Innominate mGuard Reference Manual
Text of the manual
Hardware Reference Manual
Innominate
Security Technologies
Configuration of the mGuard Security Appliances
Innominate Security Technologies
I15007_en_02
Installing and starting up the mGuard hardware
UM EN MGUARD DEVICES
02
—
This user manual is valid for the following devices of the mGuard product range:
–
mGuard
rs4000/rs2000
–
rs4000 TX/TX
–
rs4000 TX/TX VPN
–
rs2000 TX/TX VPN
–
mGuard
rs4000/rs2000 Switch
–
rs4000 4TX/TX
–
rs4000 4TX/TX VPN
–
rs2000 5TX/TX VPN
–
mGuard
rs4000/rs2000
3G
–
rs4000 4TX/3G/TX VPN
–
rs2000 4TX/3G VPN
–
mGuard
smart²/smart
–
mGuard
pci²
SD
–
mGuard pcie² SD
–
mGuard
pci
–
mGuard
blade
–
mGuard
delta²
–
mGuard
delta
–
mGuard
centerport²
–
mGuard
centerport
–
mGuard
industrial
rs
–
EAGLE
mGuard
User manual
Designation:
Revision:
Order No.:
Innominate Security Technologies
Please observe the following notes
Target group of this user manual
The use of products described in this manual is aimed exclusively at qualified electricians
or persons instructed by them, who are familiar with applicable national standards and other
regulations regarding electrical engineering and, in particular, the relevant safety concepts.
Explanation of symbols used and signal words
General terms and conditions of use for technical documentation
Innominate reserves the right to alter, correct, and/or improve the technical documentation
and the products described in the technical documentation at its own discretion and without
giving prior notice, insofar as this is reasonable for the user. The same applies to any
changes that serve the purpose of technical progress.
The receipt of technical documentation (in particular user documentation) does not consti-
tute any further duty on the part of Innominate to furnish information on modifications to
products and/or technical documentation. You are responsible for verifying the suitability
and intended use of the products in your specific application, in particular with regard to ob-
serving the applicable standards and regulations. All information made available in the tech-
nical data is supplied without any accompanying guarantee, whether expressly mentioned,
implied or tacitly assumed.
In general, the provisions of the current standard Terms and Conditions of Innominate apply
exclusively, in particular as concerns any warranty liability.
This user manual, including all illustrations contained herein, is copyright protected. Any
changes to the contents or the publication of extracts of this document are prohibited.
Innominate reserves the right to register its own intellectual property rights for the product
identifications of Innominate products that are used here. Registration of such intellectual
property rights by third parties is prohibited.
Other product identifications may be afforded legal protection, even where they may not be
indicated as such.
This symbol indicates hazards that could lead to personal injury. Obey all safety
measures that follow this symbol to avoid possible injury or death.
There are three different categories of personal injury that are indicated by a sig-
nal word.
DANGER
This indicates a hazardous situation which, if not avoided, will re-
sult in death or serious injury.
WARNING
This indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
This indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
This symbol together with the signal word NOTE and the accompanying text
alert the reader to a situation which may cause damage or malfunction to the de-
vice, hardware/software, or surrounding property.
This symbol and the accompanying text provide the reader with additional infor-
mation or refer to detailed sources of information.
Innominate Security Technologies
“Innominate” and “mGuard” are registered trade names of Innominate Security Technolo-
gies AG. mGuard technology is protected by patents 10138865 and 10305413, granted by
the German Patent and Trademark Office. Further patents are pending.
Published by
Innominate Security Technologies AG
Rudower Chaussee 13
12489 Berlin
Germany
Phone: +49 (0)30 92 10 28-0
[email protected]
www.innominate.com
© 24. July 2015 Innominate Security Technologies AG
Notes on CE identification
The declarations of conformity are held here in agreement with EU directives for the relevant
authorities:
Innominate Security Technologies AG
Rudower Chaussee 13
12489 Berlin
Germany
Tel. +49 (0)30 92 10 28-0
Innominate Security Technologies
FCC Note
The FCC Statement applies to the following devices:
Class A: mGuard
rs4000, mGuard
rs2000, mGuard
rs4000
Switch,
mGuard
rs2000
Switch, mGuard
centerport, mGuard
industrial
rs, mGuard
smart²,
mGuard
smart, mGuard
pci, mGuard
pci²
SD, mGuard
delta, mGuard
delta², and
EAGLE
mGuard. Class B: mGuard
rs4000
3G, mGuard
rs2000
3G, mGuard
centerport²
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired opera-
tion.
Class A
Class B
This equipment has been
tested and found to comply
with the limits for a Class A
digital device, persuant to
part 15 of the FCC Rules.
These limits are designed to
provide reasonable protec-
tion against harmful interfer-
ence when the equipment is
operated in a commercial
environment. This equip-
ment generates, uses, and
can radiate radio frequency
energy and, if not installed
and used in accordance with
the instruction manual, may
cause harmful interference
to radio communications.
Operation of this equipment
in a residential area is likely
to cause harmful interfer-
ence in which case the user
will be required to correct the
interference at his own ex-
pense.
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interfer-
ence in a residential installation. This equipment gener-
ates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio commu-
nications. However, there is no guarantee that interfer-
ence will not occur in a particular installation. If this
equipment does cause harmful interference to radio or
television reception, which can be determined by turn-
ing the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the fol-
lowing measures:
–
Reorient or relocate the receiving antenna.
–
Increase the separation between the equipment
and receiver.
–
Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
–
Consult the dealer or an experienced radio/TV
technician for help.
Changes or modifications not expressly approved by
the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC RF radiation Exposure Statement: This equip-
ment complies with FCC RF exposure limits set forth for
an uncontrolled environment. The antenna(s) used for
this transmitter must be installed and operated with a
minimum separation distance of 20 cm from all persons
and must not be co-located or operating in conjunction
with any other antenna or transmitter expect in accor-
dance with the FCC multi-transmitter policy.
Innominate Security Technologies
7
Table of contents
1
mGuard
rs4000/rs2000 ............................................................................................................11
1.1
Operating elements and LEDs.............................................................................12
1.2
Startup.................................................................................................................14
1.3
Installation of mGuard
rs4000/rs2000..................................................................15
1.4
Preparing the configuration..................................................................................20
1.5
Configuration in Stealth mode..............................................................................21
1.6
Establishing a local configuration connection ......................................................24
1.7
Remote configuration ..........................................................................................26
1.8
Restart, recovery procedure, and flashing the firmware.......................................27
1.9
Technical data .....................................................................................................31
2
mGuard
rs4000/rs2000 Switch ................................................................................................33
2.1
Operating elements and LEDs.............................................................................34
2.2
Startup.................................................................................................................36
2.3
Installing the mGuard
rs4000/rs2000 Switch .......................................................37
2.4
Preparing the configuration..................................................................................42
2.5
Configuration in Router mode..............................................................................42
2.6
Establishing a local configuration connection ......................................................43
2.7
Remote configuration ..........................................................................................45
2.8
Restart, recovery procedure, and flashing the firmware.......................................46
2.9
Technical data .....................................................................................................50
3
mGuard
rs4000/rs2000
3G ......................................................................................................51
3.1
Operating elements and LEDs.............................................................................52
3.2
Startup.................................................................................................................54
3.3
Installation of mGuard
rs4000/rs2000
3G ............................................................55
3.4
Preparing the configuration..................................................................................64
3.5
Configuration in Router mode..............................................................................64
3.6
Establishing a local configuration connection ......................................................65
3.7
Remote configuration ..........................................................................................67
3.8
Restart, recovery procedure, and flashing the firmware.......................................68
3.9
Technical data .....................................................................................................72
4
mGuard
delta² ..........................................................................................................................75
4.1
Operating elements and LEDs.............................................................................76
4.2
Startup.................................................................................................................77
4.3
Connecting the mGuard
delta² ............................................................................78
4.4
Preparing the configuration..................................................................................79
4.5
Configuration in Stealth mode..............................................................................80
4.6
Establishing a local configuration connection ......................................................83
4.7
Remote configuration ..........................................................................................85
4.8
Restart, recovery procedure, and flashing the firmware.......................................86
Innominate Security Technologies
I15007_en_02
4.9
Technical data .....................................................................................................90
5
mGuard
pci²
SD .......................................................................................................................91
5.1
Operating elements and LEDs.............................................................................92
5.2
Startup.................................................................................................................93
5.3
Installation of mGuard
pci²
SD ............................................................................94
5.4
Preparing the configuration..................................................................................95
5.5
Configuration in Stealth mode..............................................................................96
5.6
Establishing a local configuration connection ....................................................101
5.7
Remote configuration ........................................................................................103
5.8
Restart, recovery procedure, and flashing the firmware.....................................104
5.9
Technical data ...................................................................................................107
6
mGuard
smart²/smart .............................................................................................................109
6.1
Operating elements and LEDs...........................................................................110
6.2
Startup...............................................................................................................111
6.3
Connecting the mGuard
smart² ........................................................................112
6.4
Preparing the configuration................................................................................113
6.5
Configuration in Stealth mode............................................................................114
6.6
Establishing a local configuration connection ....................................................117
6.7
Remote configuration ........................................................................................119
6.8
Restart, recovery procedure, and flashing the firmware.....................................120
6.9
Technical data ...................................................................................................123
7
mGuard
centerport² ...............................................................................................................125
7.1
Operating elements and LEDs...........................................................................126
7.2
Startup...............................................................................................................127
7.3
Installing and booting the mGuard
centerport²...................................................128
7.4
Preparing the configuration................................................................................132
7.5
Establishing a local configuration connection ....................................................133
7.6
Remote configuration ........................................................................................135
7.7
Restart, recovery procedure, and flashing the firmware.....................................136
7.8
Performing a restart ...........................................................................................136
7.9
Technical data ...................................................................................................141
8
mGuard
delta .........................................................................................................................143
8.1
Operating elements and LEDs...........................................................................144
8.2
Startup...............................................................................................................145
8.3
Connecting the mGuard
delta............................................................................146
8.4
Preparing the configuration................................................................................147
8.5
Establishing a local configuration connection ....................................................149
8.6
Remote configuration ........................................................................................151
Table of contents
I15007_en_02
Innominate Security Technologies
9
8.7
Restart, recovery procedure, and flashing the firmware.....................................152
8.8
Technical data ...................................................................................................155
9
mGuard
pci ............................................................................................................................157
9.1
Operating elements and LEDs...........................................................................158
9.2
Startup...............................................................................................................159
9.3
Installation of mGuard
pci .................................................................................160
9.4
Preparing the configuration................................................................................169
9.5
Configuration in Stealth mode............................................................................170
9.6
Establishing a local configuration connection ....................................................172
9.7
Remote configuration ........................................................................................174
9.8
Restart, recovery procedure, and flashing the firmware.....................................175
9.9
Technical data ...................................................................................................179
10
mGuard
blade ........................................................................................................................181
10.1
Operating elements and LEDs...........................................................................182
10.2
Startup...............................................................................................................183
10.3
Installation of mGuard
blade..............................................................................184
10.4
Preparing the configuration................................................................................187
10.5
Establishing a local configuration connection ....................................................189
10.6
Remote configuration ........................................................................................191
10.7
Restart, recovery procedure, and flashing the firmware.....................................192
10.8
Technical data ...................................................................................................195
11
mGuard
centerport .................................................................................................................197
11.1
Operating elements and LEDs...........................................................................198
11.2
Startup...............................................................................................................199
11.3
Installing and booting mGuard
centerport..........................................................200
11.4
Preparing the configuration................................................................................204
11.5
Establishing a local configuration connection ....................................................206
11.6
Remote configuration ........................................................................................208
11.7
Restart, recovery procedure, and flashing the firmware.....................................209
11.8
Performing a restart ...........................................................................................209
11.9
Technical data ...................................................................................................214
12
mGuard
industrial
rs ...............................................................................................................215
12.1
Operating elements and LEDs...........................................................................216
12.2
Startup...............................................................................................................217
12.3
Installation of mGuard
industrial
rs ....................................................................218
12.4
Preparing the configuration................................................................................225
12.5
Configuration in Stealth mode............................................................................226
12.6
Establishing a local configuration connection ....................................................229
Innominate Security Technologies
I15007_en_02
12.7
Remote configuration ........................................................................................231
12.8
Restart, recovery procedure, and flashing the firmware.....................................232
12.9
Technical data ...................................................................................................235
13
EAGLE
mGuard .....................................................................................................................237
13.1
Operating elements and LEDs...........................................................................238
13.2
Startup...............................................................................................................239
13.3
Installation of EAGLE
mGuard ........................................................................240
13.4
Preparing the configuration................................................................................243
13.5
Configuration in Stealth mode............................................................................244
13.6
Establishing a local configuration connection ....................................................247
13.7
Remote configuration ........................................................................................249
13.8
Restart, recovery procedure, and flashing the firmware.....................................250
13.9
Technical data ...................................................................................................253
14
Assigning IP addresses and setting up DHCP/TFTP servers .................................................255
14.1
Assigning the IP address using IPAssign.exe....................................................255
14.2
Installing the DHCP and TFTP server ................................................................258
Innominate Security Technologies
11
1
mGuard
rs4000/rs2000
Table
1-1
Available mGuard
rs4000/rs2000 versions
The mGuard
rs4000 is a security router with intelligent firewall and optional IPsec VPN (10
to 250 tunnels). It has been designed for use in industry to accommodate strict distributed
security and high availability requirements.
The mGuard
rs2000 is a version with basic firewall and integrated IPsec VPN (maximum
of two tunnels). Its scope of functions is reduced to the essentials. It is suitable for secure
remote maintenance applications in industry and enables the quick startup of robust field
devices for industrial use, thereby facilitating error-free, independent operation.
Both versions support a replaceable configuration memory in the form of an SD card. (The
SD cards are not supplied as standard.) The fanless metal housing is mounted on a DIN rail.
The following connectivity options are available
Figure
1-1
mGuard
rs4000/mGuard
rs2000
Available versions
Order No.
mGuard rs4000 TX/TX
HW-107010
mGuard rs4000 TX/TX VPN
BD-701000
mGuard rs2000 TX/TX VPN
HW-108010
mGuard
rs4000: (LAN/WAN)
mGuard
rs2000: (LAN/WAN)
TX/TX
Ethernet/Ethernet
TX/TX VPN
Ethernet/Ethernet + VPN
TX/TX VPN
Ethernet/Ethernet + VPN
Innominate Security Technologies
I15007_en_02
1.1
Operating elements and LEDs
Figure
1-2
Operating elements and LEDs on the mGuard
rs4000
LEDs, see Table
1-2
For plug-in screw terminal
blocks, assignment, refer to
Page
16 and Page
19
Configuration
(SD card)
Connections below:
RS-232 interface
Reset button
Table
1-2
LEDs on the mGuard
rs4000 and mGuard
rs2000
LED
State
Meaning
P1
Green
On
Power supply 1 is active
P2
Green
On
Power supply 2 is active (mGuard
rs2000: not used)
STAT
Green
Flashing
Heartbeat. The device is correctly connected and operating.
ERR
Red
Flashing
System error. Restart the device.
–
Press the Reset button (for 1.5 seconds).
–
Alternatively, briefly disconnect the device power supply and then connect it
again.
If the error is still present, start the recovery procedure (see Page
28) or contact your
dealer.
STAT+ ERR
Flashing alter-
nately: green and
red
Boot process. When the device has just been connected to the power supply. After
a few seconds, this LED changes to the heartbeat state.
SIG
–
(Not used)
FAULT
Red
On
The signal output takes low level due to an error (inverted logic) (see Page
17 or
Page
18). The signal output is inactive during a restart.
MOD
Green
On
Connection via modem established
Innominate Security Technologies
13
INFO
Green
On
Up to firmware version 8.0: the configured VPN connection has been established
As of firmware version 8.1, the configured VPN connections are established or the
firewall rule records defined at output O1 are activated
Flashing
Up to firmware version 8.0: the configured VPN connection is being established or
aborted
As of firmware version 8.1: the configured VPN connections are being established or
aborted or the defined firewall rule records are activated or deactivated.
LAN
Green
On
The LAN/WAN LEDs are located in the LAN/WAN sockets (10/100 and duplex LED)
Ethernet status. Indicates the status of the LAN or WAN port. As soon as the device
is connected to the relevant network, a continuous light indicates that there is a con-
nection to the network partner in the LAN or WAN. When data packets are transmit-
ted, the LED goes out briefly.
WAN
Green
On
Table
1-2
LEDs on the mGuard
rs4000 and mGuard
rs2000 [...]
LED
State
Meaning
Innominate Security Technologies
I15007_en_02
1.2
Startup
1.2.1
Safety notes
To ensure correct operation and the safety of the environment and of personnel, the
mGuard must be installed, operated, and maintained correctly.
General notes regarding usage
1.2.2
Checking the scope of supply
Before startup, check the scope of supply to ensure nothing is missing.
