SuperBus® 2000 Phone Interface/Voice Module

Installation Instructions Product Summary The SuperBus 2000 Phone Interface/Voice Module (PIV) adds phone and voice functions to Concord™ panels. The module provides on-site and remote system control from any touch-tone telephone, allowing access to both installer and user operations for easy panel access from any location. An on-board digital-voice chip is used to “speak” system status messages over phones and speakers connected to the module. The module provides phone control of one single or multi- ple-partition Concord panel. With multiple panel partitions, one module may be used per partition, with each module connected to a separate phone line. The module communicates with the panel through bus connections and is powered by the panel 12 VDC supply. SuperBus 2000 vs. SuperBus Compatible panels (SuperBus 2000) have the ability to auto-address module unit numbers. When the panel is pow- ered up, the panel automatically reads the unique SuperBus 2000 device ID number and assigns a unit number to the module. This eliminates manually setting DIP switches and the chance of identical unit number conflicts. Non-Compatible panels (SuperBus) communicate with SuperBus 2000 modules but require the module unit num- ber to first be set manually using dip switches. SuperBus 2000 Panels K Concord (software versions 2.0 and later) SuperBus Panels K Concord (software versions 1.0–1.6) Features The module features the following: K User-adjustable status speaker volume control. K On/Off hook detection. K Extensive 220+ word vocabulary. K In-panel cabinet or optional wall mounting. K Backward compatibility with Concord panels software versions 1.0–1.6. Figure 1 shows the main module components and Table 1 describes them. Figure 1. Main Module Components Table 1: Module Component Descriptions Component Function Status LED Flashes to indicate normal communication with the panel bus. Unit Number DIP Switches Used for manually setting unit numbers (Concord software versions 1.0–1.6). Wiring Terminals Provide panel, speaker, and telephone connections. SuperBus 2000 Device ID Number Label Identifies the unique device ID number (SuperBus 2000 panels). Software Version Label Identifies the installed module software version. 8998G07B.DSF � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � ��������� ������������� ���������������������� ITI Part No. 60-777-01 Document Number: 466-1516-01 Rev. A August 2000 8998g18A.DSF

SuperBus® 2000 Phone Interface/Voice Module

Installation Guidelines Installation Guidelines Use the following guidelines when installing the module: K Concord systems allow a maximum of one Phone Inter- face/Voice Module per partition. On multiple partition systems, each module must be connected to a separate phone line and speaker. K Always connect the phone line using an RJ-31X jack. This gives the customer the ability to unplug the system from the phone line, in case the system malfunctions and the customer needs to use the phone. K Mount the module inside the cabinet or wall-mount using the optional plastic housing (part no. 60-800). K Use 4-conductor, 22-gauge or larger stranded wire to connect the module to the panel. K Although the module can be located up to 120 feet from the panel (using 18-gauge or larger wire), it is rec- ommend that the module be mounted as close as possi- ble to the panel. K All bus modules must be set with a different bus unit number (set manually on Concord panels with software version 1.0–1.6). K The module draws a maximum 600 mA from the panel power supply. K Do not exceed the total panel power when using panel power for bus and hardwired device power (refer to the specific panel Installation Instructions). Tools and Supplies K Screwdrivers (small blade) K Drill with bits K Wire cutter/stripper K Screws and anchors (included) K Optional plastic housing (part no. 60-800) for wall-mounting (not included) K 4-conductor, 22-gauge or larger stranded wire K RJ-31X Phone Jack (not included) K DB-8 Cord (included with Concord cabinet) K Support standoffs (included with Concord cabinet) Installation Installation consists of mounting the Phone Interface/Voice Module inside the panel cabinet or on a wall. CAUTION To prevent damaging the panel or module, remove the Panel AC power transformer and disconnect the backup battery before installation. CAUTION You must be free of all static electricity when handling electronic components. Touch a grounded bare metal surface before touching the circuit board. To mount the module in a Concord panel cabinet: 1. Remove AC panel power and disconnect the backup battery. 2. Install the support standoffs (included with panel) at the panel locations shown in Figure 2. Figure 2. Installing Panel Support Standoffs 3. Slide the top of the back-plates onto the top left and center module mounting clips on the panel cabinet (see Figure 3). Figure 3. Mounting the Module Inside the Panel Cabinet 8573107A.DSF SUPPORT STANDOFFS 8998G11A.DSF SUPERBUS MODULE MOUNTING CLIPS (6) CARD ON MODULE BACK- PLATES PANEL CABINET (COVER NOT SHOWN) DETAIL SUPPORT STANDOFF

