GSS GLC 100 Assembly Instructions Manual

File Specifications

Brand: GSS
Category: Modem
Model: GLC 100 (Assembly Instructions Manual), prADwAh0O7Dzg
File Type: PDF
File Size: —
Pages: 32 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (32 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 28/03/2026).

Read Online

Read the GSS GLC 100 Assembly Instructions Manual online using the built-in PDF viewer.

Key Pages of Document

Grundig SAT Systems GmbH

Beuthener Strasse 43 D-90471 Nuremberg Phone: +49 (0) 911 / 703 8877 Fax: +49 (0) 911 / 703 9210 E-mail: [email protected] Internet: http://www.gss.de/en GLC 100 Ethernet over Coax ...

- 2 -

GLC 100 Contents 1 Safety regulations and notes ........................................................................4 2 General information ....................................................................................6 2.1 Packing contents ............................................................................6 2.2 Meaning of the symbols used ..........................................................6 2.3 Technical data .............. ...

- 3 -

GLC 100 Private EoC network with encryption: .............................................20 Connect the first two devices: ...................................................20 Integrate further devices: .........................................................21 7 Configuration Software ..............................................................................22 7.1 Installation .................................................................. ...

- 4 -

GLC 100 1 safety regulations and notes +40 +5 0 10 cm 5 cm 5 cm ATTENTION: IN ORDER TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN THE CABINET. INSIDE THE CABINET THERE ARE NO PART WHICH CAN BE REPAIRED BY THE USER. IF NECESSARY CONTACT QUALI- FIED SERVICE TECHNICIANS. Safety precautions: This device was manufactured according to the specifications of international safety standards. For your own protection, you should read the safety instruc- ti ...

- 5 -

GLC 100 • The device should be operated at temperatures of 0 ºC to 40 ºC. Use the device only in a moderate climate, not in tropical conditions. • Avoid short circuits! • Thunderstorms are a danger to all electrical devices. Even if the device is switched off, it can be damaged by a stroke of lightning to the mains or the antenna cable. Therefore always disconnect the device from the mains and from the antenna unit during a thunderstorm or ex ...

- 6 -

GLC 100 2 general information 2.1 PaCking Contents GLC 100 Power supply cable Network cable Termination resistor Brief assembly instructions 2.2 meaning of the symbols used Important note —> General note • Performing works 2.3 teChniCal data The devices meet the following EU directives: 2006/95/EC, 2004/108/EC and 2011/65/EU The product fulfils the guidelines and standards for CE labelling (Page 31). Unless otherwise noted all values are specifie ...

- 7 -

GLC 100 Connectors (LAN) ..................................................................... 2 x RJ 45 LEDs .............................................................Power /EoC /LAN 1/LAN 2 Switching Power supply ..........................................110-230 V~50/60 Hz Power consumption ...............................................................max. 5.5 W Dimensions (WxHxD) in mm ........................................... 145 x 33 x 82, ...

- 8 -

GLC 100 The EoC modems communicate in peer to peer mode (P2P). In the factory default settings, each EoC modem can communicate with each other modem in the network. The advantage of "Ethernet over Coax" is that it is not necessary to lay new network cables and that there is no expenditure for additional installation. The data is transmitted through the low-attenuation return channel, frequency range of 2…68 MHz. Depending on the quality of the coax ...

- 9 -

GLC 100 4 over view of gCl 100 Power OFF ON LAN2 EoC TV Reset Security LAN1 110-230V~ 50-60Hz 7 8 9 0 ! @ 1 2 3 4 5 6 1 Power LED 2 Power switch (ON/OFF) 3 EoC LED 4 LAN1 LED 5 LAN2 LED 6 LAN2 socket 7 EoC socket 8 TV socket 9 Reset button 0 Security button ! LAN1 socket @ Socket for mains cable ...

- 10 -

GLC 100 5 installation and Commissioning 5.1 define the aPProaCh Dependent on the local conditions, several approaches are possible. In order to avoid unnecessary movements, before installation you should de- fine how you want to configure the EoC network. If the antenna system is also used by other participants, you can build up your own private EoC network. By securing your EoC network, you protect all information sent via the network against inad ...

