Danfoss VLT HVAC Operating Instructions Manual

Text of the manual

Frequency converters contain high voltage when

connected to AC mains input power. Installation, start up, and maintenance should be performed by qualified personnel only. Failure to perform installation, start up, and maintenance by qualified personnel could result in death or serious injury. High Voltage Frequency convert

1.1 Purpose of the Manual

6 1.2 Additional Resources 6 1.3 Product Overview 6 1.4 Internal Frequency Converter Controller Functions 6 1.5 Frame Sizes and Power Ratings 8 2 Installation 9 2.1 Installation Site Check List 9 2.2 Frequency Converter and Motor Pre-installation Check List 9 2.3 Mechanical Installation 9 2.3.1 Cooling 9 2.

3.5 Automatic Motor Adaptation

28 3.6 Check Motor Rotation 28 3.7 Local-control Test 28 3.8 System Start Up 29 3.9 Acoustic Noise or Vibration 29 4 User Interface 30 4.1 Local Control Panel 30 4.1.1 LCP Layout 30 4.1.2 Setting LCP Display Values 31 4.1.3 Display Menu Keys 31 4.1.4 Navigation Keys 32 4.1.5 Operation Keys 32 4.2 Back Up and Copying Parameter S

8.4 Warning and Alarm Definitions

54 9 Basic Troubleshooting 62 9.1 Start Up and Operation 62 10 Specifications 65 10.1 Power-dependent Specifications 65 10.2 General Technical Data 71 10.3 Fuse Tables 76 10.3.1 Branch Circuit Protection Fuses 76 10.3.2 UL and cUL Branch Circuit Protection Fuses 77 10.3.3 Substitute Fuses for 240 V 78 10.4 Connection Tighten

Illustration 1.1 Exploded View A Size

1 LCP 10 Motor output terminals 96 (U), 97 (V), 98 (W) 2 RS-485 serial bus connector (+68, -69) 11 Relay 1 (01, 02, 03) 3 Analog I/O connector 12 Relay 2 (04, 05, 06) 4 LCP input plug 13 Brake (-81, +82) and load sharing (-88, +89) terminals 5 Anal

Remove jumper to activate Safe Stop

Max. 24 Volt ! 12 13 18 19 27 29 32 33 20 61 68 39 42 50 53 54 06 05 04 03 02 01 130BB493.10 Illustration 1.2 Exploded View B and C Sizes 1 LCP 11 Relay 2 (04, 05, 06) 2 Cover 12 Lifting ring 3 RS-485 serial bus connector 13 Mounting slot 4 Digital

1.1 Purpose of the Manual

This manual is intended to provide detailed information for the installation and start up of the frequency converter. 2 Installation provides requirements for mechanical and electrical installation, including input, motor, control and serial communications wiring, and control terminal functions. 3 Start Up and Functional Testing pro

• Three-phase AC mains power

supply to the frequency converter 2 Rectifier • The rectifier bridge converts the AC input to DC current to supply inverter power 3 DC bus • Intermediate DC-bus circuit handles the DC current 4 DC reactors • Filter the intermediate DC circuit voltage • Prove line transient protection �

Other Controller Manuals