SuperBus® 2000 Phone Interface/Voice Module

Wiring 4. Lift back-plate assembly until it rests on the left cabinet wall tab (not shown) and standoffs align into lower back-plate holes (see detail in Figure 3). To mount the module on a wall using the optional plastic housing: 1. Loosen the two cover screws and lift the cover up and off. Set the cover aside (Figure 4). Figure 4. Removing the Cover Screws and Cover 2. Place the back-plate on the wall at the desired location, check for level, and mark the mounting holes (see Fig- ure 5). Figure 5. Wall Mounting Hole Locations 3. Drill holes, install anchors where studs are not present, and secure the back-plate to the wall with screws. 4. Drill holes for wires at any of the three wire access locations (see Figure 5). 5. Carefully, remove the circuit board from its original back-plates. 6. Install the circuit board onto the housing back-plate (top first), then gently press on the bottom until the board snaps under the card latches (Figure 4). Wiring Wiring consists of the following: K Running Required Wires— for power, bus, speaker, and phone line connections. K Installing an RJ-31X Jack—for phone line connections. K Wiring connections for modules in Concord systems. Running Required Wires 1. Run a 4-conductor, 22-gauge or larger, stranded wire from the module to the panel for power and bus con- nections (see Table 2 for limits). 2. Run a 2-conductor, 22-gauge or larger, stranded wire cable from the module to the speaker location. 3. Run a 4-conductor, 22-gauge or larger, stranded wire cable from the RJ-31X jack location to the telephone protector block. Installing an RJ-31X Phone Jack Use the following guidelines when installing an RJ-31X phone jack. K Locate the RJ-31X jack (CA-38A in Canada) no further than five feet from the panel (or module for partition 2 installations). K The panel (or module) must be connected to a standard analog (loop-start) phone line that provides 48 volts DC (on-hook or idle) which increases between 89 to 130 volts DC when the line is ringing. Note The panel (or module) cannot be used on a digital or PBX phone line. These systems are designed for digi- tal type devices only, operating anywhere from 5 volts DC and up. The panel uses an analog modem and does not have a digital converter, adapter, or interface to operate through such systems. K For full line seizure in partition 1, install an RJ-31X phone jack on the premises phone line so the panel is ahead of all phones and other devices on the line. This allows the panel to take control of the phone line when an alarm occurs, even if the phone is in use or off-hook. Note The Phone Interface/Voice Module does not seize the line during an alarm. 8998G13A.DSF COVER SCREWS (2) BACKPLATE CIRCUIT CARD COVER CARD LATCHES (2) 8998G08B.DSF WIRE ACCESS (3) MOUNTING HOLES WIRE CHANNELS (3) Table 2: Maximum Lengths (module to panel) Wire Gauge Maximum Length 18 120 feet 22 40 feet

