DynaLock 3000 Series Manual 

Text of the manual

PLEASE READ BEFORE ATTEMPTING INSTALLATIONS

3000/ 3000LC/ 2000 SERIES CIRCUIT BOARD DESCRIPTION Refer to Page 2 & 3 for wiring and voltage instructions �Power Input and Control Fig "A, B & E" �Door Status Fig "D" �Dynastat Fig "C" L2 OPTION - FUNCTION Requires Dynastat option to work. Red = secure / Green = unsecure Reversing plug direction changes light indication. ATS OPTION - WIRING Indicator device, by others, illuminates / sounds when access cover is removed. Contact Rating: SPDT @ 0.5A DYNASTAT CONNECTOR TIME DELAY ADJ. CW to increase. Range 1-80 seconds see fi g. "E" � 3000/2000 series mag lock accepts 12/24 VAC/DC � Circuit board shown fully loaded, with every option ATS SWITCH LED 3 Pin Plug LOCK HOUSING Wht Wht 2 Pin Plug not polarized COIL CONNECTOR PLUG The Coil Connector is not polarized and may go on in either direction. Blk Blk Wht Wht 4 Pin Plug COIL PLUG RECEPTACLE VOLTAGE SELECTION JUMPERS - See page 2 SECURE TAMPER POWER INPUT FOR ATS OPTION GRN WHT RED COM. NO NC 1 DynaLock Corp. � 705 Emmett Street � P.O. Box 2728 � Bristol, CT 06011-2728 � 1-877-DYNALOCK � www.dynalock.com Electromagnetic Locking Systems

HOW TO SET VOLTAGE

Voltage is set by proper placement of the blue jumper caps on 4 exposed pins Set for 12 Volts 2 jumpers Removable Jumpers Voltage Selection Set for 24 Volts 1 jumper FACTORY SET FOR 24 VOLTS WIRING INSTRUCTIONS 3000/2000 12/24 VDC INPUT 3000/2000 12/24 VAC INPUT (+) 12 / 24 VDC INPUT (-) FIG. A FIG. B INPUT FROM INDICATOR POWER SOURCE DOOR CLOSED DOOR OPEN NOTES: 1. DSM CONTACTS RATED 0.25A MAXIMUM 2. INDICATORS NOT INCLUDED 12 / 24 VAC INPUT NORMALLY CLOSED STATION CONTROL(S), I.E. PUSHBUTTONS, KEYSWITCHES, ETC. WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN. NORMALLY CLOSED STATION CONTROL(S), I.E. PUSHBUTTONS, KEYSWITCHES, ETC. WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN. FIG. D 3000/2000 DYNASTAT OPTION 3000/2000 DSM OPTION DOOR SECURE DOOR UNSECURE NOTES: 1. DYNASTAT CONTACTS RATED 1A MAXIMUM 2. INDICATORS NOT INCLUDED INPUT FROM INDICATOR POWER SOURCE FIG. C LOCK POWER INPUT }USE FIGURES A OR B } LOCK POWER INPUT USE FIGURES A OR B 2 C NO NC NO NC C 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10

COIL RESISTANCE CHECK

REMOVE THE MAGNET COIL CONNECTOR FROM THE CIRCUIT BOARD TO PERFORM THE COIL TEST PROPER COIL RESISTANCE SHOULD BE FROM POINTS 1 TO 3, ~ 53 OHMS FROM POINTS 2 TO 4, ~ 53 OHMS ELECTRICAL SPECIFICATIONS OPERATING VOLTAGES 12 OR 24 VAC / VDC CURRENT CONSUMPTION, ALL MODELS 12 VAC / VDC - 0.44 A 24 VAC / VDC - 0.22 A Notes: 1. This lock may accept any one of 4 different input voltages and be furnished with a combination of options. Refer to page 1 for option location and pages 2 and 3, fi gure A thru E, for wiring instructions that apply to your specifi c installation. 2. For additional system wiring information, refer to the installation documentation furnished with the external hardware and / or peripheral devices (I.E. power supply, station controls, keypad, card readers, etc.) supplied by DynaLock and / or others. 3000 / 2000 TD OPTION (TIME DELAY) 12 / 24 VAC / VDC INPUT NORMALLY CLOSED STATION CONTROL(S), I.E. PUSHBUTTONS, KEYSWITCHES, ETC. WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN. FIG. E TIME DELAY OPERATION 1. PUT A JUMPER ACROSS TERMINALS 3 & 4. 2. MOMENTARILY OPENING THE CONTACT(S) AND INTERRUPTING THE POWER ON 1 & 2 UNLOCKS THE DOOR. THE DOOR WILL RELOCK AFTER THE DURATION OF THE TD. 3. SEE PAGE ONE FOR THE LOCATION OF THE TIMER ADJUSTMENT CONTROL. 4. TIME ADJUSTMENT RANGE IS ONE (1) TO EIGHTY (80) SECONDS. 3 ADD JUMPER 1 2 3 4 5 6 7 8 9 10