The scope of supply includes:
–
The device
–
Package slip
–
Plug-in screw terminal blocks for the power supply connection and inputs/outputs (in-
serted)
NOTE:
Risk of material damage due to incorrect wiring
Only connect the mGuard network ports to LAN installations. Some telecommunications
connections also use RJ45 sockets; these must not be connected to the RJ45 sockets of
the mGuard.
NOTE:
Select suitable ambient conditions
–
Ambient temperature:
-20°C
...
+60°C
–
Maximum humidity, non-condensing
5%
...
95%
To avoid overheating, do not expose the mGuard to direct sunlight or other heat sources.
NOTE:
Cleaning
Clean the device housing with a soft cloth. Do not use aggressive solvents.
Innominate Security Technologies
15
1.3
Installation of mGuard
rs4000/rs2000
1.3.1
Mounting/removal
Mounting
The device is ready to operate when it is supplied. The recommended sequence for mount-
ing and connection is as follows:
•
Mount the mGuard
rs4000/rs2000 on a grounded 35 mm DIN rail according to
DIN
EN
60715.
Figure
1-3
Mounting the mGuard
rs4000/rs2000 on a DIN rail
•
Attach the top snap-on foot of the mGuard
rs4000/rs2000 to the DIN rail and then press
the mGuard
rs4000/rs2000 down towards the DIN rail until it engages with a click.
Removal
•
Remove or disconnect the connections.
•
To remove the mGuard
rs4000/rs2000 from the DIN rail, insert a screwdriver horizon-
tally in the locking slide under the housing, pull it down – without tilting the screwdriver
– and then pull up the mGuard
rs4000/rs2000.
Innominate Security Technologies
I15007_en_02
1.3.2
Connecting to the network
•
Connect the mGuard to the network. To do this, you need a suitable UTP cable (CAT5)
which is not included in the scope of supply.
•
Connect the internal network interface LAN 1 of the mGuard to the corresponding
Ethernet network card of the configuration computer or a valid network connection of
the internal network (LAN).
1.3.3
Service contacts
A push button or an on/off switch (e.g., key switch) can be connected between service
contacts CMD V+ and CMD.
The contacts ACK (+) and FAULT (+) are non-floating, continuously short-circuit-proof
and supply a maximum of 250
mA.
NOTE:
Only connect the mGuard network ports to LAN installations. Some telecommuni-
cations connections also use RJ45 sockets; these must not be connected to the RJ45
sockets of the mGuard.
NOTE:
Do not connect the voltage and ground outputs (GND, CMD V+) to an external
voltage source.
Please note that only the “Service 1” contacts are used with firmware version up to and
including 7.6x. The “Service 2” contacts shall be made available as of firmware version
8.1.
The plug-in screw terminal blocks of the service contacts may be removed or inserted dur-
ing operation of the mGuard.
mGuard
rs4000
mGuard
rs2000
Service 1 + 2
CMD V+
CMD
GND
ACK
Power
P1+
GND
P2+
GND
Voltage out-
put (+)
Supply volt-
age
Switching
input 11 ...
36
V DC
Ground out-
put (-)
Supply volt-
age
Short-cir-
cuit-proof
switching
output *
+24 V
0 V
+24 V
0 V
See Section
1.3.4
Only for mGuard
rs4000
See Section
1.3.4
Contact
GND
AUX
GND
FAULT
Example
Example
Not used
Not used
Signal out-
put (-)
Signal out-
put (+)†
* Maximum of 250 mA at 11 ... 36 V
DC
† 11
V ...
36
V when operating correctly; disconnected in the event of a fault
Innominate Security Technologies
17
The switching inputs and switching outputs can be connected with signals from external de-
vices, e.g., with signals from PLCs. In this case, ensure the same potential as well as voltage
and current specifications are defined.
Depending on the firmware version used, the service contacts can be used for various
switching or signaling tasks.
Service contacts as of firmware version 8.1
Input/CMD I1, CMD I2
Via the web interface under “Management, Service I/O”, you can set whether a push button
or an on/off switch has been connected to the inputs. One or more freely selectable VPN
connections or firewall rule records can be switched via the corresponding switch. A mixture
of VPN connections and firewall rule records is also possible. The web interface displays
which VPN connections and which firewall rule records are connected to this input.
The push button or on/off switch is used to establish and release predefined VPN connec-
tions or the defined firewall rule records.
Operating a connected
push button
•
To switch on the selected VPN connections or firewall rule records, press and hold the
push button for a few seconds and then release the push button.
•
To switch off the selected VPN connections or firewall rule records, press and hold the
push button for a few seconds and then release the push button.
Operating a connected
on/off switch
•
To switch on the selected VPN connections or firewall rule records, set the switch to
ON.
•
To switch off the selected VPN connections or firewall rule records, set the switch to
OFF.
Signal contact (signal out-
put) ACK O1, O2
Via the web interface under “Management,
Service I/O” you can set whether certain VPN
connections or firewall rule records are monitored and displayed via the LED Info
1 (out-
put/ACK O1) or LED Info
2 (output/ACK
O2).
If VPN connections are being monitored, an illuminated Info LED indicates that VPN con-
nections are established.
Alarm output ACK O3
The O3 alarm output monitors the function of the mGuard
rs4000/rs2000 and therefore en-
ables remote diagnostics.
The Fault LED lights up red if the signal output takes low level due to an error (inverted
logic).
The O3 alarm output reports the following when “Management,
Service I/O, Alarm output”
has been activated.
–
Failure of the redundant supply voltage
–
Monitoring of the link status of the Ethernet connections
–
Monitoring of the temperature condition
–
Monitoring of the connection state of the internal modem
Innominate Security Technologies
I15007_en_02
Service contacts up to firmware version 8.0
The push button or on/off switch is used to establish and release a predefined VPN connec-
tion.
The output indicates the status of the VPN connection (in the web interface under “IPsec
VPN >> Global >> Options”).
Operating a connected
push button
•
To establish the VPN connection, hold down the button for a few seconds until the INFO
LED flashes. Only then release the button.
Flashing indicates that the mGuard has received the command to establish the VPN
connection and is establishing the VPN connection. As soon as the VPN connection is
established, the INFO LED remains lit continuously.
•
To release the VPN connection, hold down the button for a few seconds until the signal
output flashes or goes out. Only then release the button.
As soon as the INFO LED goes out, the VPN connection is released.
Operating a connected
on/off switch
•
To establish the VPN connection, set the switch to the ON position.
•
To release the VPN connection, set the switch to the OFF position.
INFO LED
If the INFO LED does not light up, this generally indicates that the defined VPN connection
is not present. Either the VPN connection was not established or it has failed due to an error.
If the INFO LED is illuminated, the VPN connection is present.
If the INFO LED is flashing, the VPN connection is being established or released.
Signal contact (signal out-
put)
The signal contact monitors the function of the mGuard
rs4000/rs2000 and thus enables re-
mote diagnostics.
The FAULT LED lights up red if the signal output takes low level due to an error (inverted
logic).
The voltage at the signal contact corresponds to the supply voltage applied. The following
is reported when monitoring the output voltage:
–
Failure of at least one of the two supply voltages.
–
Power supply of the mGuard
rs4000/rs2000 below the limit value (supply voltage 1
and/or 2 lower than 11
V).
–
Link status monitoring of the Ethernet connections, if configured. By default upon deliv-
ery, the connection is not monitored. Monitoring can be activated (on the web interface
under “Management >> System Settings >> Signal Contact”).
–
Error during selftest.
During a restart, the signal contact is switched off until the mGuard
rs4000/rs2000 has
started up completely. This also applies when the signal contact is manually set to “Closed”
under “Manual settings” in the software configuration.
Innominate Security Technologies
19
1.3.4
Connecting the supply voltage
The supply voltage is connected via a plug-in screw terminal block, which is located on the
top of the device.
Figure
1-4
Connecting the supply voltage
The mGuard
rs4000 has a redundant supply voltage. If you only connect one supply volt-
age, you will get an error message.
•
Remove the plug-in screw terminal blocks for the power supply and the service con-
tacts.
•
Do not connect the service contacts to an external voltage source.
•
Wire the supply voltage lines with the corresponding screw terminal block (P1/P2) of
the mGuard. Tighten the screws on the screw terminal blocks with 0.5
...
0.8
Nm.
•
Insert the screw terminal blocks into the intended sockets on the top of the mGuard (see
Figure
1-4).
Status LED P1 lights up green when the supply voltage has been connected properly. On
the mGuard
rs4000, the status indicator P2 also lights up if there is a redundant supply volt-
age connection.
The mGuard boots the firmware. Status STAT LED flashes green. The mGuard is ready for
operation as soon as the Ethernet socket LEDs light up. Additionally, status LEDs P1/P2
light up green and the status STAT LED flashes green at heartbeat.
Redundant voltage supply (mGuard
rs4000)
A redundant supply voltage can be connected. Both inputs are isolated. The load is not dis-
tributed. With a redundant supply, the power supply unit with the higher output voltage sup-
plies the mGuard
rs4000 alone. The supply voltage is electrically isolated from the housing.
If the supply voltage is not redundant, the mGuard
rs4000 indicates the failure of the supply
voltage via the signal contact. This message can be prevented by feeding the supply volt-
age via both inputs (P1/P2) or by installing an appropriate wire jumper between connections
P1 and P2.
WARNING:
The mGuard
rs4000/rs2000 is designed for operation with a DC voltage of
11
V DC
...
36
V DC/SELV, 1.5
A, maximum.
Therefore, only SELV circuits with voltage limitations according to EN 60950-1 may be
connected to the supply connections and the signal contact.
+24 V 0 V
+24 V 0 V
P1
P2
+24 V 0 V
P1
mGuard
rs2000
mGuard
rs4000
Innominate Security Technologies
I15007_en_02
1.4
Preparing the configuration
1.4.1
Connection requirements
–
The mGuard
rs4000/rs2000 must be connected to at least one active power supply
unit.
–
For local configuration: The computer that is to be used for configuration must be
connected to the LAN socket on the mGuard.
–
For remote configuration: The mGuard must be configured so that remote configura-
tion is permitted.
–
The mGuard must be connected, i.e.,
the required connections must be working.
1.4.2
Local configuration on startup (EIS)
As of firmware version 7.2, initial startup of mGuard products provided in Stealth mode is
considerably easier. From this version onwards, the EIS (Easy Initial Setup) procedure en-
ables startup to be performed via preset or user-defined management addresses without
actually having to connect to an external network.
The mGuard is configured using a web browser on the computer used for configuration.
According to the default setting, the mGuard can be accessed via the following addresses:
The mGuard is preset to the “multiple Clients” stealth configuration. You need to configure
a management
IP address and default gateway if you want to use VPN connections (see
Page
24). Alternatively, you can select a different stealth configuration or use another net-
work mode.
NOTE:
The web browser used must support SSL encryption (i.e.,
HTTPS).
Table
1-3
Preset addresses
Default setting
Network mode
Management IP #1
Management IP #2
mGuard
rs4000
Stealth
https://1.1.1.1/
https://192.168.1.1/
mGuard
rs2000
Stealth
https://1.1.1.1/
https://192.168.1.1/
Innominate Security Technologies
21
1.5
Configuration in Stealth mode
On initial startup, the mGuard can be accessed via two addresses:
–
https://192.168.1.1/ (see Page
22)
–
https://1.1.1.1/ (see Page
22)
Alternatively, an IP address can be assigned via BootP (see “Assigning the IP address via
BootP” on page
23).
The mGuard can be accessed via https://192.168.1.1/ if the external network interface is not
connected on startup.
Computers can access the mGuard via https://1.1.1.1/ if they are directly or indirectly con-
nected to the LAN port of the mGuard. For this purpose, the mGuard with LAN port and
WAN port must be integrated in an operational network in which the default gateway can be
accessed via the WAN port.
–
After access via IP address 192.168.1.1 and successful login, IP address
192.168.1.1 is set as a fixed management
IP address.
–
After access via IP address 1.1.1.1 or after IP address assignment via BootP, the
product can no longer be accessed via IP address 192.168.1.1.
Innominate Security Technologies
I15007_en_02
1.5.1
IP address 192.168.1.1
To access the configuration interface, it may be necessary to adapt the network configura-
tion of your computer.
Under Windows 7, proceed as follows:
•
In the Control Panel, open the “Network and Sharing Center”.
•
Click on “LAN connection”. (The “LAN connection” item is only displayed if a connection
exists from the LAN interface on the computer to a mGuard in operation or another part-
ner).
•
Click on “Properties”.
•
Select the menu item “Internet protocol Version 4 (TCP/IPv4)”.
•
Click on “Properties”.
•
First select “Use the following IP address” under “Internet Protocol Version 4 Proper-
ties”, then enter the following address, for example:
1.5.2
IP address https://1.1.1.1/
With a configured network
interface
In order for the mGuard to be addressed via address https://1.1.1.1/, it must be connected
to a configured network interface. This is the case if it is connected in an existing network
connection and if the default gateway can be accessed via the WAN port of the mGuard at
the same time.
In this case, the web browser establishes a connection to the mGuard configuration inter-
face after the address https://1.1.1.1/ is entered (see “Establishing a local configuration con-
nection” on page
24). Continue from this point.
In Stealth mode, the mGuard can be accessed via the LAN interface via IP address
192.168.1.1 within network 192.168.1.0/24, if one of the following conditions applies.
–
The mGuard is in the delivery state.
–
The mGuard was reset to the default settings via the web interface and restarted.
–
The rescue procedure (flashing of the mGuard) or the recovery procedure has been
performed.
IP address:
192.168.1.2
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
Depending on the configuration of the mGuard, it may then be necessary to adapt the net-
work interface of the locally connected computer or network accordingly.
After access via IP address 1.1.1.1, the product can no longer be accessed via IP address
192.168.1.1
Innominate Security Technologies
23
1.5.3
Assigning the IP address via BootP
For IP address assignment, the mGuard uses the BootP protocol. The IP address can also
be assigned via BootP. On the Internet, numerous BootP servers are available. You can use
any of these programs for address assignment.
Section 14.1 explains IP address assignment using the free Windows software
“IP
Assignment
Tool” (IPAssign.exe).
Notes for BootP
During initial startup, the mGuard transmits BootP requests without interruption until it re-
ceives a valid IP address. After receiving a valid IP address, the mGuard no longer sends
BootP requests. The product can then no longer be accessed via IP address 192.168.1.1.
After receiving a BootP reply, the mGuard no longer sends BootP requests, not even after
it has been restarted. For the mGuard to send BootP requests again, it must either be set to
the default settings or one of the procedures (recovery or flash) must be performed.
Requirements
The mGuard is connected to a computer using a Microsoft Windows operating system.
After assigning an IP address via BootP, the product can no longer be accessed via IP ad-
dress 192.168.1.1
Innominate Security Technologies
I15007_en_02
1.6
Establishing a local configuration connection
Web-based administrator
interface
The mGuard is configured via a web browser that is executed on the configuration com-
puter.
The mGuard can be accessed via one of the following addresses:
Proceed as follows:
•
Start a web browser.
•
Make sure that the browser, when it is started, does not automatically establish a con-
nection as otherwise the connection establishment to the mGuard may be more diffi-
cult.
In Internet Explorer, make the following settings:
•
In the “Tools” menu, select “Internet Options” and click on the “Connections” tab:
•
Under “Dial-up and Virtual Private Network settings”, select “Never dial a connection”.
•
Enter the address of the mGuard completely into the address line of the web browser
(refer to Table
1-4).
You access the administrator website of the mGuard.
If the administrator web page of the mGuard cannot be accessed
If you have forgotten the
configured address
If the address of the mGuard in Router, PPPoE or PPTP mode has been set to a different
value, and the current address is not known, the mGuard must be reset to the default set-
tings specified above for the IP address using the Recovery procedure (see “Performing a
recovery procedure” on page
28).
If the administrator web
page is not displayed
If the web browser repeatedly reports that the page cannot be displayed, try the following:
•
Check whether the default gateway of the connected configuration computer is initial-
ized (see “Local configuration on startup (EIS)” on page
20).
•
Disable any active firewalls.
•
Make sure that the browser does not use a proxy server.
In Internet Explorer (Version 8), make the following settings: “Tools” menu, “Internet
Options”, “Connections” tab.
Click on “Properties” under “LAN settings”.
Check that “Use a proxy server for your LAN” (under “Proxy server”) is not activated in
the “Local Area Network (LAN) Settings” dialog box.
•
If other LAN connections are active on the computer, deactivate them until the configu-
ration has been completed.
Under the Windows menu “Start, Settings, Control Panel, Network Connections” or
“Network and Dial-up Connections”, right-click on the corresponding icon and select
“Disable” in the context menu.
NOTE:
The web browser used must support SSL encryption (i.e.,
HTTPS).
