Arcam A80 Service Manual
Text of Arcam A80 Service Manual
P80 Power Amplifier
Issue 1.0
ARCAM
ARCAM
Bringing music & movies to
Bringing music & movies to
Arcam A80 ! Circuit description
o A80/P80
! Technical specifications
! Circuit diagrams
o L943AY
! Transformers
o L916TX – 115/230VAC toroidal
o L917TX – 100VAC toroidal
o L907TX – 100VAC frame
! Exploded view diagram
o A80
! Mechanical & packing parts list
o A80
o P80
! Circuit board silk screen
o A80
o P80
! Circuit board parts list
o A80/P80 combined
The mains input to the unit is supplied at SK200 and is
filtered the Y Caps and locations C200 /C201 and X
cap at location C209, these are in-place to reduce
mains born HF interference and to prevent bridge
rectifier noise from leaving the unit.
The mains select switch at location SW200 works in
conjunction with the dual primaries on the 115/230v
transformers, the switch allows for the units to be used
in territories runn
Arcam A80 Into the power amp stages but from this point we can
configure the unit as a separate Pre amp/Power amp
by moving the jumpers to the pin 2 and 3 of Con 304
and Con 305, and then remove the jumpers at Con
302 and Con 303 this may also be of use when fault
finding as we can effectively isolate the and D.C
offset/distortion problems coming from the Pre amp
stage to the power amp stages and test these stages
as a separate entity.
The Pre amp power up mute and
Fig 4. Suggested blanket replacement parts for
power amp failures.
Location Description
Model
Part no.
TR413
Output driver +
SAP15NY
4CSAP15N
TR415
Output driver -
SAP15PY
4CSAP15P
TR410
Predriver +
FMMT 497
4AFMMT497
TR412
Predriver +
ZDT 6758
4AZDT6758
TR414
Predriver -
ZDT 758
4AZDT758
TR405
Predriver -
FMMT 597
4AFMMT597
TR401
Current mirror PNP
BC859B
4A859
TR402
Current mirror PNP
FMMT 597
4AFMMT597
TR411
Current mirror NPN
FMMT 497
4AFMMT497
TR417
C
The Protection is live at all times that even in standby
due to the fact that all chips related with these
functions are driven from the 4.8(D) supply rails.
As we can see from Fig 4 we can isolate the left and
right channel protection lines for both over current and
D.C offset by looking at the protection lines before they
are mixed into single fault status lines for the micro at
location IC600 this will allow us to identify the channel
that is “flaggin
Fig 9. Major components pin identification.
74HC14
TLO 72
NJM2114
DG408DY
74HC00D
ZDT 758/ZDT 6758
1=Collector 1
2=Collector 1
3=Collector 2
4=Collector 2
5=Emitter 2
6=Base 2
7=Emitter 1
8=Base 1
FMMT 497/597
Continuous Power output
Both channels driven 8 ohms 20 Hz – 20 kHz = 65 Watts
Single Channel driven 4 ohms 20 Hz – 20 kHz = 80 Watts
Distortion 8 ohms at 80% power output 1Khz = 0.008%
Input stage specifications.
RIAA input stage sensitivity (M.M) = 2.5 mV
Line input sensitivity = 630 mV (Default)
Input impedance
DESCRIPTION OF CHANGE
L943C1_5.1.SCH
A80/P80 - Top Level Sheet
Contact Engineer:
L943C1
9-Sep-2003
INITIALS
Printed:
1
8
Sheet
of
Notes:
Contact Tel:
(01223) 203 200
Mark Tweedale
A & R Cambridge Ltd.
Pembroke Avenue
Cambridge CB5 9PB
Waterbeach
23425
-45V_R
+45V_R
0V(SIG)
-45V_L
+45V_L
0V_LS_L
+4.8V(D)
9VRMS
PWR_ON
-38V_VFD
0V(D)
0V_HF_L
0V_FB_L
0V_FB_R
0V_HF_R
0V_LS_R
+15V(A)
+5V(A)
-15V(A)
0V(PSU)
FIL_
DESCRIPTION OF CHANGE L943C2_5.1.SCH
A80/P80 Power Supplies
Contact Engineer:
L943C2
9-Sep-2003
INITIALS
Printed:
2
8
Sheet
of
Notes:
Contact Tel:
(01223) 203 200
Mark Tweedale
A & R Cambridge Ltd.