SuperBus® 2000 Phone Interface/Voice Module

Wiring K If an analog line is not available, contact your custom- ers’ telecommunications specialist and tell him/her you need an analog line off the phone switch (PBX main- frame) or a 1FB (standard business line). Note Connecting the panel (or module) to an analog line off the phone switch places the panel (or module) ahead of the phone system, preventing system access from phones on the premises. However, the system can still be accessed from off-site phones. To install an RJ-31X jack: 1. Run a 4-conductor cable from the TELCO protector block to the jack location (see A in Figure 6). 2. Connect one end of the cable to the jack (see B in Fig- ure 6). 3. At the TELCO protector block, remove the premises phone lines (lines from phone jacks on premises) from the block and splice them to the black and white (or yellow) wires of the 4-conductor cable (see C in Fig- ure 6). 4. Connect the green and red wires from the 4-conductor cable to the TIP (+) and RING (-) posts on the block (see D in Figure 6). Figure 6. Connecting an RJ-31X Jack to the Phone Line Wiring Connections for Concord Panels Wiring for Concord systems consists of wiring for power, bus, speaker, and phone line. Use the figures below for wir- ing to the designated partition. CAUTION To prevent damaging the panel or module, remove the Panel AC power transformer and disconnect the backup battery before wiring. Wiring—Power and Bus Partition 1 and 2 Figure 7. Wiring the PIV to the Panel Power and Bus Terminals Wiring—Phone Line Note Partition 1 and Partition 2 must be wired to separate phone lines. Partition 1 Figure 8. Wiring the PIV to a Phone Line (Partition 1) BRN GRY GRN RED RED WHITE (OR YELLOW) BLACK 8573G84A.DSF TELCO PROTECTOR BLOCK GREEN RED RING (-) RJ-31X PHONE LINE WIRE RUN GREEN RED TIP (+) LINES FROM PHONES ON PREMISES RJ-31X JACK GREEN BLACK WHITE (OR YELLOW) A B C D 8573108A.dsf � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3 4 5 6 +12V A B GND BUS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 8573109A.dsf BRN GRY GRN RED GREEN BROWN GRAY RED DB-8 CORD 25 26 27 GRY RED RJ-31X JACK PLUG 24 GRN BRN

SuperBus® 2000 Phone Interface/Voice Module

Setting the Unit Number Partition 2 Figure 9. Wiring the PIV to a Phone Line (Partition 2) Wiring—Speakers Partition 1 Note Do not connect speakers to panel if terminals 7 and 8 are connected to PIV terminals 8 and 9 as shown in Figure 10. Figure 10. Wiring a speaker to the PIV (Partition 1) Partition 2 Figure 11. Wiring a Speaker to the PIV (Partition 2) Setting the Unit Number Each bus module connected to the panel must have a different unit number for correct communication. Setting the Unit Number on Concord Panels with Software Versions 1.0–1.6 The module can be set to any unit number 0–15, using the module dip switches. The default setting (0) can be used if no other bus modules are installed in the system. When using one module per partition, the lower unit num- ber will be assigned to partition 1, while the higher unit number will be assigned to partition 2. Note Do not use module unit number 15 if it is installed in a Concord RF system since the built-in receiver is fac- tory set to unit number 15 and cannot be changed. To set the module unit number: Locate the DIP switches on the module circuit board (see Figure 1) and set them to the desired unit number (0–15) before applying power (see Figure 12). Note DIP switches 1–4 are not used and must remain off. � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 8684G01A.DSF BRN GRY GRN RED GREEN BROWN GRAY RED DB-8 CORD RJ-31X JACK PLUG 8573130A.DSF � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7 8 � � � � � � � NOT USED � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 8690G28A.DSF � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � NOT USED � � � � � � � � � � � � � � � � � � � � � � � � � � � � �

SuperBus® 2000 Phone Interface/Voice Module

Power Up and Bus Communication Figure 12. Unit Number DIP Switch Settings Setting the Unit Number on Concord Panels with Software Version 2.0 or Later The unit number will be automatically set when powering up the system. When using one module per partition, the panel automatically assigns each module with a partition number. Power Up and Bus Communication Use the following procedures for powering up the system and verifying bus communication. Note In order to enter panel program mode to verify unit numbers, an alphanumeric touchpad must be con- nected to all Concord panels. To power up panel and Phone Interface/Voice Module: 1. Verify that all wiring at the panel and the module is cor- rect. 2. Connect the panel backup battery and plug in the panel AC power transformer. 3. Verify that the module status LED is on and flashing. 4. If desired, enter panel program mode to verify the unit number exists and the module is enrolled into the cor- rect partition (see panel Installation Instructions for more information). Note If the status LED is not on and flashing, unplug the panel AC power transformer, disconnect the backup battery, and see “Troubleshooting.” Changing the Module Unit Number (software versions 1.0–1.6) Note Whenever the module unit number is changed, you must remove the panel AC power transformer and backup battery, then reconnect them for the panel and module to communicate successfully. Use the following guidelines when changing unit number assignments to avoid communication conflicts between bus devices and the panel: K Whenever possible, assign alphanumeric touchpad unit numbers before all other panel programming. K All unit numbers must be set before applying power and entering program mode. To change the PIV module unit number: 1. Remove panel AC power transformer and disconnect the backup battery. 2. Change the DIP switch setting on the module (see Figure 12). Remember, the setting must be different from all other bus devices. 3. Connect the panel backup battery and plug in the AC power transformer. The panel automatically scans all bus devices and learns any new settings. 4. The system may still indicate a bus failure if the panel learned a unit number that is no longer assigned to any bus device. To clear the failure, enter program mode and locate the unused unit number (under BUS DEVICES) and delete it by pressing D. Please refer to the panel Installation Instructions for more information on deleting bus devices. 5. Exit from program mode. The touchpad and all other bus devices should operate correctly and any bus failures should be cleared. Programming and Testing For complete module/panel programming, operating, and testing information, refer to the panel Installation Instruc- tions and Owner’s Manual. 8573G12C.DSF ADDRESS 0 1 2 3 4 5 6 7 8 ON ADDRESS 1 1 2 3 4 5 6 7 8 ON ADDRESS 2 1 2 3 4 5 6 7 8 ON ADDRESS 3 1 2 3 4 5 6 7 8 ON ADDRESS 4 1 2 3 4 5 6 7 8 ON ADDRESS 5 1 2 3 4 5 6 7 8 ON ADDRESS 6 1 2 3 4 5 6 7 8 ON ADDRESS 7 1 2 3 4 5 6 7 8 ON ADDRESS 8 1 2 3 4 5 6 7 8 ON ADDRESS 9 1 2 3 4 5 6 7 8 ON ADDRESS 10 1 2 3 4 5 6 7 8 ON ADDRESS 11 1 2 3 4 5 6 7 8 ON ADDRESS 12 1 2 3 4 5 6 7 8 ON ADDRESS 13 1 2 3 4 5 6 7 8 ON ADDRESS 14 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON ADDRESS 15--Do not use in Concord RF systems.

