EN - 1
Contents: 1 SAFETY PRECAUTIONS AND PROCEDURES .......................................................... 2 1.1 Preliminary ...................................................................................................................... 2 1.2 Before use ....................................................................................................................... 3 1.3 After use .......................................................................................................................... 3 1.4 Measuring (overvoltage) categories definitions ............... ...
EN - 14
6 TECHNICAL SPECIFICATIONS 6.1 CHARACTERISTICS Accuracy is calculated as [% rdg + (n°of dgt) * resolution] referred to: 23°C ± 5°C <80%RH DC Voltage Range Resolution Accuracy Input impedance Overload protection 200.0mV 0.1mV (1.0%rdg + 3dgt) 10M 1000VDC/ACrms 2.000V 0.001V 20.00V 0.01V 200.0V 0.1V 1000V 1V The meter emits a continuous sound with VDC >1000V AC Voltage Range Resolution Accuracy (50 60Hz) Input impedance Overload protection 200.0mV 0.1mV (1.5%rdg + 15dgt) 10M 1000VDC/ACrms 2.000V 0.001V (1.0%rdg + 4dgt) 20.00V 0.01V 200.0V 0.1V 1000V 1V Integrated sensor for A ...
EN - 3
1.2 BEFORE USE Always keep to the instructions contained in this manual: CAUTION Non compliance with the warnings and/or the instructions may damage the tester and/or its components or injure the operator. Before changing the switch’s position, take off the clamp jaw from the tested conductor or the electrical circuit in order to avoid any accident When the clamp is connected to the circuits to be tested, never touch unused terminals When testing resistors, do not add voltage. Although there is a protection circuit, excessive voltage would cause malfunctioning Before measur ...
EN - 14
6 TECHNICAL SPECIFICATIONS 6.1 CHARACTERISTICS Accuracy is calculated as [% rdg + (n°of dgt) * resolution] referred to: 23°C ± 5°C <80%RH DC Voltage Range Resolution Accuracy Input impedance Overload protection 200.0mV 0.1mV (1.0%rdg + 3dgt) 10M 1000VDC/ACrms 2.000V 0.001V 20.00V 0.01V 200.0V 0.1V 1000V 1V The meter emits a continuous sound with VDC >1000V AC Voltage Range Resolution Accuracy (50 60Hz) Input impedance Overload protection 200.0mV 0.1mV (1.5%rdg + 15dgt) 10M 1000VDC/ACrms 2.000V 0.001V (1.0%rdg + 4dgt) 20.00V 0.01V 200.0V 0.1V 1000V 1V Integrated sensor for A ...
HT HT9012 user guide recommended for: C2006, D40, HT20, IRONMETER, T2000.
⚠️ Download Safety
The Measuring Instruments Operation & user’s manual (17 pages) is completely safe to download (last scan date: 17/02/2026).
Related PDF Instructions for HT HT9012:
-
HT THT32 Thermal cameras Operation & user’s manual
THT3221 -
HT HT25N Multimeter Operation & user’s manual
HT25N16 -
HT HT32 Multimeter Operation & user’s manual
HT3223 -
HT HT4013 Measuring Instruments Operation & user’s manual
HT401321 -
HT HT77N Multimeter Operation & user’s manual
HT77N14 -
HT HT77N Measuring Instruments Operation & user’s manual
HT77N60
Measuring Instruments Equipment: Frequently Requested
-
WP Measuring Instruments
06.02.2026Instruction reference guide for the HYDROMETER WP Measuring Instruments. The guide describes usage and backup procedures, service instructions, technical assistance, maintenance schedule.WP, 4 pages -
CONTOIL VZF II Measuring Instruments
01.10.2025Instructions for safe usage of the Aquametro CONTOIL VZF II Measuring Instruments. It outlines maintenance guidelines and startup procedures, internal layout, configuration options.CONTOIL VZF II, 48 pages -
Spirobank II Medical Equipment
22.10.2025Advanced user guide for the MIR Spirobank II Medical Equipment. This documentation outlines operational safety, usage tips, supported accessories.Spirobank II, 57 pages -
ZKJ Series Measuring Instruments
11.10.2025User instruction booklet for the Fuji Electric ZKJ Series Measuring Instruments. It details troubleshooting tips and service procedures, troubleshooting guides, testing procedures.ZKJ Series, 106 pages -
TN400 Measuring Instruments
16.10.2025Installation and maintenance guide for the Apera Instruments TN400 Measuring Instruments. The manual provides information on installation guides, operating instructions, hardware setup, device overview.TN400, 14 pages -
MX4A Measuring Instruments
06.12.2025Device setup guide for the TELEVAC MX4A Measuring Instruments. The manual outlines system configuration and safety precautions, operational safety, hardware components.MX4A, 17 pages
Have some Questions about HT HT9012 Device?
Get valuable and actionable advices from other HT HT9012 device users. Describe your problem or question, regarding the using of HT HT9012, in as much detail as possible, and other users will be able to answer you.