Fluke 05-450 Operation & User’s Manual
Read Online
Read the Fluke 05-450 Operation & User’s Manual online using the built-in PDF viewer.
Key Pages of Document
© 2014 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. 05-450 Digital Doorway Monitor Users Manual ...
Fluke Biomedical warrants this instrument against defects in materials and workmanship for one year from the date of original purchase OR two years if at the end of your first year you send the instrument to a Fluke Biomedical service center for calibration. You will be charged our customary fee for such calibration. During the warranty period, we will repair or at our option replace, at no charge, a product that proves to be ...
Copyright 2014, Fluke Biomedical. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without the written permission of Fluke Biomedical. Copyright Release Fluke Biomedical agrees to a limited copyright release that allows you to reproduce manuals and other printed materials for use in service training programs and other technical publications ...
be calibrated at least once every 12 months. Calibration must be done by qualified personnel. Contact your local Fluke Biomedical representative for calibration. Certification This instrument was thoroughly tested and inspected. It was found to meet Fluke Biomedical’s manufacturing specifications when it was shipped from the factory. Calibration m ...
Title Page Introduction ............................................................................................ 1 Safety Information ................................................................................. 3 Symbols ................................................................................................. 4 General Specifications ....................................................................... 5 Driver Op ...
Optional Remote Alarms ............................................................... 18 Maintenance .......................................................................................... 18 Cleaning Instructions and Precautions .............................................. 18 Replacement of Mains Fuse ..................... ...
Figure Title Page 1. Front Panel ................................................................................................ 2 2. Left Side-Panel .......................................................................................... 7 3. Alarm Point Notice ..................................................................................... 8 4. Typical Installation 385x442 .................................................. ...
designed to monitor for nuclear radiation. Featuring a wall-mount chassis, the Product has a four-digit LED display that is readable from 9 m (30 ft) away. Backlit indicators warn of low radiation alarm (yellow), high radiation alarm (red), instrument failure (red) and low battery (yellow). A green status light is a positive indication of instrument operation. Parameters a ...
Safety Information 3 Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. Warning To prevent possible electrical shock, fire, or personal injury: • Read all safety information before you use the Product. • Carefully read all instructions. • Do not use the Product ar ...
replace battery. • Do not touch the circuit board in the calibration window due to potential for electric shock. • Do not touch the center pin of the detector connector unless the unit has been turned off and power has been removed or at least 1 minute. • To prevent contact with internal hazardous live parts that are accessible using a tool: turn off the Product and d ...
General Specifications 5 General Specifications Detectors .................................................................. Two 7.6 cm x 2.5 cm (3 in x 1 in) thick, shielded NaI (T1) scintillation detectors with up to 200 ft cables (NEMA 4x enclosures included.) Display ...................................................................... 4-digit LED display with 2 cm (0.8 in.) character height Display Range ..................... ...
-40 °C to 65 °C (-40 °F to 150 °F) Maximum relative humidity .................................... Less than 95% (non-condensing) Size Electronics (H x W x D) .......................................... 24.6 cm x 18.7 cm x 6.4 cm (9.7 in x 7.4 in x 2.5 in) Detectors (H x W x D) ............ ...
Getting Started 7 Getting Started The Product is designed for ease of use. This section of the manual is designed to help the first-time user get started. Initial power-up and basic features of the instrument are contained in this section. Other sections of the manual provide more detailed information Power Up Plug the power cord into a suitable wall (Mains) outlet. Note The Product will normally be wired internally for 120 V ac. If ...
to conform to your requirements. The factory-set alarm points may be incorrect for your use. Refer to the instrument manual for more information on setting alarm points. FAILURE TO RESET THE ALARM POINT(S) MAY RESULT IN EXCESSIVE ALARMS OR LACK OF SENSITIVITY. huk02.eps Figure 3. Alarm Point Notice Initial power-up will momentarily activate the internal front-panel lights, sound the aud ...
Getting Started 9 Setting Alarm-Points The LOW ALARM and HIGH ALARM points can only be changed while the instrument is in calibration mode. Switch the top dipswitch CAL MODE (behind the calibration cover) to the right to place the instrument into calibration mode. Changing alarm points is done by holding down the corresponding parameter key and pressing the up or down arrow buttons. Alarm points can be set in the range of 0.1 to 999 ...
