Product Manual), prW/NUzl8xYDU
File Type: PDF
File Size: —
Pages: 62 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (62 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 05/08/2026).

Read Online

Read the MaxStream 9XStream-PKG-T Product Manual online using the built-in PDF viewer.

Key Pages of Document

XStream-PKG-T™ Telephone RF Modem

XStream Telephone RF Modem RF Module Operation Telephone Module Operation RF Communication Modes Appendices Product Manual v5.x00 XStream RF Modem Part Numbers: X09-001PK…-T… X24-009PK…-T... XH9-001PK…-T... X09-009PK…-T… X24-019PK…-T… XH9-009PK…-T… X09-019PK…-T… XH9-019PK…-T… Reliable 900 MHz & 2.4 GHz Stand-alone RF Modems by MaxStream, Inc. 355 South 520 West, Suite 180 Lindon, UT ...

© 2006 MaxStream, Inc. All rights reserved

No part of the contents of this manual may be transmitted or reproduced in any form or by any means without the written permission of MaxStream, Inc. XStream™, XStream‐PKG‐R™ and XStream‐PKG‐T™ are registered trademarks of MaxStream, Inc. Technical Support: Phone: (801) 765‐988 ...

1. XStream Telephone RF Modem

4 1.1. Key Features 4 1.1.1. Worldwide Acceptance 4 1.2. Product Overview 5 1.2.1. Specifications 5 1.3. External Interface 6 1.3.1. Front and Back Views 6 1.4. Block Diagram 7 1.5. Pin Signals 8 1.5.1. RJ-11 Connector Pin Signals 8 1.5.2. DB-9 Connector Pin Signals 8 2. RF Module Operation 9 2.1. Modes of Operat ...

The XStream-PKG-T RF Modem provides long range data communications and advanced

networking for the expanding RFd2d (Radio Frequency Device-to-Device) segment of the wireless market. Out-of-box, the modem comes configured to sustain long range wireless communications between devices. The modem transfers a standard asynchronous serial data ...

1.2. Product Overview

When networked with other MaxStream Radio Modems (RS-232/485, Ethernet, USB, etc.), the XStream PKG Telephone Modem provides a transparent wireless link between serial devices and telephone modems. The telephone interface extends MaxStream’s over-the-air range with the reach of any PSTN (Public Switched Telephone Network). Figure 1‐01. On‐boa ...

1.3. External Interface

1.3.1. Front and Back Views 1-02a. RJ-11 Connector Figure 1‐02. Front View Standard RJ-11 connector is used to connect to telephone lines. [Pin descriptions are on page 8] 1-02b. DB-9 Serial Port Standard female DB-9 (RS-232) DCE connector is primarily used as a medium to configure RF module and Telephone module parameter values. 1-02c. Powe ...

1.4. Block Diagram

Figure 1‐04. PKG‐T RF Modem Internal Block Diagram (Low‐asserted signals distinguished by horizontal line over pin name.) The PKG-T RF Modem provides a wireless link between devices out-of-box and without configuration. If more advanced features are needed, the XStream RF Module and Telephone Module can be configured via the DB-9 co ...

1.5. Pin Signals

1.5.1. RJ-11 Connector Pin Signals Figure 1‐05. Tip and Ring Pins of the RJ‐11 Connector Table 1‐04. RJ‐11 Signals and their implementations on the XStream‐PKG‐T RF Modem Pin Pin Name Description Implementation 3 T1 Tip Dial-tone and talk circuit 4 R1 Ring Dial-tone and talk circuit 2, 5 not used 1, 6 not connected 1.5.2. DB ...

2.1. Modes of Operation

An on-board RF module enables the XStream-PKG-T RF Modem to send and receive data over- the-air. The RF module operates in five modes. Figure 2‐01. RF Module’s Modes of Operation The modem can only be in one mode at a time. 2.1.1. Idle Mode When not receiving or transmitting data, the module is in Idle M ...