Pembroke Avenue
Cambridge CB5 9PB
Waterbeach
23425
EARTH
MAINS WIRING AND AUXILIARY SUPPLY
0V(D)
+4.8V(D)
0V(D)
+4.8V(D)
ANALOGUE OP-AMP SUPPLIES
-15V(A)
+15V(A)
EMC Shield
SH200
1
L
N
E
SKT200
BULGIN
PX0580
C2
DESCRIPTION OF CHANGE L943C4_5.1.SCH
A80/P80 - Power Amp Left
Contact Engineer:
L943C4
9-Sep-2003
INITIALS
Printed:
4
8
Sheet
of
Notes:
Contact Tel:
(01223) 203 200
Mark Tweedale
A & R Cambridge Ltd.
Pembroke Avenue
Cambridge CB5 9PB
Waterbeach
23425
0V_FB_L
PRE_OUT_L
0V_HF_L
0V_LS_L
0V_HF_L
VIPROT_L
OUTPUT_L
0V_LS_L
0V_HF_L
+45V_L
-45V_L
0V_HF_L
0V_HF_L
BIAS
MEASURE BIAS
INPUT FILTER
V TO I AMP
INTEGRATI
DESCRIPTION OF CHANGE L943C5_5.1.SCH
A80/P80 - Power Amp Right
Contact Engineer:
L943C5
9-Sep-2003
INITIALS
Printed:
5
8
Sheet
of
Notes:
Contact Tel:
(01223) 203 200
Mark Tweedale
A & R Cambridge Ltd.
Pembroke Avenue
Cambridge CB5 9PB
Waterbeach
23425
->
0V_FB_R
PRE_OUT_R
0V_HF_R
0V_LS_R
0V_HF_R
VIPROT_R
OUTPUT_R
0V_LS_R
0V_HF_R
+45V_R
-45V_R
0V_HF_R
0V_HF_R
BIAS
MEASURE BIAS
INPUT FILTER
V TO I AMP
INTEG
DESCRIPTION OF CHANGE L943C8_5.1.SCH
A80 & P80 Display Circuitry
Contact Engineer:
L943C8
9-Sep-2003
INITIALS
Printed:
8
8
Sheet
of
Notes:
Contact Tel:
(01223) 203 200
Mark Tweedale
A & R Cambridge Ltd.
Pembroke Avenue
Cambridge CB5 9QR
Waterbeach
ARCAM
A2
LED805
5mm
GRN
LED 5mm
LED804
5mm
GRN
LED 5mm
LED803
5mm
GRN
LED 5mm
R834
330R
0W125
0805
R835
330R
0W125
0805
R836
330R
0W125
0805
+4.8V(D)_DISP
-25V(
DESCRIPTION OF CHANGE L943C7_5.1.SCH
A80/P80 Trig, RC5 & P80 Sig Det
Contact Engineer:
L943C7
9-Sep-2003
INITIALS
Printed:
7
8
Sheet
of
Notes:
Contact Tel:
(01223) 203 200
Mark Tweedale
A & R Cambridge Ltd.
Pembroke Avenue
Cambridge CB5 9PB
Waterbeach
23425
P80 SIG DETECT
PRE_OUT_L
PRE_OUT_R
0V(D)
Q0
9
Q1
7
Q2
6
Q3
5
Q4
3
Q5
2
Q6
4
Q7
13
MR
11
CP
10
Q8
12
Q9
14
Q10
15
Q11
1
IC701A
74HCT4040D
SO-16
0V(D)
I
DESCRIPTION OF CHANGE L943C6_5.1.SCH
A80/P80 Protection & Micros
Contact Engineer:
L943C6
9-Sep-2003
INITIALS
Printed:
6
8
Sheet
of
Notes:
Contact Tel:
(01223) 203 200
Mark Tweedale
A & R Cambridge Ltd.
Pembroke Avenue
Cambridge CB5 9PB
Waterbeach
23425
TO DISPLAY - SHEET 8
0V(D)
+4.8V(D)
-38V_VFD
LISTEN_2
LISTEN_1
LISTEN_0
VOL_SDATA
VOL_SCLK
TAPE_0
TO SHEET 3
3
4
IC601B
74HC14
SO-14
5
6
IC601C
74HC14
SO-
DESCRIPTION OF CHANGE L943C3_5.1.SCH
A80 PreAmp
Contact Engineer:
L943C3
9-Sep-2003
INITIALS
Printed:
3
8
Sheet
of
Notes:
Contact Tel:
(01223) 203 200
Mark Tweedale
A & R Cambridge Ltd.
Pembroke Avenue
Cambridge CB5 9PB
Waterbeach
23425
0V(SIG)
0V(SIG)
0V(SIG)
0V(SIG)
+15V(A)
-15V(A)
+15V(A)
-15V(A)
0V(SIG)
0V(SIG)
0V(SIG)
+15V(A)
-15V(A)
0V(SIG)
+15V(A)
-15V(A)
-15V(A)
-15V(A)
LINE OUTPUT
AUX2 L
CD L
TUN