Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference. This appliance is suitable for installation in a bedroom or bed sitting room. ESPRIT INSTALLATION AND OPERATING INSTRUCTIONS Visit www. pacificenergy.net for the most recent version of this manual MODEL: ESPR.BODYB ESPRIT ZERO CLEARANCE FIREPLACE WARNING: If the information in these instruc- tions is not followed exactly a fire or explosion may result ca ...

Table of Contents

Important Note for the Commonwealth of Massachusetts ......................... 3 Caution ....................................................................4 Safety ......................................................................5 First Fire .................................................................. 6 Remote Control Operation ......................................7 System Description ............................. ...

Important Note for the Commonwealth of Massachusetts

From Massachusetts Rules and Regulations 248 CMR 5.08: (a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, includ ...

This fireplace is equipped with a micro mesh safety screen for your protection and

must be installed with the unit. Removal of the safety screen will cause the fireplace to become a burn and fire hazard. FOR YOUR SAFETY - Do not install or operate your Pacific Energy fireplace without first reading and understanding this manual. Any installation or operational deviation from the following instruc- tions voids the Pacific Energy Warranty and may p ...

Due to high temperatures, this gas appliance should be located out of traffic and away from

furniture and draperies. •� Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. •� Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact b ...

Congratulations on your purchase of a Pacific Energy Gas Appliance.

Your fireplace has been professionally installed by: Dealer name: ___________________________________________________ Phone Number:___________________________________________________ If you discover any problems with your gas appliance contact your dealer immediately to have the unit repaired. Caution: Do not attempt to repair the fireplace because you may cause injury to yourself or oth ...

Blue back lit LCD display

ON/OFF Key THERMOSTAT Key UP/DOWN Arrow Key MODE Key Figure 1: Proflame 2 handset. OFF ON SMART MAX KEY LOCK LOW BATTERY ALARM ROOM TEMPERATURE CPI MODE FLAME LEVEL SET POINT: TEMPERATURE/LEVEL/STATE THERMOSTAT OFF/ ON/SMART TRANSMISSION COMFORT FAN Figure 2: Proflame 2 LCD display. System Description The Proflame 2 Remote Control System consists of two elements: 1. Proflame2 Transmitter. 2. Proflame2 Integrated Fireplace Control ...

The Proflame 2 Integrated Fireplace Control (IFC) module (Figure 3) is a device that allows automatic

ignition and pilot flame supervision, and commands the functions of the hearth Fireplace. It’s configured to control the ON/OFF main burner operation, giving the choice of both IPI (intermittent pilot ignition), and CPI (continuous pilot ignition) modes. The Proflame2 IFC module controls and connects directly to the pilot assembly and the aut ...

Temperature indication Display

With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of the Room Temperature display (Figure 6 or Figure 7). Turn on the Fireplace With the system OFF, press the ON/OFF Key on the remote transmitter. The remote transmitter display will show some other active Icons on the screen. At the ...

Remote Flame Control

The Proflame2 has six (6) flame levels. With the system turned on, and the flame level at maximum in the Fireplace, press the down arrow key once to reduce the flame height by one step until the flame is turned off. The up arrow key will increase the flame height each time it is pressed. If the up arrow key is pressed while the system is on but the flame is off, the flame will come on in the high position (Figure 9). A single ...

Figure 13: Comfort fan control.

Figure 14: IPI CPI Selection. Comfort Fan Speed Control If the fireplace is equipped with a hot air circulating fan, the speed of the fan can be controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds. To activate this function use the Mode Key (Fig.1) to index to the fan control icon (Fig. 13 ). Use the Up/Down Arrow Keys (Fig.1) to turn on, off or adjust the fan speed (Fig. 13). A single � ...

Figure 15: Low battery

icon. WARNING Fire Hazard. Can cause severe injury or death The Receiver causes ignition of the appliance. The appliance can turn on suddenly. Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system. WARNING Shock Hazard. Can cause severe injury or death This device is powered by line voltage. Do not try to repair this device. In no way is the enclosure to be tampered wit ...

Figure 17: Esprit pilot assembly.ai

Maintenance Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the fireplace and its venting should be inspected at least once a year by a qualified service person. Glass Door: Warning: Do not operate fireplace with glass door removed, cracked or broken. Replacement of the glass door should be done by a licensed ...

Figure 18: Esprit dimensions.

48” 1219 mm 24” 610 mm 33 5/8” 854 mm 1 1/8” (29 mm) Minimum Non-combustible Combustible 19 1/2” 495 mm Figure 19: Framing and finishing dimensions. Fireplace Dimensions The installation must conform with local codes or, in the absence of local codes, with the National Fuel ...

Figure 20: Framing at the corner.

Figure 21: Minimum clearance corner framing. 16 5056.201-A ESPRIT 280617-40 ...

Top of glass

(Reference point) Figure 22: Minimum distance from top of the glass to ceiling. 36” Min. Figure 23: Front and side dimensions. Clearances to Combustibles Minimum Clearance to Combustible Materials ENCLOSED SIDE WALL 1.75” ENCLOSED BACK WALL NCR* ENCLOSED CEILING 4” ECLOSED FRONT WALL 24” From top of the glass EXPOSED SIDE WALL 8” From side of the glass VENT ENCLOSU ...

Figure 24: Common installation options.

33 5/8” 854mm 45” 1143mm Figure 25: Framing dimensions. Locating the Fireplace In planning the installation for the fireplace, it is necessary to determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed. Various installations are possible, such as, into an existing wall, a corner, a built in wall or a wall projection. Due to high temperatures, do not locate ...

Figure 26: Louvered surround.

Surround base Faceplate Screen with frame Figure 27: Clean face surround. Surround Installation Instructions Installation 1. Fasten the surround base to the fireplace using supplied screws and mounting holes located along the inner edge of the base. 2. Install screen with the frame in slots on inner side of the surround base. 3. Install the surround front by positioning it so as t ...