HT HT9012 Operation & User’s Manual

File Specifications

Brand: HT
Category: Measuring Instruments
Model: HT9012 (Operation & User’s Manual), prnHrWoNGrqH2
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 17 pages

Download PDF

Download HT HT9012 Manual (17 pages)

Read Online:

Read the HT HT9012 Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

EN - 1

Contents: 1 SAFETY PRECAUTIONS AND PROCEDURES .......................................................... 2 1.1 Preliminary ...................................................................................................................... 2 1.2 Before use ....................................................................................................................... 3 1.3 After use .......................................................................................................................... 3 1.4 Measuring (overvoltage) categories definitions ............... ...

EN - 14

6 TECHNICAL SPECIFICATIONS 6.1 CHARACTERISTICS Accuracy is calculated as [% rdg + (n°of dgt) * resolution] referred to: 23°C ± 5°C <80%RH DC Voltage Range Resolution Accuracy Input impedance Overload protection 200.0mV 0.1mV (1.0%rdg + 3dgt) 10M 1000VDC/ACrms 2.000V 0.001V 20.00V 0.01V 200.0V 0.1V 1000V 1V The meter emits a continuous sound with VDC >1000V AC Voltage Range Resolution Accuracy (50 60Hz) Input impedance Overload protection 200.0mV 0.1mV (1.5%rdg + 15dgt) 10M 1000VDC/ACrms 2.000V 0.001V (1.0%rdg + 4dgt) 20.00V 0.01V 200.0V 0.1V 1000V 1V Integrated sensor for A ...

EN - 3

1.2 BEFORE USE Always keep to the instructions contained in this manual: CAUTION Non compliance with the warnings and/or the instructions may damage the tester and/or its components or injure the operator. Before changing the switch’s position, take off the clamp jaw from the tested conductor or the electrical circuit in order to avoid any accident When the clamp is connected to the circuits to be tested, never touch unused terminals When testing resistors, do not add voltage. Although there is a protection circuit, excessive voltage would cause malfunctioning Before measur ...

EN - 14

6 TECHNICAL SPECIFICATIONS 6.1 CHARACTERISTICS Accuracy is calculated as [% rdg + (n°of dgt) * resolution] referred to: 23°C ± 5°C <80%RH DC Voltage Range Resolution Accuracy Input impedance Overload protection 200.0mV 0.1mV (1.0%rdg + 3dgt) 10M 1000VDC/ACrms 2.000V 0.001V 20.00V 0.01V 200.0V 0.1V 1000V 1V The meter emits a continuous sound with VDC >1000V AC Voltage Range Resolution Accuracy (50 60Hz) Input impedance Overload protection 200.0mV 0.1mV (1.5%rdg + 15dgt) 10M 1000VDC/ACrms 2.000V 0.001V (1.0%rdg + 4dgt) 20.00V 0.01V 200.0V 0.1V 1000V 1V Integrated sensor for A ...

HT HT9012 user guide recommended for: C2006, D40, HT20, IRONMETER, T2000.

⚠️ Download Safety

The Measuring Instruments Operation & user’s manual (17 pages) is completely safe to download (last scan date: 17/02/2026).

Related PDF Instructions for HT HT9012:

Measuring Instruments Equipment: Frequently Requested

Have some Questions about HT HT9012 Device?

Get valuable and actionable advices from other HT HT9012 device users. Describe your problem or question, regarding the using of HT HT9012, in as much detail as possible, and other users will be able to answer you.