Table
1-4
Preset addresses
Default setting
Network
mode
Management IP #1
Management IP #2
mGuard
rs4000
Stealth
https://1.1.1.1/
https://192.168.1.1/
mGuard
rs2000
Stealth
https://1.1.1.1/
https://192.168.1.1/
Innominate Security Technologies
25
After successful connection establishment
Once a connection has been established successfully, a security alert may be displayed.
Explanation:
As administrative tasks can only be performed using encrypted access, a self-signed certif-
icate is supplied with the device.
•
Click “Yes” to acknowledge the security alert.
The login window is displayed.
Figure
1-5
Login
•
To log in, enter the preset user name and password (please note these settings are
case-sensitive):
The mGuard can then be configured via the web interface.
For additional information,
please refer to the software reference manual.
User Name:
admin
Password:
mGuard
For security reasons, we recommend you change the default root and administrator pass-
words during initial configuration.
Innominate Security Technologies
I15007_en_02
1.7
Remote configuration
Requirement
The mGuard must be configured so that remote configuration is permitted.
The option for remote configuration is disabled by default.
Switch on the remote configuration option in the web interface under “Management >> Web
Settings”.
How to proceed
To configure the mGuard via its web user interface from a remote computer, establish the
connection to the mGuard from there.
Proceed as follows:
•
Start the web browser on the remote computer.
•
Under address, enter the IP address where the mGuard can be accessed externally
over the Internet or WAN, together with the port number (if required).
Example
If the mGuard can be accessed over the Internet, for example, via address
https://123.45.67.89/ and port number 443 has been specified for remote access, the fol-
lowing address must be entered in the web browser of the remote peer:
https://123.45.67.89/
If a different port number is used, it should be entered after the IP address, e.g.,
https://123.45.67.89:442/
Configuration
The mGuard can then be configured via the web interface.
For additional information,
please refer to the software reference manual.
Innominate Security Technologies
27
1.8
Restart, recovery procedure, and flashing the firm-
ware
The Reset button is used to set the device to one of the following states:
–
Performing a restart
–
Performing a recovery procedure
–
Flashing the firmware/rescue procedure
Figure
1-6
Reset button
1.8.1
Performing a restart
Objective
The device is restarted with the configured settings.
Action
•
Press the Reset button for around 1.5 seconds until the ERR LED lights up.
(Alternatively, disconnect the power supply and then connect it again.)
Reset button
Innominate Security Technologies
I15007_en_02
1.8.2
Performing a recovery procedure
Objective
The network configuration (but not the rest of the configuration) is to be reset to the delivery
state, as it is no longer possible to access the mGuard.
When performing the recovery procedure, the default settings are established:
The mGuard is reset to Stealth mode with the default setting “multiple Clients”.
–
The CIFS integrity monitoring function is also disabled because this only works when
the management IP is active.
–
In addition, MAU management is switched on for Ethernet connections. HTTPS access
is enabled via the local Ethernet connection (LAN).
–
The settings configured for VPN connections and the firewall are retained, including
passwords.
Possible reasons for performing the recovery procedure:
–
The mGuard is in Router or PPPoE mode.
–
The configured device address of the mGuard differs from the default setting.
–
The current IP address of the device is not known.
Action
•
Slowly press the Reset button six times.
After approximately 2 seconds, the STAT LED lights up green.
•
Press the Reset button slowly again six times.
If successful, the STAT LED lights up green.
If unsuccessful, the ERR LED lights up red.
If successful, the device restarts after two seconds and switches to Stealth mode. The de-
vice can then be reached again under the corresponding addresses.
Table
1-5
Preset addresses
Default setting
Network
mode
Management IP #1
Management IP #2
mGuard
rs4000
Stealth
https://1.1.1.1/
https://192.168.1.1/
mGuard
rs2000
Stealth
https://1.1.1.1/
https://192.168.1.1/
Up-to-date information on the recovery and flashing procedure can be found in the appli-
cation note for your mGuard firmware version.
You can find application notes under the following Internet address:
www.innominate.com.
Innominate Security Technologies
29
1.8.3
Flashing the firmware/rescue procedure
Objective
The entire firmware of the mGuard should be reloaded on the device.
–
All configured settings are deleted. The mGuard is set to the delivery state.
–
In Version 5.0.0 or later of the mGuard, the licenses installed on the mGuard are re-
tained after flashing the firmware. Therefore, they do not have to be installed again.
Possible reasons
The administrator and root password have been lost.
Requirements
Requirements for flashing
–
The mGuard firmware has been obtained from your dealer's support team or the
www.innominate.com website and has been saved on a compatible SD card.
–
This SD card has been inserted into the mGuard.
–
The relevant firmware files are available for download from the download page of
www.innominate.com. The files must be located under the following path names or in
the following folders on the SD card:
Firmware/install-ubi.mpc83xx.p7s
Firmware/ubifs.img.mpc83xx.p7s
NOTE:
During flashing, the firmware is always loaded from an SD card first. The firmware
is only loaded from a TFTP server if no SD card is found.
The following requirements apply when loading the firmware from an SD card:
–
All necessary firmware files must be located in a common directory on the first parti-
tion of the SD card
–
This partition must use a VFAT file system (standard type for SD cards).
To flash the firmware from a TFTP server, a TFTP server must be installed on the locally
connected computer (see “Installing the DHCP and TFTP server” on page
258).
NOTE:
Installing a second DHCP server in a network could affect the configuration of the
entire network.
Innominate Security Technologies
I15007_en_02
Action
To flash the firmware or to perform the rescue procedure, proceed as follows:
•
Hold down the Reset button until the STAT, MOD, and SIG LEDs light up green. Then,
the mGuard is in the recovery state.
•
Release the Reset button within a second of entering the recovery state.
If the Reset button is not released, the mGuard is restarted.
The mGuard now starts the recovery system: It searches for a DHCP server via the LAN
interface in order to obtain an IP address.
The STAT LED flashes.
The “install.p7s” file is loaded from the TFTP server or SD card. It contains the electron-
ically signed control procedure for the installation process. Only files that are signed are
executed.
The control procedure deletes the current contents of the Flash memory and prepares
for a new firmware installation.
The STAT, MOD, and SIG LEDs form a running light.
The “jffs2.img.p7s” firmware file is downloaded from the TFTP server or SD card and
written to the Flash memory. This file contains the actual mGuard operating system and
is signed electronically. Only files signed by Innominate are accepted.
This process takes around 3 to 5 minutes. The STAT LED is lit continuously.
The new firmware is extracted and configured. This procedure takes 1 to 3 minutes.
As soon as the procedure is complete, the STAT, MOD, and SIG LEDs flash green simulta-
neously.
•
Restart the mGuard. To do this, briefly press the Reset button.
(Alternatively, disconnect the power supply and then connect it again.)
The mGuard is in the delivery state. You can now configure it again (see “Establishing a
local configuration connection” on page
24).
NOTE:
Do not interrupt the power supply to the mGuard during any stage of the flashing
procedure. Otherwise, the device could be damaged and may have to be reactivated by
the manufacturer.
Innominate Security Technologies
31
1.9
Technical data
Hardware properties
mGuard
rs4000
mGuard
rs2000
Platform
Freescale network processor with
330
MHz clocking
Freescale network processor with
330
MHz clocking
Network interfaces
1 LAN port | 1 WAN port
Ethernet IEEE 802.3 10/100-BaseTX
RJ45 | full duplex | auto MDIX
1 LAN port | 1 WAN port
Ethernet IEEE 802.3 10/100-BaseTX
RJ45 | full duplex | auto MDIX
Other interfaces
Serial RS-232 | D-SUB 9 connector
2 digital inputs and 2 digital outputs
Serial RS-232 | D-SUB 9 connector
2 digital inputs and 2 digital outputs
Memory
128 MB RAM | 128 MB Flash | SD card
Replaceable configuration memory
128 MB RAM | 128 MB Flash | SD card
Replaceable configuration memory
Redundancy options
Optional: VPN | router and firewall
Not available
Power supply
Voltage range 11 ... 36 V DC, redundant
Voltage range 11 ... 36 V DC
Power consumption
2.13 W, typical
2.13 W, typical
Humidity range
5% ... 95% (operation, storage), non-con-
densing
5% ... 95% (operation, storage), non-con-
densing
Degree of protection
IP20
IP20
Temperature range
-20°C ... +60°C (operation)
-20°C ... +60°C (storage)
-20°C ... +60°C (operation)
-20°C ... +60°C (storage)
Dimensions (H x W x D)
130 x 45 x 114 mm (up to DIN rail support)
130 x 45 x 114 mm (up to DIN rail support)
Weight
725 g (TX/TX)
722 g (TX/TX)
Firmware and power values
mGuard
rs4000
mGuard
rs2000
Firmware compatibility
For mGuard v7.4.0 or later: Innominate recommends the use of the latest firmware ver-
sion and patch releases in each case.
For the scope of functions, please refer to the relevant firmware data sheet.
Data throughput (router | firewall)
Router mode, default firewall rules, bidirectional throughput: 99 Mbps, maximum
Stealth mode, default firewall rules, bidirectional throughput: 50 Mbps, maximum.
Virtual Private Network (VPN)
IPsec (IETF standard)
Up to 250 VPN tunnels
IPsec (IETF standard)
Up to 2 VPN tunnels
Hardware-based encryption
DES | 3DES | AES-128/192/256
DES | 3DES | AES-128/192/256
Encrypted VPN throughput (AES-256)
Router mode, default firewall rules, bidirectional throughput: 35
Mbps, maximum
Stealth mode, default firewall rules, bidirectional throughput: 25
Mbps, maximum
Management support
Web GUI (HTTPS) | command line interface (SSH) | SNMP v1/2/3 | central device man-
agement software
Diagnostics
LEDs (Power 1 + 2, State, Error, Signal,
Fault, Modem, Info) signal contacts | ser-
vice contacts | log file | remote syslog
LEDs (Power, State, Error, Signal, Fault,
Modem, Info) signal contacts | service
contacts | log file | remote syslog
Other
Conformance
CE | FCC | UL 508
ANSI/ISA 12.12 Class I Div. 2
Special features
Realtime clock | Trusted Platform Module (TPM) | temperature sensor |
mGuard Remote
Services Portal ready
Innominate Security Technologies
33
2
mGuard
rs4000/rs2000 Switch
Table
2-1
Available mGuard
rs4000/rs2000 Switch versions
The mGuard
rs4000
Switch is suitable for distributed protection of production cells or in-
dividual machines against manipulation.
It features a 4-port managed LAN switch, one WAN port and one DMZ port, and a serial in-
terface.
The serial interface can be switched to the WAN interface as redundancy path, for example.
A dedicated DMZ port with its own firewall rules enables segmentation and differentiated
safety concepts. You can integrate automation devices with serial interfaces into networks,
as a COM server is integrated.
For software-independent remote maintenance, the mGuard
rs4000
Switch can be used as
a VPN router for up to 250 parallel, IPsec-encrypted VPN tunnels.
The mGuard
rs2000
Switch is a version with basic firewall and can be used as a VPN cli-
ent for up to two parallel, IPsec-encrypted VPN tunnels. It is suitable for secure remote
maintenance applications and enables connection of globally distributed machines and
controllers.
Both versions support a replaceable configuration memory in the form of an SD card. To in-
crease safety, VPN connections can be switched on or off via a switch contact or software
interface. The fanless metal housing is mounted on a DIN rail.
Figure
2-1
mGuard
rs4000
Switch/mGuard
rs2000
Switch
Available versions
Order No.
mGuard rs4000 4TX/TX
HW-107020
mGuard rs4000 4TX/TX VPN
BD-702000
mGuard rs2000 5TX/TX VPN
HW-108020
Innominate Security Technologies
I15007_en_02
2.1
Operating elements and LEDs
Figure
2-2
Operating elements and LEDs on the mGuard
rs4000
Switch
Plug-in screw terminal
blocks, for assignment, refer
to page
39 and page
41
Reset button
LEDs, see Table
2-2
DMZ port
WAN port
LAN port (protected)
LAN port (protected)
LAN port (protected)
Slot for optional SD card
LAN port (protected)
RS-232 interface
(bottom)
Table
2-2
LEDs on the mGuard
rs4000
Switch and mGuard
rs2000
Switch
LED
State
Meaning
P1
Green
On
Power supply 1 is active
P2
Green
On
Power supply 2 is active (mGuard
rs2000
Switch: not used)
Stat
Green
Flashing
Heartbeat. The device is correctly connected and operating.
Err
Red
Flashing
System error. Restart the device.
–
Press the reset button shortly (for 1.5 seconds).
–
Alternatively, briefly disconnect the device power supply and then connect it
again.
If the error is still present, start the recovery procedure (see page
47) or contact
your dealer.
Stat + Err
Flashing alternately:
green and red
Boot process. When the device has been connected to the power supply. After a
few seconds, this LED changes to the heartbeat state.
Mod
Green
On
Connection via modem established
Fault
Red
On
The signal output takes low level due to an error (inverted logic). The signal output
is inactive during a restart.
Innominate Security Technologies
35
Info2
Green
On
The configured VPN connections are established at output O1 or the firewall re-
cords defined at output O1 are activated.
Flashing
The configured VPN connections are being established or aborted at output O1 or
the firewall rule records defined at output O1 are activated or deactivated.
Info1
Green
On
The configured VPN connections are established at output O2 or the firewall re-
cords defined at output O2 are activated.
Flashing
The configured VPN connections are being established or aborted at output O2 or
the firewall rule records defined at output O2 are activated or deactivated.
WAN 1
Green
On
The LEDs are located in the sockets (10/100 and duplex LED)
Ethernet status. The LEDs indicate the status of the relevant port. As soon as the
device is connected to the relevant network, a continuous light indicates that there
is a connection to the network partner in the LAN, WAN or DMZ. When data pack-
ets are transmitted, the LED goes out briefly.
DMZ11
Green
On
LAN 1–4/52
Green
On
1 mGuard
rs4000
Switch only
2 mGuard
rs2000
Switch only
Table
2-2
LEDs on the mGuard
rs4000
Switch and mGuard
rs2000
Switch [...]
LED
State
Meaning
Innominate Security Technologies
I15007_en_02
2.2
Startup
2.2.1
Safety notes
To ensure correct operation and the safety of the environment and of personnel, the device
must be installed, operated, and maintained correctly.
General notes regarding usage
2.2.2
Checking the scope of supply
Before startup, check the scope of supply to ensure nothing is missing.
The scope of supply includes:
–
Device
–
Package slip
–
Plug-in screw terminal blocks for the power supply connection and inputs/outputs (in-
serted)
2.2.3
mGuard-Firmware
The device must be operated with mGuard-Firmware version 8.1.5 or higher.
NOTE:
Risk of material damage due to incorrect wiring
Only connect the device network ports to LAN installations. Some telecommunications
connections also use RJ45 sockets; these must not be connected to the RJ45 sockets of
the device.
For connecting a modem or serial terminal to the RS-232 interface, you will need a null
modem cable not exceeding 10
m in length.
NOTE:
Risk of damage to equipment due to noise emissions
This is a Class A item of equipment. This equipment can cause radio interference in resi-
dential areas; in this case, the operator may be required to implement appropriate mea-
sures.
NOTE:
Electrostatic discharge
When handling the device, observe the necessary safety precautions against electrostat-
ic discharge (ESD) in accordance with EN
61340-5-1 and IEC
61340-5-1.
NOTE:
Select suitable ambient conditions
–
Ambient temperature:
-20°C
...
+60°C
–
Maximum humidity, non-condensing:
5%
...
95%
To avoid overheating, do not expose the device to direct sunlight or other heat sources.
NOTE:
Cleaning
Clean the device housing with a soft cloth. Do not use aggressive solvents.
Innominate Security Technologies
37
2.3
Installing the mGuard
rs4000/rs2000 Switch
2.3.1
Mounting/removal
Mounting
The device is ready to operate when it is supplied. The recommended sequence for mount-
ing and connection is as follows:
•
Mount the mGuard
rs4000/rs2000 Switch on a grounded 35 mm DIN rail according to
DIN
EN
60715.
Figure
2-3
Mounting the mGuard
rs4000/rs2000 Switch on a DIN rail
•
Attach the top snap-on foot of the mGuard
rs4000/rs2000 Switch to the DIN rail and
then press the mGuard
rs4000/rs2000 Switch down towards the DIN rail until it engag-
es with a click.
Removal
•
Remove or disconnect the connections.
•
To remove the mGuard
rs4000/rs2000 Switch from the DIN rail, insert a screwdriver
horizontally in the locking slide under the housing, pull it down – without tilting the
screwdriver – and then pull up the mGuard
rs4000/rs2000 Switch.
NOTE:
Device damage
Only mount and remove devices when the power supply is disconnected.
Innominate Security Technologies
I15007_en_02
2.3.2
Connecting to the network
•
Connect the device to the network. To do this, you need a suitable UTP cable (CAT5)
which is not included in the scope of supply.
•
Connect the internal network interface LAN of the device to the corresponding Ethernet
network card of the configuration computer or a valid network connection of the internal
network (LAN).