2.1.2. Transmit Mode

When the first byte of serial data is received from the UART in the DI buffer, the modem attempts to shift to Transmit Mode and initiate an RF connection with other modems. Figure 2‐02. Transmission of Dat nsmit a Once in Tra Mode, the nnel. s s, on, buffer. p to 64 e modem initializes a communications cha Channel initialization is the process ...

The header contains network addressing information that is used to filter incoming RF data. The

receiving modem checks for matching a VID, Hopping Channel and Destination Address. Data that does not pass through all three network filter layers is discarded. Figure 2‐04. Filtration Layers Contained in the Header CRC (Cyclic Redundancy Check) To verify dat ...

2.1.4. Sleep Mode

Sleep Modes are not supported by the XStream-PKG-T Telephone RF Modem; however, Sleep Modes can be implemented on remote modems connected to the telephone RF modem host. Sleep Modes enable the XStream Modem to operate at minimal power consumption when not in use. Three Sleep Mode options are available: • Pin Sleep (Host Controlled) • Serial Port Sle ...

The module remains in Sleep Mode for a user-defined period of time ranging from 0.5 seconds to

16 seconds (SM Parameters 3 through 8). After this interval of time, the module returns to Idle Mode and listens for a valid data packet for 100 ms. If the module does not detect valid data (on any frequency), the module returns to Sleep Mode. If valid data is detected, the mod ...

2.1.5. Command Mode

To modify or read RF module parameters, the module must first enter into Command Mode - the state in which incoming characters are interpreted as commands. Two command types are available for programming the on-board RF module: • AT Commands • Binary Commands Refer to the RF Module Con ...

2.2. RF Module Configuration

2.2.1. Command Reference Table Table 2‐01. Commands Unique to the on‐board RF Module (For detailed command descriptions, refer to Appendix B) AT Command Binary Command AT Command Name Range Command Category # Bytes Returned Factory Default AM v4.30* 0x3A (58d) A ...

2.2.2. AT Command Mode

This section illustrates how to configure the on-board RF Module using standard AT Commands. Refer to p17 for programming examples that implement the instructions on this page. Hardware Setup: The on-board RF Module is configured through the DB-9 connector of the PKG-T RF Modem. To configure the on-board RF Module, DIP Switch 2 must be ON (up) and ...

System Response. When a command is sent to the module, the module parses and executes

the command. Upon successful execution of a command, the module returns an “OK” message. If execution of command results in an error, the module returns an “ERROR” message. Multiple AT Commands. Multiple AT commands ...

2.2.3. Binary Command Mode

Sending and receiving parameter values using binary commands is the fastest way to change operating parameters of the XStream RF Modem. Binary commands are used most often to sample signal strength (RS parameter) and/or error counts; or change modem addresses and channels for polling data systems. Since the sending and receiving of register val ...

Binary Command Example

The following example steps through an RF module configuration process using binary commands. To Send Binary Commands: Example: Use binary commands to change the RF Module’s destination address to 0x1A0D and save the new address to non-volatile memory. 1. RT Command must be set to “1” in AT Command Mode to enable binary programming. 2. Asser ...

3.1. Telephone Module Configuration

The Telephone Module features a rich set of AT commands that allow flexibility in operations. On power-up or reset, the Telephone Module operates in command mode and will accept AT commands either from an RS-232 serial cable or from another MaxStream RF Modem (PKG-R, PKG-U, etc.) over a wireless link. Re ...

Related Devices for MaxStream 9XStream-PKG-T:

XBee-PRO PKG-U
MaxStream XBee-PRO PKG-U
16.07.2026 59 pages

MaxStream 355 South 520 West, Suite 180 Lindon, UT 84042 Phone: (801) 765-9885 Fax: (801) 765-9895 [email protected] www.MaxStream.net (live chat support Manual for safe operation of the MaxStream XBee-PRO PKG-U Modem. This manual describes setup, usage, and user instructions, service contacts, diagnostic information.

