golmar Stadio Plus Instruction Manual

Text of the manual

Audio and Video

door entry system digital installation with coded panel T7403ML rev.0208

First of all we would like to thank and congratulate you for the purchase of this product

manufactured by Golmar. The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification and for the manufacturing of products like this one. Its advanced technology and exacting quality control will do that customers and users enjo

Do not use excessive force when tightening the power supply connector screws.

Install the equipment without the power connected. Disconnect from power before any system modification. Check that the input voltage is lower than 230Va.c. Before to connect the system, check the connections between door panel, monitors and telephones, and the transform

One building systems.

O To make a call, the visitor should key-in the three digits code corresponding to the apartment he wishes to contact: the door panel display will show the sequence keyed-in. Once the code has been introduced, press bell key to confirm the call: acoustic tones will be heard confirming the call is in progress and the

mbedding box positioning.

E 1650 1850 1450 The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions will depend on the number of door panel modules (see page 108).: The door panel has been designed to be placed under most of the environmental conditions. However it's recommended to ta

The doorpanel has a microswitch (SW1) and two jumpers

(JP1and JP2) placed on the rear part of the doorpanel. Loads the installation with a communications resistor. For a proper system operation, activate this resistor only in the closest doorpanel to the backbone installation or in the general entrance doorpanel (if exists).

The doorpanel has two memory banks

to plug 256Kb memory modules in. Each module allows to record the custom text for a maximum of 968 users. The system is delivered with one memory module placed in the bank number 0 (BK0), where the system configuration will be recorded. IMPORTANT: in case of doorpanels with

Access control options can be changed on

this menu. Press to enter into this menu. access control This menu allows to fill the repertory and to change its options. Press to enter into this menu. repertory Continue pin code pin:____ or On this menu the system configuration optio

Coming from previous page

configuration :000 panel address modify value :000 :015 panel address * yes general panel * yes master panel * english yes panel w. camera * To enter into configuration menu, follow the steps described on the previous page and press when the display shows the

call to exchange

* yes yes autoswitch-on direct call code * * Allows the activation of a second call code for each apartment, that can be different to the programmed call code. This code must be assigned on the repertory menu (page 90). Press to disable or enable this feature. 16:24 16:24 17:30 set time modify val