NOTE:
Risk of material damage due to incorrect wiring
Only connect the device network ports to LAN installations. Some telecommunications
connections also use RJ45 sockets; these must not be connected to the RJ45 sockets of
the device.
Innominate Security Technologies
39
2.3.3
Connecting the service contacts
The mGuard
rs4000/rs2000 Switch has three digital inputs and outputs. These are config-
ured in the web interface, e.g., as a control signal for starting and stopping VPN connec-
tions.
The digital inputs and outputs are connected as follows.
A push button or an on/off switch (e.g., key switch) can be connected between service
contacts CMD V+ and CMD.
The contacts ACK (+) and FAULT (+) are non-floating, continuously short-circuit-proof
and supply a maximum of 250
mA.
The switching inputs and switching outputs can be connected with signals from external de-
vices, e.g., with signals from PLCs. In this case, ensure the same potential as well as voltage
and current specifications are defined.
Depending on the firmware version used, the service contacts can be used for various
switching or signaling tasks.
NOTE:
Do not connect the voltage and ground outputs to an external voltage source.
The plug-in screw terminal blocks of the service contacts may be removed or inserted dur-
ing operation of the device.
mGuard
rs4000
Switch
mGuard
rs2000
Switch
Service 1 + 2
CMD V+
CMD
GND
ACK
Power
P1+
GND
P2+
GND
Voltage out-
put (+)
Supply volt-
age
Switching
input 11 ...
36
V DC
Ground out-
put (-)
Supply volt-
age
Short-cir-
cuit-proof
switching
output 1
+24 V
0 V
+24 V
0 V
See Section
2.3.4
Only for mGuard
rs4000
See Section
2.3.4
Contact
GND
AUX
GND
FAULT
Example
Example
Not used
Not used
Signal out-
put (-)
Signal out-
put (+)2
1 Maximum of 250 mA at 11 ... 36 V
DC
2 11
V ...
36
V when operating correctly; disconnected in the event of a fault
Innominate Security Technologies
I15007_en_02
Service contacts as of firmware version 8.1
Input/CMD I1, CMD I2
Via the web interface under “Management, Service I/O”, you can set whether a push button
or an on/off switch has been connected to the inputs. One or more freely selectable VPN
connections or firewall rule records can be switched via the corresponding switch. A mixture
of VPN connections and firewall rule records is also possible. The web interface displays
which VPN connections and which firewall rule records are connected to this input.
The push button or on/off switch is used to establish and release predefined VPN connec-
tions or the defined firewall rule records.
Operating a connected
push button
•
To switch on the selected VPN connections or firewall rule records, press and hold the
push button for a few seconds and then release the push button.
•
To switch off the selected VPN connections or firewall rule records, press and hold the
push button for a few seconds and then release the push button.
Operating a connected
on/off switch
•
To switch on the selected VPN connections or firewall rule records, set the switch to
ON.
•
To switch off the selected VPN connections or firewall rule records, set the switch to
OFF.
Signal contact (signal out-
put) ACK O1, O2
Via the web interface under “Management,
Service I/O” you can set whether certain VPN
connections or firewall rule records are monitored and displayed via the LED Info
1 (out-
put/ACK O1) or LED Info
2 (output/ACK
O2).
If VPN connections are being monitored, an illuminated Info LED indicates that VPN con-
nections are established.
Alarm output ACK O3
The O3 alarm output monitors the function of the mGuard
rs4000/rs2000 and therefore en-
ables remote diagnostics.
The Fault LED lights up red if the signal output takes low level due to an error (inverted
logic).
The O3 alarm output reports the following when “Management,
Service I/O, Alarm output”
has been activated.
–
Failure of the redundant supply voltage
–
Monitoring of the link status of the Ethernet connections
–
Monitoring of the temperature condition
–
Monitoring of the connection state of the internal modem
Innominate Security Technologies
41
2.3.4
Connecting the supply voltage
The supply voltage is connected via a plug-in screw terminal block, which is located on the
top of the device.
Figure
2-4
Connecting the supply voltage
The mGuard
rs4000
Switch has a redundant supply voltage. If you only connect one supply
voltage, you will get an error message.
•
Remove the plug-in screw terminal blocks for the power supply and the service con-
tacts.
•
Wire the supply voltage lines with the corresponding screw terminal block (P1/P2) of
the mGuard. Tighten the screws on the screw terminal blocks with 0.5
...
0.8
Nm.
•
Insert the plug-in screw terminal blocks into the intended sockets on the top of the de-
vice.
The P1 status LED lights up green when the supply voltage has been connected properly.
On the mGuard
rs4000
Switch, the P2 LED also lights up if there is a redundant supply volt-
age connection.
The device boots the firmware. The Stat LED flashes green. The device is ready for opera-
tion as soon as the Ethernet socket LEDs light up. Additionally, the P1/P2 LEDs light up
green and Stat LED flashes green at heartbeat.
Redundant power supply (mGuard
rs4000
Switch)
A redundant supply voltage can be connected. Both inputs are isolated. The load is not dis-
tributed. With a redundant supply, the power supply unit with the higher output voltage sup-
plies the mGuard
rs4000
Switch alone. The supply voltage is electrically isolated from the
housing.
If the supply voltage is not redundant, the mGuard
rs4000
Switch indicates the failure of one
supply voltage via the signal contact. This message can be prevented by feeding the supply
voltage via both inputs or by installing an appropriate wire bridge between the connections.
WARNING:
The device is designed for operation with a DC voltage of
11
V DC
...
36
V DC/SELV.
Therefore, only SELV circuits with voltage limitations according to
IEC
60950/EN
60950/VDE
0805 may be connected to the supply connections and the
signal contact.
+24 V 0 V
+24 V 0 V
P1
P2
+24 V 0 V
P1
mGuard
rs2000
Switch
mGuard
rs4000
Switch
Innominate Security Technologies
I15007_en_02
2.4
Preparing the configuration
2.4.1
Connection requirements
–
The mGuard
rs4000/rs2000 Switch must be connected to at least one active power
supply unit.
–
For local configuration: The computer that is to be used for configuration must be
connected to the LAN socket on the device.
–
For remote configuration: The device must be configured so that remote configura-
tion is permitted.
–
The device must be connected, i.e.,
the required connections must be working.
2.5
Configuration in Router mode
On initial startup, the mGuard can be accessed via the following address:
–
https://192.168.1.1
2.5.1
IP address 192.168.1.1
To access the configuration interface, it may be necessary to adapt the network configura-
tion of your computer.
Under Windows 7, proceed as follows:
•
In the Control Panel, open the “Network and Sharing Center”.
•
Click on “LAN connection”. (The “LAN connection” item is only displayed if a connection
exists from the LAN interface on the computer to a mGuard in operation or another part-
ner).
•
Click on “Properties”.
•
Select the menu item “Internet protocol Version 4 (TCP/IPv4)”.
•
Click on “Properties”.
•
First select “Use the following IP address” under “Internet Protocol Version 4 Proper-
ties”, then enter the following address, for example:
–
In Router mode, the mGuard can be accessed via the LAN interface via IP address
192.168.1.1 within network 192.168.1.0/24, if one of the following conditions applies.
–
The mGuard is in the delivery state.
–
The mGuard was reset to the default settings via the web interface and restarted.
–
The rescue procedure (flashing of the mGuard) or the recovery procedure has been
performed.
IP address:
192.168.1.2
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
Depending on the configuration of the mGuard, it may then be necessary to adapt the net-
work interface of the locally connected computer or network accordingly.
Innominate Security Technologies
43
2.6
Establishing a local configuration connection
Web-based administrator
interface
The device is configured via a web browser that is executed on the configuration computer.
The device can be accessed via the following address:
Proceed as follows:
•
Start a web browser.
•
Make sure that the browser, when it is started, does not automatically establish a con-
nection as otherwise the connection establishment to the device may be more difficult.
In Internet Explorer, make the following settings:
•
In the “Tools” menu, select “Internet Options” and click on the “Connections” tab:
•
Under “Dial-up and Virtual Private Network settings”, select “Never dial a connection”.
•
Enter the address of the device completely into the address line of the web browser (re-
fer to Table
2-3).
You access the administrator website of the device.
If the administrator web page of the device cannot be accessed
If you have forgotten the
configured address
If the address of the device in Router, PPPoE or PPTP mode has been set to a different
value, and the current address is not known, the device must be reset to the default settings
specified above for the IP address using the Recovery procedure (see “Performing a recov-
ery procedure” on page
47).
If the administrator web
page is not displayed
If the web browser repeatedly reports that the page cannot be displayed, try the following:
•
Disable any active firewalls.
•
Make sure that the browser does not use a proxy server.
In Internet Explorer (Version 8), make the following settings: “Tools” menu, “Internet
Options”, “Connections” tab.
Click on “Properties” under “LAN settings”.
Check that “Use a proxy server for your LAN” (under “Proxy server”) is not activated in
the “Local Area Network (LAN) Settings” dialog box.
•
If other LAN connections are active on the computer, deactivate them until the configu-
ration has been completed.
Under the Windows menu “Start, Settings, Control Panel, Network Connections” or
“Network and Dial-up Connections”, right-click on the corresponding icon and select
“Disable” in the context menu.
NOTE:
The web browser used must support SSL encryption (i.e.,
HTTPS).
Table
2-3
Preset address
Default setting
Network mode
Management IP #1
mGuard
rs2000
Switch
Router
https://192.168.1.1/
mGuard
rs4000
Switch
Router
https://192.168.1.1/
Innominate Security Technologies
I15007_en_02
After successful connection establishment
Once a connection has been established successfully, a security alert may be displayed.
Explanation
As administrative tasks can only be performed using encrypted access, a self-signed certif-
icate is supplied with the device.
•
Click “Yes” to acknowledge the security alert.
The login window is displayed.
Figure
2-5
Login
•
To log in, enter the preset user name and password (please note these settings are
case-sensitive):
The device can then be configured via the web interface. For additional information, please
refer to software reference manual.
User Name:
admin
Password:
mGuard
For security reasons, we recommend you change the default root and administrator pass-
words during initial configuration.
Innominate Security Technologies
45
2.7
Remote configuration
Requirement
The device must be configured so that remote configuration is permitted.
By default upon delivery, the option for remote configuration is disabled.
Switch on the remote configuration option in the web interface under “Management >> Web
Settings”.
How to proceed
To configure the device via its web user interface from a remote computer, establish the
connection to the device from there.
Proceed as follows:
•
Start the web browser on the remote computer.
•
Under address, enter the IP address where the device can be accessed externally over
the Internet or WAN, together with the port number (if required).
Example
If the device can be accessed over the Internet, for example, via address
https://123.45.67.89/ and port number 443 has been specified for remote access, the fol-
lowing address must be entered in the web browser of the remote peer:
https://123.45.67.89/
If a different port number is used, it should be entered after the IP address, e.g.,
https://123.45.67.89:442/
Configuration
The device can then be configured via the web interface.
For additional information, please
refer to software reference manual.
Innominate Security Technologies
I15007_en_02
2.8
Restart, recovery procedure, and flashing the firm-
ware
The reset button is used to set the device to one of the following states:
–
Performing a restart
–
Performing a recovery procedure
–
Flashing the firmware/rescue procedure
Figure
2-6
Reset button
2.8.1
Performing a restart
Objective
The device is restarted with the configured settings.
Action
•
Press the reset button for around 1.5 seconds until the Err LED lights up.
(Alternatively, disconnect the power supply and then connect it again.)
Reset button
Innominate Security Technologies
47
2.8.2
Performing a recovery procedure
Objective
The network configuration (but not the rest of the configuration) is to be reset to the delivery
state, as it is no longer possible to access the device.
Use the recovery procedure in case you have forgotten the IP address under which the de-
vice can be accessed.
The following network setting is restored:
The mGuard is reset to router mode with the fixed IP address.
–
The CIFS integrity monitoring function is also disabled because this only works when
the management IP is active.
–
In addition, MAU configuration is activated for the Ethernet connections. HTTPS ac-
cess is enabled via the local Ethernet connection (LAN).
–
The settings configured for VPN connections and the firewall are retained, including
passwords.
Possible reasons for performing the recovery procedure:
–
The device is in Router or PPPoE mode.
–
The device address has been configured and is not known.
–
The current IP address of the device is not known.
Action
•
Slowly press the reset button six times.
After approximately two seconds, the Stat LED lights up green.
•
When the Stat LED has gone out, slowly press the reset button again six times.
If successful, the Stat LED lights up green.
If unsuccessful, the Err LED lights up red.
If successful, the device restarts after two seconds and switches to Router mode. The de-
vice can then be reached again under the corresponding address.
Table
2-4
Restored network setting
Network mode
Management IP #1
Management IP #2
Router
https://192.168.1.1/
Up-to-date information on the recovery and flashing procedure can be found in the appli-
cation note for your firmware version.
You can find application notes under the following Internet address: www.innomi-
nate.com.
Innominate Security Technologies
I15007_en_02
2.8.3
Flashing the firmware/rescue procedure
Objective
The entire firmware of the device should be reloaded on the device.
–
All configured settings are deleted. The device is set to the delivery state.
Possible reasons
The administrator and root password have been lost.
Requirements
Requirements for flashing
–
The mGuard firmware has been obtained from your dealer's support team or the
www.innominate.com website and has been saved on a compatible SD card.
–
This SD card has been inserted into the device.
–
The relevant firmware files are available for download from the download page of
www.innominate.com. The files must be located under the following path names in the
following folders on the SD card:
Firmware/install-ubi.mpc83xx.p7s
Firmware/ubifs.img.mpc83xx.p7s
NOTE:
During flashing, the firmware is always loaded from an SD card first. The firmware
is only loaded from a TFTP server if no SD card is found.
The following requirements apply when loading the firmware from an SD card:
–
All necessary firmware files must be located in a common directory on the first parti-
tion of the SD card
–
This partition must use a VFAT file system (standard type for SD cards)
To flash the firmware from a TFTP server, a TFTP server must be installed on the locally
connected computer (see “Installing the DHCP and TFTP server” on page
258).
NOTE:
Installing a second DHCP server in a network could affect the configuration of the
entire network.
Innominate Security Technologies
49
Action
To flash the firmware or to perform the rescue procedure, proceed as follows:
•
Hold down the reset button until the Stat, Mod, and Sig LEDs light up green. The device
then is in rescue status.
•
Release the reset button within one second of entering rescue status.
If the reset button is not released, the mGuard is restarted.
The mGuard now starts the rescue system: It first searches for an inserted SD card and
for the relevant firmware there. If the mGuard does not find an SD card, it searches for
a DHCP server via the LAN interface in order to obtain an IP address.
The Stat LED flashes.
The “install.p7s” file is loaded from the TFTP server or SD card. It contains the electron-
ically signed control procedure for the installation process. Only files that are signed are
executed.
The control procedure deletes the current contents of the Flash memory and prepares
for a new firmware installation.
The Stat, Mod, and Sig LEDs form a running light.
The “jffs2.img.p7s” firmware file is downloaded from the TFTP server or SD card and
written to the Flash memory. This file contains the actual operating system and is
signed electronically. Only files signed by the manufacturer are accepted.
This process takes around 3 to 5 minutes. The Stat LED is lit continuously.
The new firmware is extracted and configured. This procedure takes 1 to 3 minutes.
As soon as the procedure is complete, the Stat, Mod, and Sig LEDs flash green simultane-
ously.
•
Restart the device. To do so, press the reset button.
(Alternatively, disconnect the power supply and then connect it again.)
The device is in the delivery state. You can now configure it again (see “Establishing a local
configuration connection” on page
43).
NOTE:
Do not interrupt the power supply to the device during any stage of the flashing
procedure. Otherwise, the device could be damaged and may have to be reactivated by
the manufacturer.
Innominate Security Technologies
I15007_en_02
2.9
Technical data
Hardware properties
mGuard
rs4000
Switch
mGuard
rs2000
Switch
Platform
Freescale network processor
Freescale network processor
Network interfaces
4 LAN ports (managed) | 1 DMZ port |
1 WAN port
Ethernet IEEE 802.3 10/100 Base TX
RJ45 | full duplex | auto MDIX
5 LAN ports (unmanaged)
Ethernet
IEEE
802.3
10/100-BaseTX
RJ45 | full duplex | auto MDIX
Other interfaces
Serial RS-232 | D-SUB 9 connector
3 digital inputs and 3 digital outputs
Serial RS-232 | D-SUB 9 connector
3 digital inputs and 3 digital outputs
Memory
128-Mbyte RAM | 128-Mbyte Flash
SD card
Replaceable configuration memory
128-Mbyte RAM | 128-Mbyte Flash
SD card
Replaceable configuration memory
Redundancy options
Optional: VPN | router and firewall
–
Power supply
Voltage range 11 ... 36 V DC, redundant
Voltage range 11 ... 36 V DC
Current consumption
Typical < 200 mA (24 V DC) |
Maximum < 800 mA (10 V DC)
Typical < 200 mA (24 V DC) |
Maximum < 800 mA (10 V DC)
Humidity range
5% ... 95% (operation, storage), non-con-
densing
5% ... 95% (operation, storage), non-con-
densing
Degree of protection
IP20
IP20
Temperature range
-20°C ... +60°C (operation)
-20°C ... +70°C (storage)
-20°C ... +60°C (operation)
-20°C ... +70°C (storage)
Dimensions (H x W x D)
130 mm x 45 mm x 114 mm
(up to DIN rail support)
130 mm x 45 mm x 114 mm
(up to DIN rail support)
Weight
835 g
835 g
Firmware and power values
mGuard
rs4000
Switch
mGuard
rs2000
Switch
Firmware compatibility
Firmware 8.1.5: Innominate recommends the use of the latest firmware version and
patch releases in each case.