9XCite XC09-009WNI
MaxStream 9XCite XC09-009WNI
28.08.2026 36 pages

MaxStream 355 South 520 West, Suite 180 Lindon, UT 84042 Phone: (801) 765-9885 Fax: (801) 765-9895 [email protected] www.MaxStream.net (live chat support Professional manual for the MaxStream 9XCite XC09-009WNI Control Unit. It provides guidance on device overview, menu navigation, calibration steps.

9XStream-PKG-T
MaxStream 9XStream-PKG-T
30.04.2026 62 pages

XStream-PKG-T™ Telephone RF Modem XStream Telephone RF Modem RF Module Operation Telephone Module Operation RF Communication Modes Appendices Product Manual v User instructions for the MaxStream 9XStream-PKG-T Modem. The document offers guidance on product handling, detailing setup, safety protocols, safety.

XT09-SI-MESH
MaxStream XT09-SI-MESH
29.08.2026 62 pages

MaxStream 355 South 520 West, Suite 180 Lindon, UT 84042 Phone: (801) 765-9885 Fax: (801) 765-9895 [email protected] www.MaxStream.net (live chat support Technical setup manual for the MaxStream XT09-SI-MESH Modem. This guide presents instructions on wiring setup, firmware installation, internal layout, setup validation.

Xbee-PRO
MaxStream Xbee-PRO
08.06.2026 10 pages

GETTING STARTED Thank you for buying the USB-XBee-Dongle. We hope you will find the USB- XBee-Dongle to be inexpensive, useful, and easy to use as possible. Fig Product documentation for the MaxStream Xbee-PRO Computer Hardware. This manual covers safety, performance optimization, product handling, installation steps.

XCite
MaxStream XCite
12.08.2026 21 pages

XCite™ OEM RF Module XCite OEM RF Module Data Radio System Components RF Module Configuration Appendices Product Manual v1.1 For XCite OEM RF Module Part Numb Setup instructions for the MaxStream XCite Control Unit. The document contains troubleshooting, system setup, device calibration.

XStream
MaxStream XStream
17.05.2026 5 pages

XStream™ OEM RF Module Development Kit Quick Start Guide Introduction Range Test Setup Range Test Execution Tips and Suggestions Contact MaxStream www.maxstre Product usage manual for the MaxStream XStream Microcontrollers. This documentation explains configuration and installation, safety features, usage procedures.

XStream-Pkg
MaxStream XStream-Pkg
29.03.2026 12 pages

69795 XStream-Pkg Wireless Modem Operation Manual Reference manual for the MaxStream XStream-Pkg Modem. This guide describes component overview, safety information, safety, product safety.

Modem: Frequently Requested PDF Instructions

3G Novatek Wireless U760 USB modem
Bell 3G Novatek Wireless U760 USB modem
23.03.2026 16 pages

Product operation guide for the Bell 3G Novatek Wireless U760 USB modem Modem. The documentation includes details on operating modes, performance details, operating instructions.

IF-5200
Furuno IF-5200
19.06.2026 16 pages

VHF INTE R FACE IF-5200 VHFインターフェイス Usage and setup manual for the Furuno IF-5200 Recording Equipment. It includes maintenance procedures and performance details, power management, safety.

RTK Bridge-X
Intuicom RTK Bridge-X
22.07.2026 8 pages

Intuicom, Inc. 4900 Nautilus Ct. Ste. 100 Boulder, CO 80301 (303) 449-4330 www.intuicom.com RTK Bridge® -X Integration with: Topcon® AGI-3® and AGI-4® Insta Stepwise user guide for the Intuicom RTK Bridge-X Network Hardware. The guide outlines procedures for hardware instructions, setup validation, user preferences, setup tips.

IDG400-0TE0C
Protectli IDG400-0TE0C
26.08.2026 33 pages

4G Modem IDG400-0TE0C (LTE cat. 4) User Manual Comprehensive operating guide for the Protectli IDG400-0TE0C Modem. This guide explains technical procedures for performance details, technical guidelines, technical assistance, usage examples.