SuperBus® 2000 Phone Interface/Voice Module

Troubleshooting Troubleshooting Table 3: PIV Troubleshooting Problem Action/Solution The module status LED stays off. 1. Check for incorrect wiring connections. 2. Make sure the panel AC power transformer is plugged in and the backup battery is connected. 3. Verify that the panel recog- nizes the module and is enrolled in the correct parti- tion by entering program mode (see panel Installa- tion Instructions). 4. If the LED still remains off, replace the module. The module status LED stays lit but doesn’t flash. 1. Verify that the panel recog- nizes the module and is enrolled in the correct parti- tion by entering program mode (see panel Installa- tion Instructions). 2. Check for incorrect wiring connections. 3. If the LED still doesn’t flash, replace the module. The module has random, inconsistent behavior. 1. Check for incorrect wiring connections. 2. Verify that the panel recog- nizes the module and is enrolled in the correct parti- tion by entering program mode (see panel Installa- tion Instructions). Table 4: Phone Troubleshooting Problem Action/Solution Loss of dial tone at on-site phones after wiring RJ-31X jack or connecting the DB-8 cord. 1. Wait 2 minutes and try again. The panel may be busy trying to report to the central station. 2. Disconnect the panel DB-8 cord from the RJ-31X jack. If the phone still doesn’t work the system is okay and the problem is in the phone wiring. 3. Check RJ-31X jack wiring and TELCO block wiring. Replace RJ-31X jack if nec- essary. 4. Check DB-8 cord connec- tions at the panel and RJ- 31X jack. Replace cord if necessary. Constant dial tone, preventing dial-out on premises phones. 1. One or more polarity-sensi- tive phones exist on-site. Reverse the phone wires connected to the brown and gray wire terminals on the RJ-31X jack. Table 5: Speaker Troubleshooting Problem Action/Solution Speakers don’t make any sounds. 1. Make sure the speaker is wired correctly. 2. Ensure that the PIV is working correctly. 3. Verify the module is enrolled into the correct partition by entering pro- gram mode (see panel Installation Instructions). 4. Replace the speaker. Speakers sound status messages but don’t sound alarms. 1. Alarm is in partition 2 and speaker is connected to panel terminals 7 and 8, which activate only for par- tition 1 alarms. 2. Make sure the speaker is wired correctly. 3. Ensure that the PIV is working correctly. 4. Speaker output may have shut down because panel detected terminal 7 or 8 is shorted to ground. Discon- nect panel AC and battery backup power. Locate short and correct. Apply panel AC and backup battery power and try again. Speakers annunciate in/for the wrong partition. 1. Verify the module is enrolled into the correct partition by entering pro- gram mode (see panel Installation Instructions). Table 4: Phone Troubleshooting (Cont.) Problem Action/Solution

SuperBus® 2000 Phone Interface/Voice Module

Specifications Specifications Compatibility: Concord panels Power Requirements: 12 VDC nominal (10V minimum), 600 mA maximum draw from panel Storage Temperature: -30° to 140° F (-34° to 60° C) Operating Temperature:32° to 140° F (0° to 60° C) Humidity: 90% relative humidity, non-condensing Dimensions: 5.5" x 8.0" x 1.5" (H x W x D) Listings: UL 985 Household Fire Warning System Units UL 1023 Household Burglar-Alarm System Units Note See specific panel Installation Instructions for complete UL installation requirements for the system you are installing. Notices FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a resi- dential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: K Reorient or relocate the receiving antenna. K Increase the separation between the equipment and receiver. K Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits. K Consult the dealer or an experienced radio/TV technician for help. FCC Part 68 This equipment complies with part 68 of the FCC Rules. Located on this equipment is a label that contains, among other information, the FCC reg- istration number and the ringer equivalence number (REN) for this equip- ment. If requested, this information must be provided to the telephone company. The REN is used to determine the maximum number of devices that may be connected to your telephone line. In most areas, the sum of all device RENs should not exceed five (5.0). REN for this device: 0.4 If this equipment causes harm to the telephone network, the telephone company may temporarily disconnect your service. If possible, you will be notified in advance. When advance notice is not practical, you will be noti- fied as soon as possible. You will also be advised of your right to file a complaint with the FCC. Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the proper operation of your equipment. You will be given advance notice in order to maintain uninter- rupted service. If you experience trouble with this equipment, please contact the company that installed the equipment for service and repair information. The tele- phone company may ask you to disconnect this equipment from the net- work until the problem has been corrected or you are sure that the equipment is not malfunctioning. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. Security Automation Fire Protection Access Control www.ititechnologies.com T: 651/777-2690 F: 651/779-4890 Interactive Technologies, Inc. 2266 Second Street North North Saint Paul, MN 55109-2900 1-800-777-1415 ©2000 Interactive Technologies, Inc. an Interlogix™ company. Interlogix is a trademark of Interlogix, Inc. ITI and SuperBus are registered trademarks of Interactive Technologies, Inc. Concord is a trademark of Interactive Technologies, Inc.