NX-148E-RF LCD Touchpad with Receiver Installation Instructions Content Contact information 1 Product summary 1 Installation 2 Transmitter programming 2 Touchpad programming 5 Reference tables 9 Specifications 14 Regulatory information 14 Contact information www.utcfireandsecurity.com or www.interlogix.com For ...
Installation To install the touchpad, do the following: 1. Remove the mounting-plate screw (Figure 1) from the bottom of the touchpad and lift off the mounting plate. Caution: You must be free of static electricity before handling circuit boards. Wear a grounding strap of touch a bare metal s ...
3 RM: receiver module HE: hardwire expander P: panel This gives you all the programming information in one place and facilitates the programming process. Zone locations 401 to 592 Zone locations 401 to 592 are not numbered in Table 11 since these locations vary depending on location 594, Receiv ...
9. To program remaining transmitters, repeat steps 6 to 8. 10. To exit program mode, press EXIT EXIT. Transmitter options Door/window transmitter settings To set features 4 (Input option 1) and 5 (Input option 2) for door/window transmitters, do the following: • To disable the transmitter� ...
5 4. Enter the zone location and press #. For example, enter 407 # to delete zone 7. 5. To change transmitter feature 1 (Transmitter enabled), enter 1 and press *. The 1 turns off to indicate the feature change. 6. To delete additional transmitters, repeat steps 3 to 5. Note: To delete all tran ...
Service menu (2) A Service Required message will display periodically if the system requires service. To access the service menu, do the following: 1. Enter * 2 to display one or more of the fault messages in Table 9. 2. Press or to scroll through the messages. 3. To exit the service messag ...
7 Assign user authority (6) To assign user authority levels, you must have authority over the assigned partitions. To assign user authority, do the following: 1. Enter * 6. 2. Enter your master code. 3. Enter the user number. 4. Use keys 1 (yes) and 0 (no) to assign authorities when prompted, o ...
Table 7. Editing character data Command Action * Saves character or word. Moves cursor to the right. CANCEL Moves cursor to the left. Scrolls through available characters. In library mode, scrolls through available w ords. STAY Inserts a black space. CHIME Deletes characters. EXIT Accesses th ...
9 Silent exit (EXIT) To silence the exit beeps during exit delay (while the system is disarmed), do the following: 1. Enter * EXIT. 2. Enter your user code. 3. To exit, press #. Reference tables Table 9. Service menu messages Message Explanation Control over current A short circuit of a pow er ...
Man Test Manual test - Bell and/or communicator test w hile system is disarmed. Re-exit The exit delay has been restarted w ithout disarming the system. Output Trip A trip has occurred on an expander auxiliary output. Data Lost Communication of a signal has failed (log only event). Walk-test ...
⚠️ Download Safety
The Keypad Installation instructions manual (14 pages) is completely safe to download (last scan date: 18/07/2026).
Related PDF Instructions for Interlogix NX-148E-RF:
-
Interlogix UltraView UVD-6130VE-2 Series Security Camera Operation & user’s manual, 20 pages
-
Interlogix TVC-5125BE-3 Digital Camera Pocket manual, 8 pages
-
Interlogix advisorone Security System Quick installation manual, 18 pages
-
Interlogix ATS1741 RS232 Recording Equipment Installation sheet, 16 pages
-
Interlogix NS3562-8P-2S Switch Operation & user’s manual, 245 pages
-
Interlogix RF-1110-07-1 Kitchen Appliances Installation sheet, 3 pages