Hartenberger mega compact User Manual Manual
Read Online
Read the Hartenberger mega compact User Manual Manual online using the built-in PDF viewer.
Key Pages of Document
2 CONTENTS SAFETY WARNING................................................................................ 2 GUARANTEE. ....................................................................................... 2 APPLICATIONS...................................................................................... 2 ARTICLE DESCRIPTION................................................. ...
3 ARTICLE DESCRIPTION SIDE VIEW, EXTERNAL 1. Front Seal 2. Housing/Body 3. Rear Screw Fitting 4. Button pad – (minus) 5. Cover screw 6. Transport lock 7. LCD Display 8. Button pad + (plus) 1 2 3 Diagram 1 4 5 6 7 8 Diagram 2 FRONT SEAL The front glass plate with the O-Ring is pressed into the housing during the assembly by t ...
4 POWER PACK MEGA 1. Halogen Bulb 2. Reflektor 3. O-Ring 4. Charging Socket 5. Cell Pack 6. Plug-In Connection 1 2 3 4 5 6 Diagram 3 POWER PACK MEGA D2 1. D2 Gas discharge xenon lamp 2. Reflektor 3. O-Ring 4. Gas Discharge Elektronic 5. Charging Socket 6. Cell Pack 7. Plug-In Connection 1 2 3 4 ...
5 TECHNICAL SPECIFICATIONS APPROX. BURN TIME INCL. WARNING BLINKS IN MINUTES WITH NMH CELL PACK 14.4V / 4,5AH Halogen Bulb 30W 50W 100W* D2 35W** Time of use at 25% setting 390 Min. 260 Min. 120 Min. Time of use at 50% setting 210 Min. 130 Min. 60 Min. Time of use at 75% setting 150 Min. 95 Min. 40 Min. 90 Min. Time of use at 100% setting 110 Min. 65 Min. 30 Min. 70 Min. Time ...
6 REAR SCREW FITTING OPENING THE SCREW FITTING The housing is opened by unscrewing the fitting anti-clockwise, (thread length approx. 10 mm [3/8“]). Whilst opening the housing, it should be held in an upright position, thus preventing the power pack from inadvertently falling out. CLOSING THE HOUSING Before closing the housing, all threads, sealing surfaces and seals must b ...
7 two stowage housings for spare halogen bulbs. The charging socket is located behind an opening on the outside of the power pack. On the rear side of the power pack are the 4 contact plugs for the electronic module. SPARE HALOGEN BULB(S) Under the reflector module in the front of the power pack there are two stowage housings for spare halogen bulbs. These are accessed by tur ...
8 To operate the lamp, individual preferences can be selected in different programmes (except for use with D2 gas discharge module). The programme set appears in the top right hand corned of the display when both switches are pressed simultaneously. (A,B,C, or T). If both switches (+/-) remain pressed, the programme will change approx. every 3 seconds to the next programme, ( ...
9 Constantly turning the lamp on and off will also reduce the life expectancy of the bulb. DIGITAL DISPLAY The percentage power setting of the halogen bulb is shown in the top line of the display. The resulting remaining burn time at this setting is shown in minutes in the lower line of the display. The remaining burn time can vary up to 1 or 2 minutes due to technological re ...
10 imminent end of the burn time and that the display is showing an incorrect value. When the lamp is being used with a standard halogen bulb, the user will be warned by the lamp blinking 6 times and subsequently automatically switching over to 25% power. The remaining burn time is approx. 2 minutes. The display blinks continuously until the lamp is turned off. In gas dischar ...
11 data in the memory shows correct handling of the cells, a warranty repair or a fair offer will be made. DISPLAY CORRECTION • If the display does not show 100% charge status after a correct charging cycle (charger has turned itself off and the cells are warm), then a re-calibration of the state of charge display is recommended to establish a 100% state of charge in the di ...
12 sighted. OVER-VOLTAGE / DIMMER The HLX bulbs which we use have a much greater efficiency than standard halogen bulbs. Using a 12 cell power pack, we have a power supply of 14.4 volts. This allows the 12v bulb to be operated continuasly with an over-voltage of approx. 12.8 volts. The electronics switch the bulb on slowly thus preventing the coil in the bulb from burning out ...
13 During the rinsing, the switches must be frequently operated to ensure contamination (salt water and/or sediment) is rinsed out of the mechanism. • Check the lamp immediately after the dive for evidence of a possible flooding of the housing. Should the housing have flooded then refer to the problem diagnosis on page. • The cells should be charged as soon as possible af ...
14 Regularly check the cells for signs of corrosion or gas leakage, (the protective skin showing signs of bubbling, floury or white residue between the cells or in the housing, corrosion around the charging socket.) Should you discover signs of leakage or corrosion, return the lamp immediately to the manufacturer. CHARGING INTRODUCTION IN THE CHARGING OF NICKEL METAL HYDRIDE ...
15 contaminated with dust or dirt, then we recommend that the cell pack should be removed from the rear screw fitting, and that the housing is subsequently closed protecting the O-Rings and the sealing surfaces which would otherwise be exposed to possibly contamination. Stand the power pack in an upright position with the reflector down. This will avoid the collection of dirt ...
16 Do not operate the lamp immediately after the charging cycle is completed. Do not point the lamp at yourself or in the direction of other persons. Maximum cells Charging times using an Off-Shore I/12 Charger for fully discharged Lamp Type Voltage/Capacity Charger Charging time mega compact 14.4v / 4.5Ah Off-Shore I/12 approx. 5 hrs Off Shore II Charger This charger utilise ...
17 CARE AND MAINTENANCE HOUSING We recommend that from time to time the housing surface is impregnated with silicone. The chance of calcium depositing on the surface of the lamp is reduced and the scratch resistance properties of the housing surface are also improved. SERVICE Action to be taken Interval By Owner Workshop Impregnate Housing surface After repeated use X Visual ...
18 FAULT DIAGNOSIS Problem Cause Action to be taken Water enters the housing: Defective or contaminated O-Ring. Abort the dive as soon as is safely possibly. Open the lamp. 1. A few drops are present. 1. Dry the lamp and power pack with a clean cloth. 2. Housing is flooded with fresh water. 2. Dry the power pack and return it to the manufacturer 3. Housing is flooded with Sal ...
19 SPARE PARTS O-Ring Dimensions Elasticity Material Glass 68x3.0 50°shore Viton, Blue Window LCD 58x3.5 50°shore Viton, Blue Screw Fitting 68x3.0 50°shore Viton, Blue Screw Fitting 68x2.0 50°shore Viton, Blue Reflektor unit 68x3.0 50°shore Viton, Blue Reflektor unit 68x2.0 50°shore Viton, Blue Heat protection shield 20x2.0 50°shore Viton, Red Halogen Bulb G6.35 12V/30 ...