For the scope of functions, please refer to the relevant firmware data sheet.
Data throughput (router | firewall)
Router mode, default firewall rules, bidirectional throughput: 99 Mbps, maximum
Stealth mode, default firewall rules, bidirectional throughput: 50 Mbps, maximum
When using the DMZ as independent network zone, the maximum possible data
throughput is distributed to the three zones.
Virtual Private Network (VPN)
IPsec (IETF standard)
Up to 250 VPN tunnels
IPsec (IETF standard)
Up to 2
VPN tunnels
Hardware-based encryption
DES | 3DES | AES-128/192/256
DES | 3DES | AES-128/192/256
Encrypted VPN throughput (AES-256)
Router mode, default firewall rules, bidirectional throughput: 35
Mbps, maximum
Stealth mode, default firewall rules, bidirectional throughput: 25
Mbps, maximum
When using the DMZ as independent network zone, the maximum possible data
throughput is distributed to the three zones.
Management support
Web GUI (HTTPS) | command line interface (SSH) | SNMP v1/2/3 | central device man-
agement software
Diagnostics
13 LEDs (Power 1 + 2, State, Error, Signal, Fault, Modem, Info, Signal Status, SIM Sta-
tus) | service I/O | log file | remote Syslog
Other
mGuard
rs4000
Switch
mGuard
rs2000
Switch
Special features
Realtime clock | Trusted Platform Module (TPM) | temperature sensor | mGuard Se-
cure Cloud ready
Innominate Security Technologies
51
3
mGuard
rs4000/rs2000
3G
Table
3-1
Available mGuard
rs4000/rs2000
3G versions
The mGuard
rs4000
3G is suitable for distributed protection of production cells or individ-
ual machines against manipulation.
It features a 4-port managed LAN switch and an industrial 3G mobile communication
modem for GPRS, UMTS, and CDMA networks with a download speed of up to 14.4
Mbps.
The mobile communication interface can be switched to WAN interface as redundancy
path. A dedicated DMZ port with its own firewall rules enables segmentation and differenti-
ated safety concepts. The GPS/GLONASS receiver enables time synchronization and loca-
tion services. You can integrate automation devices with serial interfaces into networks, as
a COM server is integrated.
For software-independent remote maintenance, the mGuard
rs4000
3G can be used as a
VPN router for up to 250 parallel, IPsec-encrypted VPN tunnels.
The mGuard
rs2000
3G is a version with basic firewall and can be used as a VPN client for
up to two parallel, IPsec-encrypted VPN tunnels. It is suitable for secure remote mainte-
nance applications at locations without wired networks and enables global connection of
distributed machines and controllers.
Both versions support a replaceable configuration memory in the form of an SD card. To in-
crease safety, VPN connections can be switched on or off via switch contact, SMS or soft-
ware interface. The fanless metal housing is mounted on a DIN rail.
Figure
3-1
mGuard
rs4000
3G/mGuard
rs2000
3G
Available versions
Order No.
mGuard rs4000 4TX/3G/TX VPN
BD-703000
mGuard rs2000 4TX/3G VPN
HW-108030
Innominate Security Technologies
I15007_en_02
3.1
Operating elements and LEDs
Figure
3-2
Operating elements and LEDs on the mGuard
rs4000
3G
5
4
7
9
8
6
10
11
12
1
2
3
13
14
15
For plug-in screw terminal
blocks, assignment, refer to
Page
57 and Page
62
Reset button
LEDs, see Table
3-2
WAN port
DMZ port
LAN port (protected)
LAN port (protected)
LAN port (protected)
Slot for optional SD card
LAN port (protected)
LEDs, see Table
3-2
SMA
RS-232 interface
Slot for SIM
card 1
Slot for SIM
card 2
RSMA
Antenna sockets
–
SMA (mobile communi-
cation)
–
RSMA (GPS)
Table
3-2
LEDs on the mGuard
rs4000
3G and mGuard
rs2000
3G
LED
State
Meaning
P1
Green
On
Power supply 1 is active
P2
Green
On
Power supply 2 is active (mGuard
rs2000
3G: not used)
Stat
Green
Flashing
Heartbeat. The device is correctly connected and operating.
Err
Red
Flashing
System error. Restart the device.
–
Press the Reset button (for 1.5 seconds).
–
Alternatively, briefly disconnect the device power supply and then connect it
again.
If the error is still present, start the recovery procedure (see Page
69) or contact
your dealer.
Stat + Err
Flashing alternately:
green and red
Boot process. When the device has just been connected to the power supply.
After a few seconds, this LED changes to the heartbeat state.
Mod
Green
On
Connection via modem established
Fault
Red
On
The signal output takes low level due to an error (inverted logic). The signal output
is inactive during a restart.
Innominate Security Technologies
53
Info2
Green
On
Up to firmware version 8.0
As of firmware version 8.1
The configured VPN connection has
been established at output O1.
The configured VPN connections are
established at output O1 or the firewall
rule records defined at output O1 are
activated.
Flashing
The configured VPN connection is
being established or aborted at output
O1.
The configured VPN connections are
being established or aborted at output
O1 or the firewall rule records defined at
output O1 are activated or deactivated.
Info1
Green
On
Up to firmware version 8.0
As of firmware version 8.1
The configured VPN connection has
been established at output O2.
The configured VPN connections are
established at output O2 or the firewall
rule records defined at output O2 are
activated.
Flashing
The configured VPN connection is
being established or aborted at output
O2.
The configured VPN connections are
being established or aborted at output
O2 or the firewall rule records defined at
output O2 are activated or deactivated.
WAN 1*
Green
On
The LEDs are located in the sockets (10/100 and duplex LED)
Ethernet status. The LEDs indicate the status of the relevant port. As soon as the
device is connected to the relevant network, a continuous light indicates that there
is a connection to the network partner in the LAN, WAN or DMZ. When data pack-
ets are transmitted, the LED goes out briefly.
DMZ*
Green
On
LAN 1–4
Green
On
Bar graph
LED 3
Top
Off
Yellow
Yellow
Yellow
LED 2
Middle
Off
Off
Green
Green
LED 1
Bottom
Off
Off
Off
Green
Signal strength
-113
...
111
dBm
-109
...
89
dBm
-87
... 67
dBm
-65
... 51
dBm
Network reception
Very poor to none
Sufficient
Good
Very good
SIM 1
Green
On
Flashing
SIM card 1 active
No PIN or incorrect one entered
SIM 2
Green
On
Flashing
SIM card 2 active
No PIN or incorrect one entered
* only mGuard
rs4000
3G
Table
3-2
LEDs on the mGuard
rs4000
3G and mGuard
rs2000
3G [...]
LED
State
Meaning
Innominate Security Technologies
I15007_en_02
3.2
Startup
3.2.1
Safety notes
To ensure correct operation and the safety of the environment and of personnel, the
mGuard must be installed, operated, and maintained correctly.
General notes regarding usage
3.2.2
Checking the scope of supply
Before startup, check the scope of supply to ensure nothing is missing.
The scope of supply includes:
–
The device
–
Package slip
–
Plug-in screw terminal blocks for the power supply connection and inputs/outputs (in-
serted)
3.2.3
mGuard-Firmware
–
The device must be operated with mGuard-Firmware version 8.0 or higher.
NOTE:
Risk of material damage due to incorrect wiring
Only connect the mGuard network ports to LAN installations. Some telecommunications
connections also use RJ45 sockets; these must not be connected to the RJ45 sockets of
the mGuard.
For connecting a modem or serial terminal to the RS-232 interface, you will need a null
modem cable not exceeding 10 m in length.
NOTE:
Risk of material damage due to emissions
This is a Class A item of equipment. This equipment can cause radio interference in resi-
dential areas; in this case, the operator may be required to implement appropriate mea-
sures.
NOTE:
Electrostatic discharge
When handling the device, observe the necessary safety precautions against electrostat-
ic discharge (ESD) according to EN 61340-5-1 and IEC 61340-5-1.
NOTE:
Select suitable ambient conditions
–
Ambient temperature:
-40°C
...
+60°C
–
Maximum humidity, non-condensing:
5%
...
95%
To avoid overheating, do not expose the mGuard to direct sunlight or other heat sources.
NOTE:
Cleaning
Clean the device housing with a soft cloth. Do not use aggressive solvents.
Innominate Security Technologies
55
3.3
Installation of mGuard
rs4000/rs2000
3G
3.3.1
Mounting/removal
Mounting
The device is ready to operate when it is supplied. The recommended sequence for mount-
ing and connection is as follows:
•
Mount the mGuard
rs4000/rs2000
3G on a grounded 35 mm DIN rail according to
DIN
EN
60715.
Figure
3-3
Mounting the mGuard
rs4000/rs2000
3G on a DIN rail
•
Attach the top snap-on foot of the mGuard
rs4000/rs2000
3G to the DIN rail and then
press the mGuard
rs4000/rs2000
3G down towards the DIN rail until it engages with a
click.
Removal
•
Remove or disconnect the connections.
•
To remove the mGuard
rs4000/rs2000
3G from the DIN rail, insert a screwdriver hori-
zontally in the locking slide under the housing, pull it down – without tilting the screw-
driver – and then pull up the mGuard
rs4000/rs2000
3G.
NOTE:
Device damage
Only mount and remove devices when the power supply is disconnected.
Innominate Security Technologies
I15007_en_02
3.3.2
Connecting to the network
•
Connect the mGuard to the network. To do this, you need a suitable UTP cable (CAT5)
which is not included in the scope of supply. Use UTP cables with an impedance of
100
Ω.
•
Connect the internal network interface LAN of the mGuard to the corresponding Ether-
net network card of the configuration computer or a valid network connection of the in-
ternal network (LAN).
NOTE:
Risk of material damage due to incorrect wiring
Only connect the mGuard network ports to LAN installations. Some telecommunications
connections also use RJ45 sockets; these must not be connected to the RJ45 sockets of
the mGuard.
Innominate Security Technologies
57
3.3.3
Connecting service contacts
The mGuard
rs4000/rs2000
3G has three digital inputs and outputs. These are configured
in the web interface, e.g., the starting and stopping of VPN, sending alarms via SMS etc..
The digital inputs and outputs are connected as follows.
Figure
3-4
Service contacts
A push button or an on/off switch (e.g., key switch) can be connected between service
contacts US and I.
The service contacts O1–O3 are non-floating, continuously short-circuit-proof and supply
a maximum of 250
mA.
The switching inputs and switching outputs can be connected with signals from external de-
vices, e.g., with PLC signals. In this case, ensure the same potential as well as voltage and
current specifications are defined.
Depending on the firmware version used, the service contacts can be used for various
switching or signaling tasks.
NOTE:
Do not connect the voltage and ground outputs to an external source.
The plug-in screw terminal blocks of the service contacts may be removed or inserted dur-
ing operation of the mGuard.
Control switch CMD
Signal output (digital) ACK
X1 ... X3
US
I1, I2, I3
GND
O1, O2, O3
Voltage output (+)
Supply voltage
Switching input
11
... 36 V DC
Ground output (-)
Supply voltage
Short-circuit-proof
switch output,
maximum 250 mA
at 11 ... 36 V DC
Example
Example
US
I2 GND O2
X2
US
I3 GND O3
X3
US
I1 GND O1
X1
Innominate Security Technologies
I15007_en_02
Service contacts as of firmware version 8.1
Input/CMD I1, CMD I2
Via the web interface under “Management, Service I/O”, you can set whether a push button
or an on/off switch has been connected to the inputs. One or more freely selectable VPN
connections or firewall rule records can be switched via the corresponding switch. A mixture
of VPN connections and firewall rule records is also possible. The web interface displays
which VPN connections and which firewall rule records are connected to this input.
The push button or on/off switch is used to establish and release predefined VPN connec-
tions or the defined firewall rule records.
Operating a connected
push button
•
To switch on the selected VPN connections or firewall rule records, press and hold the
push button for a few seconds and then release the push button.
•
To switch off the selected VPN connections or firewall rule records, press and hold the
push button for a few seconds and then release the push button.
Operating a connected
on/off switch
•
To switch on the selected VPN connections or firewall rule records, set the switch to
ON.
•
To switch off the selected VPN connections or firewall rule records, set the switch to
OFF.
Signal contact (signal out-
put) ACK O1, O2
Via the web interface under “Management,
Service I/O” you can set whether certain VPN
connections or firewall rule records are monitored and displayed via the LED Info
1 (out-
put/ACK O1) or LED Info
2 (output/ACK
O2).
If VPN connections are being monitored, an illuminated Info LED indicates that VPN con-
nections are established.
Alarm output ACK O3
The O3 alarm output monitors the function of the mGuard
rs4000/rs2000 and therefore en-
ables remote diagnostics.
The Fault LED lights up red if the signal output takes low level due to an error (inverted
logic).
The O3 alarm output reports the following when “Management,
Service I/O, Alarm output”
has been activated.
–
Failure of the redundant supply voltage
–
Monitoring of the link status of the Ethernet connections
–
Monitoring of the temperature condition
–
Monitoring of the connection state of the internal modem
Service contacts up to firmware version 8.0
The push button or on/off switch is used to establish and release a predefined VPN connec-
tion.
The output indicates the status of the VPN connection (in the web interface under “IPsec
VPN >> Global >> Options”).
Operating a connected
push button
•
To establish the VPN connection, hold down the button for a few seconds until the INFO
LED flashes. Only then release the button.
Flashing indicates that the mGuard has received the command to establish the VPN
connection and is establishing the VPN connection. As soon as the VPN connection is
established, the INFO LED remains lit continuously.
•
To release the VPN connection, hold down the button for a few seconds until the signal
output flashes or goes out. Only then release the button.
Innominate Security Technologies
59
As soon as the INFO LED goes out, the VPN connection is released.
Operating a connected
on/off switch
•
To establish the VPN connection, set the switch to the ON position.
•
To release the VPN connection, set the switch to the OFF position.
INFO LED
If the INFO LED does not light up, this generally indicates that the defined VPN connection
is not present. Either the VPN connection was not established or it has failed due to an error.
If the INFO LED is illuminated, the VPN connection is present.
If the INFO LED is flashing, the VPN connection is being established or released.
Signal contact (signal out-
put)
The signal contact monitors the function of the mGuard
rs4000/rs2000 and thus enables re-
mote diagnostics.
The FAULT LED lights up red if the signal output takes low level due to an error (inverted
logic).
The voltage at the signal contact corresponds to the supply voltage applied. The following
is reported when monitoring the output voltage:
–
Failure of at least one of the two supply voltages.
–
Power supply of the mGuard
rs4000/rs2000 below the limit value (supply voltage 1
and/or 2 lower than 11
V).
–
Link status monitoring of the Ethernet connections, if configured. By default upon deliv-
ery, the connection is not monitored. Monitoring can be activated (on the web interface
under “Management >> System Settings >> Signal Contact”).
–
Error during selftest.
During a restart, the signal contact is switched off until the mGuard
rs4000/rs2000 has
started up completely. This also applies when the signal contact is manually set to “Closed”
under “Manual settings” in the software configuration.
Innominate Security Technologies
I15007_en_02
3.3.4
Antennas
To establish a mobile communication connection, a matching antenna must be connected
to the devices.
We recommend combined mobile phone GPS antenna with omnidirectional characteristic,
antenna cable with SMA round plug (GSM/UMTS) and R-SMA round plug
(TC
ANT
MOBILE/GPS, 2903590 from Phoenix
Contact).
In the case of the mGuard
rs2000
3G, the WAN is only available via the mobile network,
as a WAN interface is not available. The mobile network function is preset. The
mGuard
rs2000
3G can only be operated in Router mode.
Connecting antennas
Figure
3-5
Antenna connection
•
Connect a suitable antenna to the antenna connection.
Antenna connection
–
SMA for mobile communication (ANT)
–
RSMA (GPS)
•
If the bar graph indicates good or very good reception, affix the antenna (see “Bar
graph” on page
53).
NOTE:
Removing operator permissions
Operation of the wireless system is only permitted with accessories supplied by
Innominate. The use of other accessory components may invalidate the operating li-
cense.