Calibration Controls Remove the calibration cover to expose the calibration controls. The calibration controls include the up/down buttons, five calibration potentiometers, and the option dipswitch (detailed in the following subsection). The five potentiometers are detailed below: Warning To prevent possible electrical shock, fire, or personal injury: • To prevent contact with internal hazardous li ...
Operator Controls and Setup 11 Dipswitch (under calibration cover) When the calibration cover is removed, a four-pole dipswitch is accessible that can activate or deactivate options. These four options are: CAL MODE, LATCH ALARM, RANGE, and SINGLE BEEP. • Dipswitch 1: Switching the top CAL MODE switch to the right places the instrument into calibration mode. Parameters can only be changed while the instrument is in calibration mod ...
data onto pin 4 of the 9-pin connector every 2 seconds. An example program which shows how an IBM compatible PC can be used to collect the data follows: ‘Demonstration Program ‘Model 05-450 communication program written for QuickBasic ‘This program causes the computer screen to display the data being dumped from the Model 05-450. ‘Needs t ...
Related Devices for Fluke 05-450:
January 2014 © 2014 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their resp Complete operating guide for the Fluke 714B Test Equipment. This guide explains technical procedures for device overview, replacement parts, device safety checks.
© 2009 DH Instruments, a Fluke Company PPCH™ Hydraulic Pressure Controller/Calibrator Ver. 1.01f and higher Operation and Maintenance Manual User support guide for the Fluke PPCH - V1.01 Other. It outlines installation and specifications, technical troubleshooting, device safety checks, service instructions.
Technical Data • Two separate channels; measure, source and view process signals simultaneously • Measure volts, mA, RTDs, thermocouples, frequency, and res Operating handbook for the Fluke 726 Accessory. This manual outlines safety information, installation procedures, device instructions.
® 1520 MegOhmMeter Calibration Manual PN 1592594 November 2000 © 2000 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks Complete usage guide for the Fluke 1520 Multimeter. It details device setup and service instructions, installation, diagnostic information, installation steps.
© 2009-2018 Fluke Corporation, All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective c Complete user documentation for the Fluke 925 Measuring Instruments. The manual contains instructions for dimensions and layout, error codes, firmware updates, basic operation.
Victoreen® 05-437 Primalert® 35 Area Radiation Monitor Operators Manual March 2005 Manual No. 126011 Rev. 3 ©2003, 2005 Fluke Corporation, All rights reserv Product reference manual for the Fluke Victoreen 05-437 Operators Monitor. The document contains menu navigation, user instructions, product safety, user preferences.
Installation Edition June 2016 VIB 9.520.G Translation of the German manual VIBRONET® Signalmaster This manual is valid for: VIBRONET Signalmaster, Standard Installation instructions for the Fluke VIBRONET Signalmaster Measuring Instruments. The document explains installation steps, system checks, firmware updates, adjustment procedures.
I PM3370B - PM3380B - PM3390B PM3384B - PM3394B Autoranging CombiScope Instrument Service Manual 4822 872 05372 3/1-Dec-00 Warning: These servicing instructi General instruction manual for the Fluke PM3370B Test Equipment. It explains installation, setup, and connectivity setup, maintenance guidelines, software updates.
Measuring Instruments: Frequently Requested PDF Instructions
User Manual Earth Resistance and Resistivity Tester Model GRT350 Additional User Manual Translations available at www.extech.com www. .com informati Complete instruction guide for the Extech Instruments GRT350 Measuring Instruments. It explains configuration options and technical assistance, software configuration, adjustment procedures, safety guidelines.
Professionally approved products. Instruction Manual 3 Phase Multi-function Power Meter 1/5A MID DIN Rail Power Meter. UK MID User instruction manual for the ROHS 871-8308 Measuring Instruments. The document includes installation, technical assistance, performance details, installation steps.
Trademark of the DVB - Digital Video Broadcasting Project Find the user's manual on the download area at: www.promaxelectronics.com FRONT VIEW 1 2 3 4 “F” m Maintenance and service manual for the Promax 8 SE Measuring Instruments. The guide explains operation and maintenance procedures, system parameters, power requirements, regulatory notices.
MADE IN USA ULTRA-TRAC® APL finds unmarked underground pipe fast and accurately! Innovative Detection Solutions Locates Plastic Pipe! Locates Plastic Pipe! www Professional operation guide for the SENSIT Technologies ULTRA-TRAC APL Measuring Instruments. The guide covers usage and diagnostic information, troubleshooting, wiring setup.