Fanvil i31S Quick Installation Manual
Read Online
Read the Fanvil i31S Quick Installation Manual online using the built-in PDF viewer.
Text of the manual
Table of Contents
1. Package Contents ......................................................................................... 4
2. Physical Specifications .................................................................................. 4
3. Installation ................................................................................................... 8
4. Searching Door Phone ................................................................................ 11
5. SIP Door Phone Setting ............................................................................... 12
6. Door Unlocking Setting ............................................................................... 13
223 x 130 x 74mm
Weight
1800g
1)
Front Panel
Speaker
Numeric keypad
(password and dialing)
Lock status
Call status
Ring status
Network and registration
status
Dss Key
MICs
Camera
photoresistor
Infrared light
RFID area
Door Phone
Connectors
Quick Installation
Guide
RFID Cards
Mounting Template
Screw and
Wrench
Get the video.
Infrared light &
Photoresistor
The Compensate for lack of ambient light
Speaker
The door phone has a built-in speaker for convenient communication
and alert use.
MIC
The door phone has a built-in microphone hidden in the pinhole located
on the front panel.
RFID Reader
Use RFID cards to unlock the door by touching RFID reader of device.
Button Definition
Button
Description
DSS Key
Press the Button, calling or request to open the door.
Numeric Keyboard
Input password to open the door or call.
LED Definition
LED
Status
Description
Lock
Steady Blue
Door unlocking
off
Door locking
Call
Blinks per second
Hold
Steady Blue
Call Hold
off
On Hook
Ring
Steady Blue
Ringing
off
On Hook
Network & SIP
Registration
Blinks per second
Network error
off
Network is normal, SIP is not registered
Blinks every 3 seconds
SIP Registration failed
Steady Blue
SIP Registration succeeded
2)
Port Definition
After removing the Back Panel of device, there are one terminal block connectors for power and lock
control connection as shown in the picture below.
JP1 Jumper
Power and lock
connector
WAN Port
Power and Electric-lock Connector
1
2
3
4
5
6
7
+DC12V
VSS
NC
COM
NO
S-IN
S-OUT
12V DC Input
Electric-lock switch
Indoor switch
JP1 Jumper
There are two modes for power supply of electric-lock as shown in the picture below.
(The default is “Passive Mode:”).
Passive Mode: When the electric-lock starting current is more than 12V/650mA, need to use the external
drive mode, the electric lock interface for short circuit output control.
Active Mode : When the electric-lock starting current is less than 12V/650mA, can use the internal drive
mode, the electric lock interface is 12V DC output.
Jumper in passive mode Jumper in active mode
NO: Normally Open Contact
COM: Common Contact
NC: Normally Close Contact
Driving Mode
Electric-lock Mode
JP1
Jumper
Connections
Active
Passive
No electricity
when open
Electrify
when open
√
√
√
√
√
√
√
√
√
√
Front Panel Main Part of Intercom Rain Shade Back Panel
Figure 1 Three Major Parts of i31S
Step 1: Installation preparation
A. Check the following contents:
Hex wrench x 1
RJ45 plugs x 2 (1 spare)
TA5 x 40mm screws x 4
35mm screw anchors x4
B. Tools that may be required:
Hex wrench
Phillips screwdriver (Ph2 or Ph3), hammer, RJ45 crimper
Electric impact drill with an 6mm drill bit
Step 2: Drilling
Figure 2 Wall Mounting
A. Place the mounting template with dimensions on the surface of a wall in a desired flat position.
B. Use an electric drill to drill the 4 holes marked on the mounting template. It is recommended to drill
about 50mm deep. Remove the template when finishing drilling.
C. Push or hammer screw anchors into the drilled holes.
Step 3: Removing hanging shell
A. With L-shaped screwdriver, unpack the front panel as diagram (3) (Counter-clockwise) and (4)
Figure 3
Figure 4
B. With Phillips screwdriver, unpack the rain shade and the main part of intercom as diagram (5)
Figure 5
Step 4: Back panel fixing and cabling
Figure 6 Figure 7
A. Select the hole for cable supply, 15cm to 20cm cable length is recommended.
Note: The direction of the cable hole on back panel is pointing down.
B. With 4 TA5*40mm screws, tighten the back panel on the wall as diagram (6).
C. Connect the cables of RJ45, power, and electric-lock to the motherboard socket as mentioned
in connectors description (refer to Section 2).
D. Test whether there is electricity by doing the following:
Press the # button for 3 seconds to get the IP address of intercom by voice.
Input access password or press the indoor switch to check electric-lock installation.
Note: Do not proceed mounting until you have finished the electric checking.
Step 4: Mounting
Figure 8 Figure 9
A. With 6 screws unscrewed before, tighten the main part (together with rain shade) of intercom
on the back panel as diagram (8).
B. Push the front panel into the plastic frame, and tighten it with 6 screws as diagram (9).
Note: Make sure the screws have been tightened properly for better waterproof effect.
4. Searching Door Phone
There are two methods as shown below to search the device.
Method 1:
Open the iDoorPhone Network Scanner. Press the Refresh button to search the device and find the
IP address.
(Download address http://download.fanvil.com/tool/iDoorPhoneNetworkScanner.exe )
Method 2:
Press and hold the “#” key for 3 seconds and the door phone will report the IP address by voice.
In addition device provides the device surface DSS key operation to switch IP address acquisition mode:
long press the DSS key for 10 seconds, to be issued by the speaker Beep, and then press the DSS key
three times, the beep stops. Wait 10 seconds, after the success of the system automatically
broadcast the current IP address.
Default Setting
Default DHCP Client
Enable
Static IP Address
192.168.1.128
Default Web Port
80
Default Login User Name
admin
Default Login Password
admin
Display IP address
Hold # for 3 seconds to display by voice
Search Tools
iDoorPhone Network Scanner
5. IP Door Phone Setting
Step 1: Log in the door phone
Input IP address (e.g. http://192.168.1.149) into address bar of PC’s web browser.
The default user name and password are both admin.
Step 2: Add the SIP account.
Set SIP server address, port, user name, password and SIP user with assigned SIP account parameters.
Select “Activate”, and then click Apply to save this setting.
Step 3: Setting DSS key
Set the DSS key as shown below for a quick start. Click “Apply” to save this setting.
Type: Hot Key
Number 1: The DSS Key will dial to this Number 1.
Number 2: If Number 1 is unavailable, it will be forwarded to Number 2.
Line: Working line
Subtype: Speed dial
Step 4: Door Phone Setting
6. Door Unlocking Setting
Local
1) Local Password
Step 1: Go to EGS Setting → Features → Set Local Password (The default is “6789”).
Step 2: Use the device’s Numeric Keyboard to input password and “#” key, and then the door will be
unlocked.
2) Private Access Code
Step 1: Go to EGS Access → Access Rule → set Access Code.
Step 2: Use the device’s Numeric Keyboard to input password and “#” key, and then the door will be
unlocked.
Remote
Remote Password
Step 1: Go to EGS Setting → Features → Set Remote Password (The default is “*”).
Step 2: To answer the call made by visitor via SIP phone, press the “*” key to unlock the door the visitor.
-
RFID Card
Step 1: Go to EGS Access → Enter the Name and ID Number (Only Front 10 yards) → Press Add to
Access Table.
Step 2: Use pre assigned RFID cards to unlock the door by touching RFID area of device.