You can find the approved accessories for this wireless system listed with the product at:
www.innominate.com.
GPS
ANT
Innominate Security Technologies
61
3.3.5
SIM card
To establish a mobile communication connection, the mGuard also requires at least one
valid mini SIM card in ID-000 format, via which it assigns and authenticates itself to a mo-
bile network.
The mGuard
rs4000/rs2000
3G can be equipped with two SIM cards. The SIM card in the
SIM
1 slot is the primary SIM card which is normally used to establish the connection. If this
connection fails, the device can optionally turn to the second SIM card in slot SIM
2. You can
set whether, and under which conditions, the connection to the primary SIM card is re-
stored.
The state of the SIM cards is indicated via two LEDs on the front. The LEDs SIM1 and SIM2
light up green when the SIM card is active. If a PIN has not been entered, the LED flashes
green.
Quality of the mobile network connection
The signal strength of the mobile network connection is indicated by three LEDs on the front
of the mGuard
rs4000/rs2000
3G. The LEDs function as a bar graph (refer to “Bar graph” on
page
53).
For stable data transmission, we recommend at least good network reception. If the network
reception is only adequate, only SMS messages can be sent and received.
Inserting the SIM card
You will receive a SIM card from the wireless provider on which all data and services for your
connection are stored. If you use CDMA networks in the USA (e.g., from Verizon Wireless),
you will not receive a SIM card. Change the mGuard
rs4000/rs2000
3G to a CDMA provider
via the web interface.
Figure
3-6
Insert the SIM card
To insert the SIM card, proceed as follows:
•
Press the release button.
•
Remove the SIM card holder.
•
Insert the SIM card so that the SIM chip remains visible.
•
Insert the SIM card holder together with the SIM card into the device until this ends flush
with the housing.
A
B
D
C
Innominate Security Technologies
I15007_en_02
3.3.6
Connecting the supply voltage
The supply voltage is connected via a plug-in screw terminal block, which is located on the
top of the device.
Figure
3-7
Connecting the supply voltage (mGuard
rs4000
3G)
The mGuard
rs4000
3G has a redundant supply voltage. If you only connect one supply
voltage, you will get an error message.
•
Remove the plug-in screw terminal blocks for the power supply and the service con-
tacts.
•
Wire the supply voltage lines of the X4 mGuard screw terminal block. Tighten the
screws on the screw terminal blocks with 0.5
...
0.8
Nm.
•
Insert the plug-in screw terminal blocks into the intended sockets on the top of the
mGuard.
Status LED P1 lights up green when the supply voltage has been connected properly. On
the mGuard
rs4000
3G, the status indicator P2 also lights up if there is a redundant supply
voltage connection.
The mGuard boots the firmware. The Stat LED flashes green. The mGuard is ready for op-
eration as soon as the Ethernet socket LEDs light up. Additionally, the P1/P2 LEDs light up
green and Stat LED flashes green at heartbeat.
Redundant voltage supply (mGuard
rs4000
3G)
A redundant supply voltage can be connected. Both inputs are isolated. The load is not dis-
tributed. With a redundant supply, the power supply unit with the higher output voltage sup-
plies the mGuard
rs4000
3G alone. The supply voltage is electrically isolated from the hous-
ing.
WARNING:
The device is designed for operation with a DC voltage of
11
V DC
...
36
V DC/SELV, 800 mA maximum.
Therefore, only SELV circuits with voltage limitations according to
IEC
60950/EN
60950/VDE 0805 may be connected to the supply connections and the
signal contact.
Table
3-3
Supply voltage mGuard
rs4000/rs2000
3G
mGuard
rs4000
3G
mGuard
rs2000
3G
24V 0V 24V 0V
X4
Innominate Security Technologies
63
If the supply voltage is not redundant, the mGuard
rs4000
3G indicates the failure of the
supply voltage via the signal contact. This message can be prevented by feeding the supply
voltage via both inputs or by installing an appropriate wire jumper between the connections.
Innominate Security Technologies
I15007_en_02
3.4
Preparing the configuration
3.4.1
Connection requirements
–
The mGuard
rs4000/rs2000
3G must be connected to at least one active power sup-
ply unit.
–
For local configuration: The computer that is to be used for configuration must be
connected to the LAN socket on the mGuard.
–
For remote configuration: The mGuard must be configured so that remote configura-
tion is permitted.
–
The mGuard must be connected, i.e.,
the required connections must be working.
3.5
Configuration in Router mode
On initial startup, the mGuard can be accessed via the following address:
–
https://192.168.1.1
3.5.1
IP address 192.168.1.1
To access the configuration interface, it may be necessary to adapt the network configura-
tion of your computer.
Under Windows 7, proceed as follows:
•
In the Control Panel, open the “Network and Sharing Center”.
•
Click on “LAN connection”. (The “LAN connection” item is only displayed if a connection
exists from the LAN interface on the computer to a mGuard in operation or another part-
ner).
•
Click on “Properties”.
•
Select the menu item “Internet protocol Version 4 (TCP/IPv4)”.
•
Click on “Properties”.
•
First select “Use the following IP address” under “Internet Protocol Version 4 Proper-
ties”, then enter the following address, for example:
In Router mode, the mGuard can be accessed via the LAN interface via IP address
192.168.1.1 within network 192.168.1.0/24, if one of the following conditions applies.
–
The mGuard is in the delivery state.
–
The mGuard was reset to the default settings via the web interface and restarted.
–
The rescue procedure (flashing of the mGuard) or the recovery procedure has been
performed.
IP address:
192.168.1.2
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
Depending on the configuration of the mGuard, it may then be necessary to adapt the net-
work interface of the locally connected computer or network accordingly.
Innominate Security Technologies
65
3.6
Establishing a local configuration connection
Web-based administrator
interface
The mGuard is configured via a web browser that is executed on the configuration com-
puter.
The mGuard can be accessed via the following address:
Proceed as follows:
•
Start a web browser.
•
Make sure that the browser, when it is started, does not automatically establish a con-
nection as otherwise the connection establishment to the mGuard may be more diffi-
cult.
In Internet Explorer, make the following settings:
•
In the “Tools” menu, select “Internet Options” and click on the “Connections” tab:
•
Under “Dial-up and Virtual Private Network settings”, select “Never dial a connection”.
•
Enter the address of the mGuard completely into the address line of the web browser
(refer to Table
3-4).
You access the administrator website of the mGuard.
If the administrator web page of the mGuard cannot be accessed
If you have forgotten the
configured address
If the address of the mGuard in Router, PPPoE or PPTP mode has been set to a different
value, and the current address is not known, the mGuard must be reset to the default set-
tings specified above for the IP address using the Recovery procedure (see “Performing a
recovery procedure” on page
69).
If the administrator web
page is not displayed
If the web browser repeatedly reports that the page cannot be displayed, try the following:
•
Disable any active firewalls.
•
Make sure that the browser does not use a proxy server.
In Internet Explorer (Version 8), make the following settings: “Tools” menu, “Internet
Options”, “Connections” tab.
Click on “Properties” under “LAN settings”.
Check that “Use a proxy server for your LAN” (under “Proxy server”) is not activated in
the “Local Area Network (LAN) Settings” dialog box.
•
If other LAN connections are active on the computer, deactivate them until the configu-
ration has been completed.
Under the Windows menu “Start, Settings, Control Panel, Network Connections” or
“Network and Dial-up Connections”, right-click on the corresponding icon and select
“Disable” in the context menu.
After successful connection establishment
Once a connection has been established successfully, a security alert may be displayed.
NOTE:
The web browser used must support SSL encryption (i.e.,
HTTPS).
Table
3-4
Preset address
Default setting
Network mode
Management IP #1
mGuard
rs4000
3G
Router
https://192.168.1.1/
mGuard
rs2000
3G
Router
https://192.168.1.1/
Innominate Security Technologies
I15007_en_02
Explanation:
As administrative tasks can only be performed using encrypted access, a self-signed certif-
icate is supplied with the device.
•
Click “Yes” to acknowledge the security alert.
The login window is displayed.
Figure
3-8
Login
•
To log in, enter the preset user name and password (please note these settings are
case-sensitive):
The mGuard can then be configured via the web interface. For additional information,
please refer to the software reference manual.
User Name:
admin
Password:
mGuard
For security reasons, we recommend you change the default root and administrator pass-
words during initial configuration.
Innominate Security Technologies
67
3.7
Remote configuration
Requirement
The mGuard must be configured so that remote configuration is permitted.
The option for remote configuration is disabled by default.
Switch on the remote configuration option in the web interface under “Management >> Web
Settings”.
How to proceed
To configure the mGuard via its web user interface from a remote computer, establish the
connection to the mGuard from there.
Proceed as follows:
•
Start the web browser on the remote computer.
•
Under address, enter the IP address where the mGuard can be accessed externally
over the Internet or WAN, together with the port number (if required).
Example
If the mGuard can be accessed over the Internet, for example, via address
https://123.45.67.89/ and port number 443 has been specified for remote access, the fol-
lowing address must be entered in the web browser of the remote peer:
https://123.45.67.89/
If a different port number is used, it should be entered after the IP address, e.g.,
https://123.45.67.89:442/
Configuration
The mGuard can then be configured via the web interface.
For additional information,
please refer to the software reference manual.
Innominate Security Technologies
I15007_en_02
3.8
Restart, recovery procedure, and flashing the firm-
ware
The Reset button is used to set the device to one of the following states:
–
Performing a restart
–
Performing a recovery procedure
–
Flashing the firmware/rescue procedure
Figure
3-9
Reset button
3.8.1
Performing a restart
Objective
The device is restarted with the configured settings.
Action
•
Press the Reset button for around 1.5 seconds until the Err LED lights up.
(Alternatively, disconnect the power supply and then connect it again.)
Reset button
Innominate Security Technologies
69
3.8.2
Performing a recovery procedure
Objective
The network configuration (but not the rest of the configuration) is to be reset to the delivery
state, as it is no longer possible to access the mGuard.
When performing the recovery procedure, the default settings are established:
The mGuard is reset to router mode with the fixed IP address.
–
The CIFS integrity monitoring function is also disabled because this only works when
the management IP is active.
–
In addition, MAU management is switched on for Ethernet connections. HTTPS access
is enabled via the local Ethernet connection (LAN).
–
The settings configured for VPN connections and the firewall are retained, including
passwords.
Possible reasons for performing the recovery procedure:
–
The mGuard is in Router or PPPoE mode.
–
The configured device address of the mGuard differs from the default setting.
–
The current IP address of the device is not known.
Action
•
Slowly press the Reset button six times.
After approximately two seconds, the Stat LED lights up green.
•
When the Stat LED has gone out, slowly press the Reset button again six times.
If successful, the Stat LED lights up green.
If unsuccessful, the Err LED lights up red.
If successful, the device restarts after two seconds and switches to Router mode. The de-
vice can then be reached again under the corresponding address.
Table
3-5
Preset address
Default setting
Network mode
Management IP #1
mGuard
rs4000
3G
Router
https://192.168.1.1/
mGuard
rs2000
3G
Router
https://192.168.1.1/
Up-to-date information on the recovery and flashing procedure can be found in the appli-
cation note for your mGuard firmware version.
You can find application notes under the following Internet address:
www.innominate.com.
Innominate Security Technologies
I15007_en_02
3.8.3
Flashing the firmware/rescue procedure
Objective
The entire firmware of the mGuard should be reloaded on the device.
–
All configured settings are deleted. The mGuard is set to the delivery state.
Possible reasons
The administrator and root password have been lost.
Requirements
Requirements for flashing
–
The mGuard firmware has been obtained from your dealer's support team or the
www.innominate.com website and has been saved on a compatible SD card.
–
This SD card has been inserted into the mGuard.
–
The relevant firmware files are available for download from the download page of
www.innominate.com. The files must be located under the following path names or in
the following folders on the SD card:
Firmware/install-ubi.mpc83xx.p7s
Firmware/ubifs.img.mpc83xx.p7s
NOTE:
During flashing, the firmware is always loaded from an SD card first. The firmware
is only loaded from a TFTP server if no SD card is found.
The following requirements apply when loading the firmware from an SD card:
–
All necessary firmware files must be located in a common directory on the first parti-
tion of the SD card
–
This partition must use a VFAT file system (standard type for SD cards).
To flash the firmware from a TFTP server, a TFTP server must be installed on the locally
connected computer (see “Installing the DHCP and TFTP server” on page
258).
NOTE:
Installing a second DHCP server in a network could affect the configuration of the
entire network.
Innominate Security Technologies
71
Action
To flash the firmware or to perform the rescue procedure, proceed as follows:
•
Hold down the Reset button until the Stat, Mod, and Sig LEDs light up green. Then, the
mGuard is in the recovery state.
•
Release the Reset button within a second of entering the recovery state.
If the Reset button is not released, the mGuard is restarted.
The mGuard now starts the rescue system: It searches for a DHCP server via the LAN
interface in order to obtain an IP address. (Exception: if an SD card is inserted into the
device with corresponding firmware, the rescue system is started from there).
The Stat LED flashes.
The “install.p7s” file is loaded from the TFTP server or SD card. It contains the electron-
ically signed control procedure for the installation process. Only files that are signed are
executed.
The control procedure deletes the current contents of the Flash memory and prepares
for a new firmware installation.
The Stat, Mod, and Sig LEDs form a running light.
The “jffs2.img.p7s” firmware file is downloaded from the TFTP server or SD card and
written to the Flash memory. This file contains the actual mGuard operating system and
is signed electronically. Only files signed by Innominate are accepted.
This process takes around 3 to 5 minutes. The Stat LED is lit continuously.
The new firmware is extracted and configured. This procedure takes 1 to 3 minutes.
As soon as the procedure is complete, the Stat, Mod, and Sig LEDs flash green simultane-
ously.
•
Restart the mGuard. To do so, press the Reset button.
(Alternatively, disconnect the power supply and then connect it again.)
The mGuard is in the delivery state. You can now configure it again (see “Establishing a
local configuration connection” on page
65):
NOTE:
Do not interrupt the power supply to the mGuard during any stage of the flashing
procedure. Otherwise, the device could be damaged and may have to be reactivated by
the manufacturer.
Innominate Security Technologies
I15007_en_02
3.9
Technical data
Hardware properties
mGuard
rs4000
3G
mGuard
rs2000
3G
Platform
Freescale network processor
Freescale network processor
Network interfaces
4 LAN Ports (managed) | 1 DMZ port |
1 WAN port
Ethernet IEEE 802.3 10/100-BaseTX
RJ45 | full duplex | auto MDIX
4 LAN ports (unmanaged)
Ethernet
IEEE
802.3
10/100-BaseTX
RJ45 | full duplex | auto MDIX
Wireless interface
WAN | GSM | GPRS | EDGE | UMTS |
CDMA2000
WAN | GSM | GPRS | EDGE | UMTS |
CDMA2000
SIM interfaces (1 + 2)
1.8 V | 3 V, redundant
1.8 V | 3 V, redundant
Data rate
≤ 14.4 Mbps (HSDPA)
≤ 14.4 Mbps (HSDPA)
Other interfaces
Serial RS-232 | D-SUB 9 connector
3 digital inputs and 3 digital outputs
Serial RS-232 | D-SUB 9 connector
3 digital inputs and 3 digital outputs
Memory
128 MB RAM | 128 MB Flash | SD card
Replaceable configuration memory
128 MB RAM | 128 MB Flash | SD card
Replaceable configuration memory
Redundancy options
Optional: VPN | router and firewall
–
Power supply
Voltage range 11 ... 36 V DC, redundant
Voltage range 11 ... 36 V DC, redundant
Power consumption
typical < 200 mA (24 V DC) |
maximum < 800 mA (10 V DC)
typical < 200 mA (24 V DC) |
maximum < 800 mA (10 V DC)
Humidity range
5% ... 95% (operation, storage), non-con-
densing
5% ... 95% (operation, storage), non-con-
densing
Degree of protection
IP20
IP20
Temperature range
-40°C ... +60°C (operation)
-40°C ... +70°C (storage)
-40°C ... +60°C (operation)
-40°C ... +70°C (storage)
Dimensions (H x W x D)
130 x 45 x 114 mm (up to DIN rail support)
130 x 45 x 114 mm (up to DIN rail support)
Weight
850 g
835 g
Firmware and power values
mGuard
rs4000
3G
mGuard
rs2000
3G
Firmware compatibility
For mGuard v8.0 or later: Innominate recommends the use of the latest firmware ver-
sion and patch releases in each case.
For the scope of functions, please refer to the relevant firmware data sheet.
Data throughput (router | firewall)
Router mode, default firewall rules, bidirectional throughput: 99 Mbps, maximum
Stealth mode, default firewall rules, bidirectional throughput: 50 Mbps, maximum
When using the DMZ as independent network zone, the maximum possible data
throughput is distributed to the three zones.