- 11 -

GLC 100 5.2 installation All components of the coaxial distributor structure must support the return chan- nel frequency range of 2…68 MHz. In the simplest case, you establish a connection via two EoC modems (see description page 7). • Connect up to two network devices (e.g. router, PC, smart TV etc.) to the LAN sockets 6/! of one EoC modem. • Connect the "EoC" F socket 7 to the already existing antenna distribution network. Dependant on the l ...

- 12 -

GLC 100 5.3 aPPliCation examPles sat if distribution via multiswitCh feed in via return Channel CaPable antenna soCket The feed in of the IP signals e.g. is done via a return channel capable antenna socket. Router Receiver Receiver Receiver Receiver QRS13DC QRS13DC TV TV TV TV QRS13DC QRS13DC Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 When feeding in IP data via the antenna socket, the terrestrial input of a SAT ...

- 13 -

GLC 100 feed in via the inPut of the sat multiswitCh The feed in of the IP signals e.g. is done via the return channel capable ter- restrial input of the SAT multiswitch. Router Receiver Receiver Receiver Receiver QRS13DC SR 203 QRS13DC TV TV TV TV QRS13DC QRS13DC Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 If the IP data and the DVB-T, FM or CATV signal are fed in using the terrestrial input, ...

- 14 -

GLC 100 head-end station feed in via return Channel CaPable antenna soCket The feed in of the IP signals e.g. is done via a return channel capable antenna socket. Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Router HbbTV + DVB-C/T HbbTV + DVB-C/T HbbTV + DVB-C/T HbbTV + DVB-C/T OR… OR… OR… OR… A commercially available high-pass filter , which blocks the return channel range, must be inserted in the coaxial ...

- 15 -

GLC 100 feed in at the outPut of the head-end station The feed in of the IP signals e.g. is done via a two-way splitter (e.g. SR 203) operated in reverse direction at the output of the head-end station. Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 IPTV + DVB-C/T IPTV + DVB-C/T IPTV + DVB-C/T IPTV + DVB-C/T Router Power EoC LAN1 LAN2 SR 203 OR… OR… OR… OR… A commercially available high-pass filter , which bl ...

- 16 -

GLC 100 broadband Cable feed in via return Channel CaPable antenna soCket The feed in of the IP signals e.g. is done via the return channel capable an- tenna socket. Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Router HbbTV + DVB-C HbbTV + DVB-C HbbTV + DVB-C HbbTV + DVB-C POI The EoC transmission is done in the return channel frequency range of 2…68 MHz, which is also used for Internet services in broadband net ...

- 17 -

GLC 100 feed in at the outPut of the broadband Cable modem The feed in of the IP signals e.g. is done via a two-way splitter (e.g. SR 203) operated in reverse direction at the output of the broadband cable modem. Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Power EoC LAN1 LAN2 Cable Router HbbTV + DVB-C HbbTV + DVB-C HbbTV + DVB-C HbbTV + DVB-C SR 203 CTV EoC LAN POI The EoC transmission is done in the return chan ...

- 18 -

GLC 100 5.4 Commissioning As soon as all connections have been established, the EoC devices can be switched on by pressing the power switches 2 and the connected devices (PC, notebook etc.) can be booted up. indiCators Power-led The Power LED 1 flashes for a short time and lights continuously as soon as the device is ready for operation. It flashes in standby mode (page 19). eoC-led The EoC LED 3 light up green as soon as a connection to an other de ...

- 19 -

GLC 100 standby mode After some minutes without data transfer, an EoC modem switches into stand- by mode. The Power LED flashes. —> The standby mode is automatically terminated as soon as a connect- ed device starts a data communication, or if the modem is switched off and on again. —> During standby mode the reset button and the security button are out of order. faCtory defaults Using the Reset button 9 the EoC modem can be reset to the factory ...

- 20 -

GLC 100 6 Configuration An EoC network consists of two or more (max. 64) EoC modems using the same network key. In an existing antenna system with several participants, all devices can con- nect to each other (factory default). 6.1 seCurity funCtion If the antenna system is also used by other participants, you can build up your own private EoC network. By securing your EoC network, you protect all information sent via the network against inadvertent ...