SDC EntryCheck 930 Installation Instructions Manual

Brand: SDC
Category: Intercom System
Model: EntryCheck 930 (Installation Instructions Manual)
File Type: PDF
File Size: —
Pages: 12
Text of SDC EntryCheck 930 Installation Instructions Manual

3580 Willow Lane, Westlake Village, CA 91361-4921 • (805) 494-0622 • Fax: (805) 494-8861

www.sdcsecurity.com • E-mail: [email protected] P:\INSTALLATION INST\Access Control\INST-930.vsd 0505 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email [email protected] INSTALLATION INSTRUCTIONS Model 930 EntryCheck™ The 930 EntryCheck™ is an easy to pro

Table of Contents

P:\INSTALLATION INST\Access Control\INST-930.vsd 0505 Page 2 SYSTEM SPECIFICATIONS 3 INPUT REQUIREMENTS 4 OUTPUT CAPABILITIES 4 OPERATING TEMPERATURES 4 PREPARING FOR INSTALLATION 5 SYSTEM COMPONENTS 5 THE INSTALLATION PROCEDURE 5 REQUIRED TOOLS 5 PREPARE THE KEYPAD FOR INSTALLATION 5 INSTALL THE WIRING CABLE 6 CONNECT THE 930 EntryCheck 6 PREPARE THE DOOR FOR THE ELECTRIC STRIKE 6 CONNECTING THE

SDC EntryCheck 930 Input Requirements: 12 to 24V AC/DC

1 to 120 seconds Default 5 seconds One SPDT Relay (2 Amps at 24V max) • Voltage or Dry Contact • Fail Safe or Fail Secure Lock Two ¼ A Grounding Outputs • First key press: 10 sec Output • Press the : 1 sec Output Latching: Programmable Output (Door Open Time) Main Output: CCTV/Light Output: Doorbell Output: 100 mA (Using keypad illumination) Maximum Current Draw: Standby Current Draw: < 10 mA

SDC EntryCheck 930 The 930 EntryCheck™ accepts 12 to 24 Volts AC/DC. System current draw (maximum):

Standby: 10mA at 12/24 Volts During Operation: 100 mA max IMPORTANT: The maximum output current allowed is ½ Amp. Check the specifications of your locking device. Make sure that the locking device draws less than ½ Amp. For locking devices that draw more current, a separate power supply is required. (See Appendix B) Note: If connecting DC, make the connections to the Red a

SDC EntryCheck 930 There are four primary components to be installed:

1. The 930 EntryCheck™ should be mounted on the wall adjacent to the door. It should be on the same side as the door strike and about 4 feet above the floor. 2. The Wiring Harness connects the keypad to a power supply, locking device and auxiliary relays. Included with the system is a 12 inch wiring harness. Splice additional wire to this harness to connect to the power supply, locking device, etc. (See

INSTALL THE WIRING CABLE

1. Drill a hole in the inside wall or ceiling where you want the cable to come through. 2. Splice added cable length to the wires you will be using (Power, locking device, etc. - See Typical System Wiring). Then pull the cable through the hole so the connector end goes to the keypad. Route it so there is minimal cable at the keypad. CONNECT THE 930 EntryCheck™ 1. Attach the wiring connector to the Keypad. 2. Do NOT mount the Keyp

Designed for areas will low ambient lighting, the 930 EntryCheck™ provides nighttime illumination. Keypad

illumination is “ON” by default. This option can be turned “OFF” by cutting the BLUE “Illum” wire loop on the back of the Keypad. * IMPORTANT: If switching voltages higher than 24V, you must use an external relay. The 930’s built-in relay is capable of switching up to 24V. (See Appendix A – Page 11) SETTING OUTPUT

OVERVIEW OF SYSTEM CODE PROGRAMMING

There are TWO levels of codes for the 930 EntryCheck™ system. 1. The Master Code (used by owner/management to open the door and to program User Codes) 2. User Codes (used by guests/personnel to open the door) IMPORTANT: Notes to remember before programming: 1. All codes must be 3 to 8 digits. 2. All codes must be different from each other. Note: The 930 has two digits on each pad. The system reads th

SDC EntryCheck 930 OVERVIEW OF USER CODES

There are a total of 5 User codes that can be programmed into the 930 EntryCheck™. User Codes can vary in length from 3 to 8 digits. Each User Code is programmed into one of 5 User Locations. These Locations are as follows: User # User Location User Code 1 1-1-1 User Code 2 1-1-3 User Code 3 1-1-5 User Code 4 1-1-7 User Code 5

These are a few troubleshooting suggestions to help assist with any problems you may experience. If the problem

continues or is not answered here, please call Security Door Controls (SDC) technical support at 1-800- 413-8783. You may visit SDC on the web at sdcsecurity.com or send question via email: [email protected]. CHANGED OR DELETED A CODE AND THE OLD CODE STILL WORKS Remember the 930 EntryCheck™ has a total of 6 User Codes. Ma

1) The 930 EntryCheck™ is designed to control a 12 to 24V locking

device. To control any voltage higher than 24V, you must switch an external relay. 2) To disable Latching Capability, cut the Green wire loop. 3) To disable Illumination, cut the Blue wire loop. 4) If connecting a Door Monitor switch, cut the BROWN wire loop. 5) For garage/gate operator, remove DC+ Jumper and set Door Open Time to 1 second. 6) To initiate

SDC Intercom System Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
918 ENTRY CHECK

Intercom System #458K65

6 1052 232 01-08-2026
1591U EMLOCK

User Manual: SDC 1591U EMLOCK (E53SZJ, Upd.03-10-2026)

2 863 208 03-10-2026
EntryCheck 930

PDF User Manual (@DOW1L8), SDC EntryCheck 930 Intercom System (12-04-2026)

12 1443 289 12-04-2026
926 EntryCheck

926 EntryCheck Installation instructions manual - 8I158Y

7 201 37 14-07-2026
01-DE Exit Check

PDF Guide (@7RAUPW), SDC 01-DE Exit Check Intercom System (05-08-2026)

12 375 83 05-08-2026
S6000DE

#S554H7: S6000DE Intercom System Installation instructions manual

12 1080 173 12-08-2026
EntryCheck 920P

EntryCheck 920P (Intercom System ePDF User Guide, #DW34LA)

8 732 169 15-05-2026
55-ABC

SDC 55-ABC Manual (Installation instructions), @1RQDUB

4 998 150 03-09-2026

Intercom System: Similar Manuals