Virtual Private Network (VPN)
IPsec (IETF standard)
Up to 250 VPN tunnels
IPsec (IETF standard)
Up to 2 VPN tunnels
Hardware-based encryption
DES | 3DES | AES-128/192/256
DES | 3DES | AES-128/192/256
Encrypted VPN throughput (AES-256)
Router mode, default firewall rules, bidirectional throughput: 35
Mbps, maximum
Stealth mode, default firewall rules, bidirectional throughput: 25
Mbps, maximum
When using the DMZ as independent network zone, the maximum possible data
throughput is distributed to the three zones.
Data throughput (mobile)
Depending on the mobile connection
≤ 14,4 Mbit/s (HSDPA) upload
≤ 5,7 Mbit/s (HSDPA) download
Management support
Web GUI (HTTPS) | command line interface (SSH) | SNMP v1/2/3 | central device man-
agement software
Diagnostics
13 LEDs (Power 1 + 2, State, Error, Signal, Fault, Modem, Info, Signal Status, SIM Sta-
tus) | Service I/O| Log File | Remote Syslog
Innominate Security Technologies
73
Other
mGuard
rs4000
3G
mGuard
rs2000
3G
Conformance
CE | FCC | UL 508 | electrical isolation (VCC//PE) | ANSI / ISA 12.12 Class I Div.
2
Special features
GPS / GLONASS receiver | realtime clock | Trusted Platform Module (TPM) | tempera-
ture sensor | mGuard Secure Cloud ready
Innominate Security Technologies
75
4
mGuard
delta²
Table
4-1
Available mGuard
delta² versions
The mGuard
delta² is ideal for use in desktop applications, in distribution compartments,
and other environments close to production processes with low requirements for industrial
hardening.
Individual devices or network segments can be safely networked and comprehensively pro-
tected. The mGuard
delta² can be used as a firewall between office and production net-
works as well as a security router for small and medium-sized workgroups.
Figure
4-1
mGuard
delta²
Available versions
Order No.
mGuard delta² TX/TX
HW-103060
mGuard delta² TX/TX VPN
BD-211010
Innominate Security Technologies
I15007_en_02
4.1
Operating elements and LEDs
SD card slot (configuration
memory)
RJ45 socket (LAN 1)
for connecting to the in-
ternal network
RJ45 socket (WAN 1)
for connecting to the ex-
ternal network
Reset button
LEDs
LAN
2/WAN 2
LEDs
LAN
1/WAN 1
LEDs
Figure
4-2
Operating elements and LEDs on the
Table
4-2
LEDs on the mGuard
delta²
LEDs
State
Meaning
WAN 1
LAN 1
Green
On
Full duplex
Off
Half duplex
WAN 2
LAN 2
Yellow
On
10 Mbps
Flash-
ing
10 Mbps, data transmission active
Green
On
100 Mbps
Flash-
ing
100 Mbps, data transmission active
PWR
Green
On
Supply voltage OK
STAT
Green
Flash-
ing
The mGuard is ready to operate.
ERR
Red
On
System error
FAULT
Red
On
mGuard in the booting or flashing state
INFO
Not used
Innominate Security Technologies
77
4.2
Startup
4.2.1
Safety notes
To ensure correct operation and the safety of the environment and of personnel, the
mGuard must be installed, operated, and maintained correctly.
General notes regarding usage
4.2.2
Checking the scope of supply
Before startup, check the scope of supply to ensure nothing is missing.
The scope of supply includes:
–
mGuard
delta²
–
Package slip
–
12 V DC power supply including different country adapters
NOTE:
Risk of material damage due to incorrect wiring
Only connect the mGuard network ports to LAN installations. Some telecommunications
connections also use RJ45 sockets; these must not be connected to the RJ45 sockets of
the mGuard.
NOTE:
Select suitable ambient conditions
–
Ambient temperature:
0°C
...
+40°C
–
Maximum humidity, non-condensing:
5%
...
95%
To avoid overheating, do not expose the mGuard to direct sunlight or other heat
sources.
NOTE:
Cleaning
Clean the device housing with a soft cloth. Do not use aggressive solvents.
Innominate Security Technologies
I15007_en_02
4.3
Connecting the mGuard
delta²
4.3.1
Connecting to the network
•
Connect the mGuard to the network. To do this, you need a suitable UTP cable (CAT5)
which is not included in the scope of supply.
•
Connect the internal network interface LAN 1 of the mGuard to the corresponding
Ethernet network card of the configuration computer or a valid network connection of
the internal network (LAN).
4.3.2
Connecting the supply voltage
•
Connect the wide-range power supply unit of the mGuard to a suitable power supply.
Connect the low-voltage plug of the power supply unit on the back of the mGuard.
Figure
4-3
Low-voltage plug of the power supply unit
The status LED PWR lights up green when the supply voltage has been connected properly.
The mGuard boots the firmware. Status LED STAT flashes green.
The mGuard is ready for operation as soon as the LAN/WAN LEDs of the Ethernet socket
light up.
Additionally, the status LED PWR lights up green and the status LED STAT flashes green
at heartbeat.
NOTE:
Notes on mounting and installation
Only connect the RJ45 Ethernet ports of the mGuard to matching network installations.
Some telecommunications connections also use RJ45 sockets. You may not connect
these to the RJ45 ports of the mGuard.
Safe isolation of live circuits is only guaranteed if connected devices fulfill requirements
specified by VDE 0106-101 (safe isolation). The supply lines must be isolated or laid sep-
arately to live circuits.
Innominate Security Technologies
79
4.4
Preparing the configuration
4.4.1
Connection requirements
mGuard
delta²
–
The mGuard
delta² must be connected to its power supply.
–
For local configuration: The computer that is to be used for configuration must be
connected to the LAN socket on the mGuard.
–
For remote configuration: The mGuard must be configured so that remote configura-
tion is permitted.
–
The mGuard must be connected, i.e.,
the required connections must be working.
4.4.2
Local configuration on startup (EIS)
As of firmware version 7.2, initial startup of mGuard products provided in Stealth mode is
considerably easier. From this version onwards, the EIS (Easy Initial Setup) procedure en-
ables startup to be performed via preset or user-defined management addresses without
actually having to connect to an external network.
The mGuard is configured using a web browser on the computer used for configuration.
According to the default setting, the mGuard can be accessed via the following addresses:
The mGuard is preset to the “multiple Clients” stealth configuration. You need to configure
a management
IP address and default gateway if you want to use VPN connections (in the
web interface under “Network >> Interfaces >> General”). Alternatively, you can select a dif-
ferent stealth configuration or use another network mode.
NOTE:
The web browser used must support SSL encryption (i.e.,
HTTPS).
Table
4-3
Preset addresses
Default setting
Network
mode
Management IP #1
Management IP #2
mGuard
delta²
Stealth
https://1.1.1.1/
https://192.168.1.1/
Innominate Security Technologies
I15007_en_02
4.5
Configuration in Stealth mode
On initial startup, the mGuard can be accessed via two addresses:
–
https://192.168.1.1/ (see Page
81)
–
https://1.1.1.1/ (see Page
81)
Alternatively, an IP address can be assigned via BootP (see “Assigning the IP address via
BootP” on page
82).
The mGuard can be accessed via https://192.168.1.1/ if the external network interface is not
connected on startup.
Computers can access the mGuard via https://1.1.1.1/ if they are directly or indirectly con-
nected to the LAN port of the mGuard. For this purpose, the mGuard with LAN port and
WAN port must be integrated in an operational network in which the default gateway can be
accessed via the WAN port.
–
After access via IP address 192.168.1.1 and successful login, IP address
192.168.1.1 is set as a fixed management
IP address.
–
After access via IP address 1.1.1.1 or after IP address assignment via BootP, the FL
MGUARD can no longer be accessed via IP address 192.168.1.1.
Innominate Security Technologies
81
4.5.1
IP address 192.168.1.1
To access the configuration interface, it may be necessary to adapt the network configura-
tion of your computer.
Under Windows 7, proceed as follows:
•
In the Control Panel, open the “Network and Sharing Center”.
•
Click on “LAN connection”. (The “LAN connection” item is only displayed if a connection
exists from the LAN interface on the computer to a mGuard in operation or another part-
ner).
•
Click on “Properties”.
•
Select the menu item “Internet protocol Version 4 (TCP/IPv4)”.
•
Click on “Properties”.
•
First select “Use the following IP address” under “Internet Protocol Version 4 Proper-
ties”, then enter the following address, for example:
4.5.2
IP address https://1.1.1.1/
With a configured network
interface
In order for the mGuard to be addressed via address https://1.1.1.1/, it must be connected
to a configured network interface. This is the case if it is connected in an existing network
connection and if the default gateway can be accessed via the WAN port of the mGuard at
the same time.
In this case, the web browser establishes a connection to the mGuard configuration inter-
face after the address https://1.1.1.1/ is entered (see “Establishing a local configuration con-
nection” on page
83). Continue from this point.
In Stealth mode, the mGuard can be accessed via the LAN interface via IP address
192.168.1.1 within network 192.168.1.0/24, if one of the following conditions applies.
–
The mGuard is in the delivery state.
–
The mGuard was reset to the default settings via the web interface and restarted.
–
The rescue procedure (flashing of the mGuard) or the recovery procedure has been
performed.
IP address:
192.168.1.2
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
Depending on the configuration of the mGuard, it may then be necessary to adapt the net-
work interface of the locally connected computer or network accordingly.
After access via IP address 1.1.1.1, the FL MGUARD can no longer be accessed via IP
address 192.168.1.1
Innominate Security Technologies
I15007_en_02
4.5.3
Assigning the IP address via BootP
For IP address assignment, the mGuard uses the BootP protocol. The IP address can also
be assigned via BootP. On the Internet, numerous BootP servers are available. You can use
any of these programs for address assignment.
Section 14.1 explains IP address assignment using the free Windows software
“IP
Assignment
Tool” (IPAssign.exe).
Notes for BootP
During initial startup, the mGuard transmits BootP requests without interruption until it re-
ceives a valid IP address. After receiving a valid IP address, the mGuard no longer sends
BootP requests. The FL MGUARD can then no longer be accessed via IP address
192.168.1.1.
After receiving a BootP reply, the mGuard no longer sends BootP requests, not even after
it has been restarted. For the mGuard to send BootP requests again, it must either be set to
the default settings or one of the procedures (recovery or flash) must be performed.
Requirements
The mGuard is connected to a computer using a Microsoft Windows operating system.
After assigning an IP address via BootP, the FL MGUARD can no longer be accessed via
IP address 192.168.1.1
Innominate Security Technologies
83
4.6
Establishing a local configuration connection
Web-based administrator
interface
The mGuard is configured via a web browser that is executed on the configuration com-
puter.
The mGuard can be accessed via one of the following addresses:
Proceed as follows:
•
Start a web browser.
•
Make sure that the browser, when it is started, does not automatically establish a con-
nection as otherwise the connection establishment to the mGuard may be more diffi-
cult.
In Internet Explorer, make the following settings:
•
In the “Tools” menu, select “Internet Options” and click on the “Connections” tab:
•
Under “Dial-up and Virtual Private Network settings”, select “Never dial a connection”.
•
Enter the address of the mGuard completely into the address line of the web browser
(refer to Table
4-4).
You access the administrator website of the mGuard.
If the administrator web page of the mGuard cannot be accessed
If you have forgotten the
configured address
If the address of the mGuard in Router, PPPoE or PPTP mode has been set to a different
value, and the current address is not known, the mGuard must be reset to the default set-
tings specified above for the IP address using the Recovery procedure (see “Performing a
recovery procedure” on page
87).
If the administrator web
page is not displayed
If the web browser repeatedly reports that the page cannot be displayed, try the following:
•
Check whether the default gateway of the connected configuration computer is initial-
ized (see “Local configuration on startup (EIS)” on page
79).
•
Disable any active firewalls.
•
Make sure that the browser does not use a proxy server.
In Internet Explorer (Version 8), make the following settings: “Tools” menu, “Internet
Options”, “Connections” tab.
Click on “Properties” under “LAN settings”.
Check that “Use a proxy server for your LAN” (under “Proxy server”) is not activated in
the “Local Area Network (LAN) Settings” dialog box.
•
If other LAN connections are active on the computer, deactivate them until the configu-
ration has been completed.
Under the Windows menu “Start, Settings, Control Panel, Network Connections” or
“Network and Dial-up Connections”, right-click on the corresponding icon and select
“Disable” in the context menu.
NOTE:
The web browser used must support SSL encryption (i.e.,
HTTPS).
Table
4-4
Preset addresses
Default setting
Network
mode
Management IP #1
Management IP #2
mGuard
delta²
Stealth
https://1.1.1.1/
https://192.168.1.1/
Innominate Security Technologies
I15007_en_02
After successful connection establishment
Once a connection has been established successfully, a security alert may be displayed.
Explanation:
As administrative tasks can only be performed using encrypted access, a self-signed certif-
icate is supplied with the device.
•
Click “Yes” to acknowledge the security alert.
The login window is displayed.
Figure
4-4
Login
•
To log in, enter the preset user name and password (please note these settings are
case-sensitive):
The mGuard can then be configured via the web interface.
For additional information,
please refer to the software reference manual.
User Name:
admin
Password:
mGuard
For security reasons, we recommend you change the default root and administrator pass-
words during initial configuration.
Innominate Security Technologies
85
4.7
Remote configuration
Requirement
The mGuard must be configured so that remote configuration is permitted.
The option for remote configuration is disabled by default.
Switch on the remote configuration option in the web interface under “Management >> Web
Settings”.
How to proceed
To configure the mGuard via its web user interface from a remote computer, establish the
connection to the mGuard from there.
Proceed as follows:
•
Start the web browser on the remote computer.
•
Under address, enter the IP address where the mGuard can be accessed externally
over the Internet or WAN, together with the port number (if required).
Example
If the mGuard can be accessed over the Internet, for example, via address
https://123.45.67.89/ and port number 443 has been specified for remote access, the fol-
lowing address must be entered in the web browser of the remote peer:
https://123.45.67.89/
If a different port number is used, it should be entered after the IP address, e.g.,
https://123.45.67.89:442/
Configuration
The mGuard can then be configured via the web interface.
For additional information,
please refer to the software reference manual.
Innominate Security Technologies
I15007_en_02
4.8
Restart, recovery procedure, and flashing the firm-
ware
The Reset button is used to set the device to one of the following states:
–
Performing a restart
–
Performing a recovery procedure
–
Flashing the firmware/rescue procedure
Figure
4-5
Reset button
4.8.1
Performing a restart
Objective
The device is restarted with the configured settings.
Action
•
Press the Reset button for around 1.5 seconds until the ERR LED lights up.
(Alternatively, disconnect the power supply and then connect it again.)
Reset button
Innominate Security Technologies
87
4.8.2
Performing a recovery procedure
Objective
The network configuration (but not the rest of the configuration) is to be reset to the delivery
state, as it is no longer possible to access the mGuard.
When performing the recovery procedure, the default settings are established:
The mGuard is reset to Stealth mode with the default setting “multiple Clients”.
–
The CIFS integrity monitoring function is also disabled because this only works when
the management IP is active.
–
In addition, MAU management is switched on for Ethernet connections. HTTPS access
is enabled via the local Ethernet connection (LAN).
–
The settings configured for VPN connections and the firewall are retained, including
passwords.
Possible reasons for performing the recovery procedure:
–
The mGuard is in Router or PPPoE mode.
–
The configured device address of the mGuard differs from the default setting.
–
The current IP address of the device is not known.
Action
•
Slowly press the Reset button six times.
After approximately 2 seconds, the STAT LED lights up green.
•
Slowly press the Reset button again six times.
If successful, the STAT LED lights up green.
If unsuccessful, the ERR LED lights up red.
If successful, the device restarts after two seconds and switches to Stealth mode. The de-
vice can then be reached again under the corresponding addresses.
Table
4-5
Preset addresses
Default setting
Network
mode
Management IP #1
Management IP #2
mGuard
delta²
Stealth
https://1.1.1.1/
https://192.168.1.1/
Up-to-date information on the recovery and flashing procedure can be found in the appli-
cation note for your mGuard firmware version.
You can find application notes under the following Internet address:
www.innominate.com.
Innominate Security Technologies
I15007_en_02
4.8.3
Flashing the firmware/rescue procedure
Objective
The entire firmware of the mGuard should be reloaded on the device.
–
All configured settings are deleted. The mGuard is set to the delivery state.
–
In Version 5.0.0 or later of the mGuard, the licenses installed on the mGuard are re-
tained after flashing the firmware. Therefore, they do not have to be installed again.
Possible reasons
The administrator and root password have been lost.
Requirements
Requirements for flashing
–
The mGuard firmware has been obtained from your dealer's support team or the
www.innominate.com website and has been saved on a compatible SD card.
–
This SD card has been inserted into the mGuard.
–
The relevant firmware files are available for download from the download page of
www.innominate.com. The files must be located under the following path names or in
the following folders on the SD card:
Firmware/install-ubi.mpc83xx.p7s
Firmware/ubifs.img.mpc83xx.p7s
NOTE:
During flashing, the firmware is always loaded from an SD card first. The firmware
is only loaded from a TFTP server if no SD card is found.