DOOR WILL NOT LOCK

NO INPUT POWER CHECK ALL CONNECTIONS. OR NO MAGNETIC CHECK FOR VOLTAGE AT POWER SOURCE HOLDING FORCE AND LOCK TERMINAL STRIP. REVERSED POLARITY IF A LOCK IS OPERATING ON DC VOLTAGE CHECK FOR REVERSED POLARITY. REFER TO FIG "A" PAGE 2. AN OPEN CIRCUIT PERFORM THE COIL RESISTANCE CHECK. IN THE COIL REFER TO BOTTOM OF THE PAGE 3. LOW HOLDING FORCE WRONG INPUT VOLTAGE VERIFY INPUT VOLTAGE MATCHES JUMPER SETTING. SEE TOP OF PAGE 2. VOLTAGE SELECT JUMPERS VERIFY THAT JUMPERS MATCH INPUT SET WRONG VOLTAGE. SEE TOP OF PAGE 2. ARMATURE MOUNTING CHECK ARMATURE MOUNTING FOR FREE TOO RIGID PIVOTING AND FULL CONTACT BETWEEN THE MATING SURFACE OF THE LOCK AND ARMATURE. MAGNET OVERHEATS LOCK SET FOR 12V WITH VERIFY THAT JUMPERS MATCH AND / OR DRAWS EXCESS 24V APPLIED INPUT VOLTAGE. SEE TOP OF PAGE 2. CURRENT POSSIBLE SHORTED COIL PERFORM THE COIL RESISTANCE CHECK. REFER TO BOTTOM OF PAGE 3. DYNASTAT BOND SENSOR INSUFFICIENT SUPPLY VOLTAGE CHECK SUPPLY FOR PROPER INPUT NOT INDICATING DOOR VOLTAGE, SHOULD BE WITHIN 10% SECURE WHEN CLOSED AND LOCKED MAGNET AND / OR ARMATURE CLEAN BOTH SURFACES WITH SCOTCH (WHEN APPLICABLE) FACE DIRTY OR BURRED BRITE TYPE CLOTH AND APPLY WD-40. CHECK FOR BURRS. POOR LOCK / ARMATURE CORRECT AS NECESSARY ALIGNMENT DSM (DOOR STATUS DSM MAGNETS NOT INSTALLED REPLACE / INSTALL AS NECESSARY MONITOR) NOT IN ARMATURE HOUSING INDICATING DOOR CLOSED / OPEN STATUS (WHEN APPLICABLE) POOR LOCK / ARMATURE CORRECT AS NECESSARY ALIGNMENT 4 2000-3000 Wiring Manual 02-07

LP - LOW POWER OPTION

SUPPLEMENTAL INSTRUCTIONS DynaLock 705 Emmett Street Bristol, CT 06011-2728 Phone:(860)582-4761 Fax:(860)585-0338 DynaLock 3000 and 2000 Series electromagnetic locks equipped with the LP - Low Power Option are confi gured to operate exclusively on 12V AC/DC input voltage. Current draw is 0.16 Amps for single models and 0.32 Amps for double models. Damage may occur if input voltage exceeds 16V AC/DC. Do not attempt operation at higher voltages. GENERAL INFORMATION BASIC INPUT POWER WIRING 3000/2000 x LP BASIC 12 VDC INPUT (+) 12VDC INPUT (-) FIG. A NORMALLY CLOSED STATION CONTROL(S), I.E. PUSHBUTTONS, KEYSWITCHS, ETC. WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN. 1 2 3 4 5 6 7 8 9 10 3000/2000 x LP BASIC 12 VAC INPUT 12VAC INPUT FIG. B NORMALLY CLOSED STATION CONTROL(S), I.E. PUSHBUTTONS, KEYSWITCHS, ETC. WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN. 1 2 3 4 5 6 7 8 9 10

FOR UNITS USING THE CIRCUIT BOARD

DISCARD THE MOV AND THIS PAGE. BLACK WHITE BLACK WHITE 1 2 3 4 12 VOLT DC OPERATION MOV + - BLACK WHITE BLACK WHITE 1 2 3 4 MOV + - 24 VOLT DC OPERATION NOTE: TO PROTECT OTHER ELECTRONIC DEVICES IN SYSTEM CONNECT THE SUPPLIED MOV ACROSS THE LEADS AS SHOWN ABOVE. NOTE: TO PROTECT OTHER ELECTRONIC DEVICES IN SYSTEM CONNECT THE SUPPLIED MOV ACROSS THE LEADS AS SHOWN ABOVE. JUMPER WIRING INSTRUCTIONS DynaLock 705 Emmett Street Bristol, CT 06011-2728 Phone:(860)582-4761 Fax:(860)585-0338 SERIES 2000/3000 x LCB ELECTROMAGNETIC LOCK