The following requirements apply when loading the firmware from an SD card:
–
All necessary firmware files must be located in a common directory on the first parti-
tion of the SD card.
–
This partition must use a VFAT file system (standard type for SD cards).
To flash the firmware from a TFTP server, a TFTP server must be installed on the locally
connected computer (see “Installing the DHCP and TFTP server” on page
258).
NOTE:
Installing a second DHCP server in a network could affect the configuration of the
entire network.
Innominate Security Technologies
89
Action
To flash the firmware or to perform the rescue procedure, proceed as follows:
•
Hold down the Reset button until the STAT, MOD, and SIG LEDs light up green. Then,
the mGuard is in the recovery state.
•
Release the Reset button within a second of entering the recovery state.
If the Reset button is not released, the mGuard is restarted.
The mGuard now starts the recovery system: It searches for a DHCP server via the LAN
interface in order to obtain an IP address.
The STAT LED flashes.
The “install.p7s” file is loaded from the TFTP server or SD card. It contains the electron-
ically signed control procedure for the installation process. Only files that are signed are
executed.
The control procedure deletes the current contents of the Flash memory and prepares
for a new firmware installation.
The STAT, MOD, and SIG LEDs form a running light.
The “jffs2.img.p7s” firmware file is downloaded from the TFTP server or SD card and
written to the Flash memory. This file contains the actual mGuard operating system and
is signed electronically. Only files signed by Innominate are accepted.
This process takes around 3 to 5 minutes. The STAT LED is lit continuously.
The new firmware is extracted and configured. This procedure takes 1 to 3 minutes.
As soon as the procedure is complete, the STAT, MOD, and SIG LEDs flash green simulta-
neously.
•
Restart the mGuard. To do this, briefly press the Reset button.
(Alternatively, disconnect the power supply and then connect it again.)
The mGuard is in the delivery state. You can now configure it again (see “Establishing a
local configuration connection” on page
83):
NOTE:
Do not interrupt the power supply to the mGuard during any stage of the flashing
procedure. Otherwise, the device could be damaged and may have to be reactivated by
the manufacturer.
Innominate Security Technologies
I15007_en_02
4.9
Technical data
Hardware properties
Platform
Freescale network processor
with 330
MHz clocking
Network interfaces
1 LAN port | 1 WAN port
Ethernet IEEE 802.3 10/100 Base TX |
RJ45 | full duplex | auto MDIX
Other interfaces
Serial RS-232, D-SUB 9 connector
Memory
128 MB RAM | 128 MB Flash
SD card, replaceable configuration memory
Redundancy options
Optional: VPN | router
Power supply
External power supply unit 12 V/0.85 A DC | 100 – 240 V/0.4 A AC
Power consumption
2.13 W, typical
Humidity range
5% ... 95% during operation, non-condensing
Degree of protection
IP20
Temperature range
0°C ... +40°C (operation)
0°C ... +60°C (storage)
Dimensions (H x W x D)
45 x 130 x 114 mm
Weight
629 g
Firmware and power values
Firmware compatibility
For mGuard v7.4.0 or later: Innominate recommends the use of the latest
firmware version and patch releases in each case.
For the scope of functions, please refer to the relevant firmware data sheet.
Data throughput (router | firewall)
Router mode, default firewall rules, bidirectional throughput: max. 99 Mbps
Stealth mode, default firewall rules, bidirectional throughput: max. 50 Mbps
Virtual Private Network (VPN)
IPsec (IETF standard), VPN models up to 10
tunnels,
Optionally up to 250 VPN tunnels
Hardware-based encryption
DES | 3DES | AES-128/192/256
Encrypted VPN throughput (AES-256)
Router mode, default firewall rules, bidirectional throughput: max. 35 Mbps
Stealth mode, default firewall rules, bidirectional throughput: max. 25 Mbps
Management support
Web GUI (HTTPS) | command line interface (SSH) | SNMP v1/2/3 | central
device management software
Diagnostics
LEDs (Power, State, Error, Signal, Fault, Info) | log file | remote syslog
Other
Conformance
CE | FCC
Special features
Realtime clock | Trusted Platform Module (TPM) | temperature sensor |
mGuard Remote
Services Portal ready
Innominate Security Technologies
91
5
mGuard
pci²
SD
Table
5-1
Available mGuard
pci²
SD versions
The mGuard
pci²
SD has the design of a PCI-compatible plug-in board. It is available in two
versions:
–
mGuard
pci²
SD for devices or machines with PCI bus
–
mGuard
pcie²
SD for devices or machines with PCI Express bus
To aid understanding, mGuard
pci²
SD is used for the two device versions in this user man-
ual.
The mGuard
pci²
SD is suitable for distributed protection of industrial and panel PCs, indi-
vidual machines or industrial robots. It has a configuration memory in the form of a replace-
able SD card, which can be easily accessed on the front.
Figure
5-1
mGuard
pci²
SD
Available versions
Order No.
mGuard pci² SD
HW-102061
mGuard pcie² SD
HW-102071
mGuard pci² SD VPN
BD-111040
mGuard pcie² SD VPN
BD-111060
Innominate Security Technologies
I15007_en_02
5.1
Operating elements and LEDs
WAN 1 LED
SD card slot (configuration
memory)
Reset button
RJ45 socket (LAN 1) for
connecting to the internal
network
RJ45 socket (WAN 1) for
connecting to the external
network/Internet
LAN 1 LED
Battery (can be replaced)
Extension connection (LEDs, Reset button, SD card)
STAT LED
LAN 2 LED
WAN 1 LED
Figure
5-2
Operating elements and LEDs on the mGuard
pci²
SD
Table
5-2
LEDs on the mGuard
pci²
SD
LEDs
State
Meaning
WAN 1
LAN 1
Green
On
Full duplex
Off
Half duplex
WAN 2
LAN 2
Yellow
On
10 Mbps
Flash-
ing
10 Mbps, data transmission active
Green
On
100 Mbps
Flash-
ing
100 Mbps, data transmission active
LAN 1
LAN 2
WAN 1
Various LED light
codes
Recovery procedure/flashing
See “Restart, recovery procedure, and flashing the firmware” on page
104.
STAT
Red/green
Flash-
ing
Boot process. When the device has just been connected to the power supply. After a few
seconds, this LED changes to the heartbeat state.
Green
Flash-
ing
Heartbeat. The mGuard is connected correctly and ready to operate.
Red
Flash-
ing
System error. Restart the device.
•
Press the Reset button (for 1.5 seconds).
•
Alternatively, briefly disconnect the device power supply and then connect it again.
If the error is still present, start the recovery procedure (see “Performing a recovery proce-
dure” on page
105) or contact your dealer.
Innominate Security Technologies
93
5.2
Startup
5.2.1
Safety notes
To ensure correct operation and the safety of the environment and of personnel, the
mGuard must be installed, operated, and maintained correctly.
General notes regarding usage
5.2.2
Checking the scope of supply
Before startup, check the scope of supply to ensure nothing is missing.
The scope of supply includes:
–
mGuard
pci²
SD
–
Package slip
NOTE:
Risk of material damage due to incorrect wiring
Only connect the mGuard network ports to LAN installations. Some telecommunications
connections also use RJ45 sockets; these must not be connected to the RJ45 sockets of
the mGuard.
NOTE:
Connection notes
–
A free PCI slot (3.3
V or 5
V) must be available on your PC when using the
mGuard
pci²
SD.
–
Do not bend connecting cables. Only use the network plug for connection to a net-
work.
NOTE:
Select suitable ambient conditions
–
Ambient temperature:
0°C
...
+60°C (mGuard
pci²
SD with battery)
0°C
...
+70°C (mGuard
pci²
SD without battery)
–
Maximum humidity, non-condensing:
5%
...
95%
To avoid overheating, do not expose the mGuard to direct sunlight or other heat sources.
NOTE:
Cleaning
Clean the device housing with a soft cloth. Do not use aggressive solvents.
Innominate Security Technologies
I15007_en_02
5.3
Installation of mGuard
pci²
SD
5.3.1
Installing the hardware
mGuard
pci²
SD: structure
Figure
5-3
mGuard
pci²
SD structure
•
Install the mGuard
pci²
SD in a free PCI or PCI Express slot. Observe the notes in the
documentation for your system.
WARNING:
This is a Class A item of equipment. This equipment can cause radio interfer-
ence in residential areas; in this case, the operator may be required to implement appro-
priate measures.
WARNING:
Safe isolation of live circuits is only guaranteed if connected devices fulfill re-
quirements specified by VDE 0106-101 (safe isolation). The supply lines must be isolated
or laid separately to live circuits.
NOTE:
Electrostatic discharge
Before installation, touch the metal frame of the PC in which the mGuard
pci²
SD is to be
installed, in order to remove electrostatic discharge.
The device contains components that can be damaged or destroyed by electrostatic dis-
charge. When handling the device, observe the necessary safety precautions against
electrostatic discharge (ESD) according to EN 61340-5-1 and IEC 61340-5-1.
SD card slot (configuration
memory)
Reset button
RJ45 socket (LAN 1) for connecting to the in-
ternal network
Use a UTP cable (CAT5). The cable is not
supplied as standard.
RJ45 socket (WAN 1) for connecting to the
external network/Internet.
Use a UTP cable (CAT5). The cable is not
supplied as standard.
Battery (can be replaced)
Extension connection (LEDs, Reset button, SD card)
Innominate Security Technologies
95
5.4
Preparing the configuration
5.4.1
Connection requirements
–
For local configuration: The computer used for configuration must meet the following
requirements:
–
The computer must be connected to the mGuard LAN connection or to the mGuard
via the local network.
–
For remote configuration: The mGuard must be configured so that remote configura-
tion is permitted.
–
The mGuard must be connected, i.e.,
the required connections must be working.
5.4.2
Local configuration on startup (EIS)
As of firmware version 7.2, initial startup of mGuard products provided in Stealth mode is
considerably easier. From this version onwards, the EIS (Easy Initial Setup) procedure en-
ables startup to be performed via preset or user-defined management addresses without
actually having to connect to an external network.
The mGuard is configured using a web browser on the computer used for configuration.
According to the default setting, the mGuard can be accessed via the following addresses:
The mGuard is preset to the “multiple Clients” stealth configuration. You need to configure
a management
IP address and default gateway if you want to use VPN connections (see
Page
101). Alternatively, you can select a different stealth configuration or use another net-
work mode.
NOTE:
The web browser used must support SSL encryption (i.e.,
HTTPS).
Table
5-3
Preset addresses
Default setting
Network
mode
Management IP #1
Management IP #2
mGuard
pci²
SD
Stealth
https://1.1.1.1/
https://192.168.1.1/
Innominate Security Technologies
I15007_en_02
5.5
Configuration in Stealth mode
The mGuard
pci²
SD can be started up in three different ways:
–
Start up the device in Stealth mode (standard)
–
Start up the device via temporary management IP address
–
Start up device via BootP
5.5.1
Start up the device in Stealth mode (standard)
Insert the mGuard
pci²
SD between an existing network connection.
To connect to the LAN and WAN interfaces, a suitable UTP cable (CAT5) is required. The
cables are not supplied as standard.
•
Connect the internal network interface (LAN 1) of the mGuard
pci²
SD to the corre-
sponding Ethernet network card of the configuration computer or a valid network con-
nection of the internal network.
•
Connect the external network interface (WAN 1) of the mGuard
pci²
SD to the external
network, e.g., Internet.
The STAT status LED lights up green when the supply voltage has been connected prop-
erly.
The mGuard boots the firmware. The STAT status LED flashes green during this time.
The mGuard is ready for operation as soon as the lower Ethernet socket LEDs light up. In
addition, the STAT status LED flashes green at heartbeat.
The mGuard is configured via a web browser that is executed on the locally connected com-
puter.
The mGuard is preset and can be accessed via address https://1.1.1.1/
If the lower LEDs in the Ethernet sockets do not light up, this indicates a missing connec-
tion to the internal or external network. If no LED lights up, the supply voltage is missing.
NOTE:
The web browser used must support SSL encryption (i.e.,
HTTPS).
Innominate Security Technologies
97
Configuring the mGuard
pci²
SD
•
Enter the following address into the browser: https://1.1.1.1/
The connection to the mGuard
pci²
SD is established. (If not, see Section
5.5.2).
A security message indicating a possible invalid/not trusted certificate is displayed. This
message results from the use of an mGuard certificate from Innominate that is not yet known
to the browser but necessary for encryption of the communication.
•
Acknowledge this message with “Accept this certificate always/temporarily” (Mozilla
Firefox), “Continue loading this website” (Internet Explorer), “Continue anyway”
(Google Chrome).
•
Click “Yes” to acknowledge the security alert.
The login window is displayed.
Figure
5-4
Login
•
To log in, enter the preset user name and password (please note these settings are
case-sensitive):
To configure the device, make the desired or necessary settings on the individual pages of
the mGuard web interface.
User Name:
admin
Password:
mGuard
For security reasons, we recommend you change the default root and administrator pass-
words during initial configuration (in the web interface under “Authentication >> Adminis-
trative Users”).
Innominate Security Technologies
I15007_en_02
5.5.2
Starting up the mGuard
pci²
SD via a temporary manage-
ment IP address
If the mGuard
pci²
SD is connected without a functioning external network in initial startup
mode, the device cannot be accessed via address https://1.1.1.1/.
In this case, the mGuard
pci²
SD is accessible automatically via management IP address
192.168.1.1/24. This applies to the internal (LAN
1) and the external (WAN
1) network inter-
faces. An address conflict with the external network interface is not possible as long as
WAN
1 is not connected to a functioning network. This management IP address is normally
non-persistent.
Starting up the mGuard
pci²
SD without external network
•
Connect the internal network interface (LAN 1) of the mGuard
pci²
SD to the corre-
sponding Ethernet network card of the configuration computer or a valid network con-
nection of the internal network.
•
Disconnect the external network interface (WAN
1) of the mGuard
pci²
SD from the ex-
ternal network (WAN).
•
Switch on the system. The STAT LED lights up green when the supply voltage has been
connected properly.
The mGuard boots the firmware. The STAT LED flashes green.
Adapting the configuration computer
In order to access the mGuard
pci² for configuration, the configuration computer must be
adapted to the management IP address of the mGuard
pci²
SD.
Example of Microsoft Windows XP:
•
Set the following in the “Internet Protocol (TCP/IP) Properties” of the relevant network
interface of the configuration computer:
•
Enter the address assigned into the browser: https://192.168.1.1/
•
Configure the mGuard as described in “Configuring the mGuard
pci²
SD” on page
97.
However, if the external network interface (WAN
1) is connected after booting the
mGuard
pci²
SD, the management IP address remains valid. In this case, an address
conflict with an existing address in the external network is possible.
IP address:
192.168.1.10
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.2
Innominate Security Technologies
99
5.5.3
Starting up mGuard
pci²
SD via BootP
In initial startup mode, the mGuard
pci² additionally starts a BootP client on the internal net-
work interface (LAN 1). The BootP client is compatible with the “IPAssign” BootP servers
from Phoenix Contact as well as “DHCPD” under Linux.
This software can either be downloaded free of charge at phoenixcontact.net/products or at
www.innominate.com under "Downloads > Software".
If an non-configured mGuard
pci²
SD accesses a BootP server after booting, the BootP pro-
tocol assigns an IP address, a subnet mask, and optionally a default gateway of the internal
network interface to the mGuard
pci²
SD. These parameters are saved in the device which
can then be immediately accessed under these parameters.
•
Enter the address assigned via BootP in the browser: e.g., https://192.168.1.1/
Configure the mGuard as described in “Configuring the mGuard
pci²
SD” on page
97.
IP address assignment using IPAssign is described in detail in “Assigning the IP address
using IPAssign.exe” on page
255.
Innominate Security Technologies
I15007_en_02
5.5.4
Assigning the IP address via BootP
For IP address assignment, the mGuard uses the BootP protocol. The IP address can also
be assigned via BootP. On the Internet, numerous BootP servers are available. You can use
any of these programs for address assignment.
Section 14.1 explains IP address assignment using the free Windows software
“IP
Assignment
Tool” (IPAssign.exe).
Notes for BootP
During initial startup, the mGuard transmits BootP requests without interruption until it re-
ceives a valid IP address. After receiving a valid IP address, the mGuard no longer sends
BootP requests. The product can then no longer be accessed via IP address 192.168.1.1.
After receiving a BootP reply, the mGuard no longer sends BootP requests, not even after
it has been restarted. For the mGuard to send BootP requests again, it must either be set to
the default settings or one of the procedures (recovery or flash) must be performed.
Requirements
The mGuard is connected to a computer using a Microsoft Windows operating system.
After assigning an IP address via BootP, the product can no longer be accessed via IP ad-
dress 192.168.1.1