Caframo BDC2002 Operation & User’s Manual

Specifications

Brand: Caframo
Category: Laboratory Equipment
Model: BDC2002 (Operation & User’s Manual), prrwFEBlRuE4o
File Type: PDF
File Size: —
Pages: 72 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (72 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 21/06/2026).

Read Online

Read the Caframo BDC2002 Operation & User’s Manual online using the built-in PDF viewer.

BDC2002 Operation & User’s Manual: Key Pages of Document

Online Warranty Registration

To register the warranty for your Caframo stirrer online, please complete the registration found at CaframoLabSolutions.com/product-registration/ ...

Language Index 

1 Packing List  2 Introduction  2 Safety Label Legend  2 Safety Instructions  3 General Instructions  4 Approvals  4 Installation  5 Environmental Operating Conditions  5 Auto Start 6 Torque Capabilities  7 BDC2002 Dimensions  8 BDC2010 Dimensions 9 BDC2002 Technical Data 10 BDC2010 Technical Data 11 BDC2002 General Operating Instructions 12 BDC2010 General Operating Instructions 13 Cleaning and Service  15 Warranty and Product Liability 16 BDCMN004 Rev00 Language Index English...................................................................................................................1 French....... ...

Compare the contents of the shipment to the items on the following list to ensure

all parts are received with the stirrer. Do not discard the container and packing materials until all parts are accounted for. It is recommended that the original packing materials be kept for transportation and storage. • Overhead Stirrer • Power Supply with 120 volt cord set or Power Supply with 220-240 volt cord sets (U1) • Support Rod (including cap screw and lock washer) • Chuck Key • Instruction manual U1 Cord Sets Included with BDC2002U1, BDC2010U1. a. United Kingdom b. Europe RoHS compliant & CE marked. Introduction This stirrer is spe ...

All operators must be familiar with the stirrer and read this entire manual.

If the stirrer is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 2. The stirrer must be securely fixed to a stable support. Mount to a Caframo stand using a Caframo heavy duty clamp. If other stands or clamps are used, the stirrer must be secured such that it will not fall if tipped. 3. CAUTION: This is not an explosion proof stirrer. Do not use in a highly flammable or explosive environment. 4. Spinning impellers can cause severe personal injuries. Operators must use extreme ca ...

Read Safety Instructions: Unpack the stirrer carefully. Ensure the stirrer is not

damaged and verify the contents against the packing list. If the stirrer is damaged or the contents do not correspond with the packing list, notify your supplier im­ mediately. Read the manual carefully! Make sure that all users read this manual thoroughly before operating the stirrer. For further questions or inquiries, please contact: Caframo Limited 501273 Grey Road 1 Georgian Bluffs ON N0H 2T0, Canada Tel: 519-534-1080 Toll Free: 800-567-3556 (within USA and Canada) Website: CaframoLabSolutions.com E-mail: [email protected] Approvals S ...

Installing the support rod

Remove the hex screw and lock washer from the support rod. Insert the support rod into the back of the stirrer so that the holes line up for the hex screw. Secure with hex screw and lock washer and tighten with hex key. Clamp the stirrer to a Caframo stand on a stable, level surface (see Safety Instruc­ tions). Connect stirrer to supplied Caframo power supply. Connect power supply to a grounded electrical outlet. Impeller attachment Insert the impeller shaft into the open chuck and adjust the impeller to the desired height. The hollow shaft allows the impeller shaft to come through the top of the stirrer i ...

This stirrer includes an optional Auto Start feature. When set, the stirrer will resume

mixing after a power failure, when power has been removed by control equipment (i.e., PLC) or when the AC power has been cut (i.e., stirrer unplugged). When power is restored, the stirrer will automatically ramp up to the last set speed and resume mixing. The stirrer ships from the factory with Auto Start disabled. To set the Auto Start feature first ensure the stirrer is powered off. Press and hold the Increase Button then press the Power Button. When active, Auto Start is indi­ cated by: BDC2002 - A solid LED dot in the bottom right corner of the dis ...

BDC2002 Torque Curve

0 10 20 30 40 50 60 70 80 0 200 400 600 800 1000 1200 1400 1600 1800 Torque (Ncm) RPM BDC2010 Torque Curve 0 10 20 30 40 50 60 70 80 90 100 0 200 400 600 800 1000 1200 1400 1600 1800 Torque (Ncm) RPM ...

37.00 mm dia.

[1.5 in] 76.1 mm [3.0 in] 185.9 mm [7.3 in]              j Ergonomic Carry Handle  Rubber Gasket  Stirlight™  Button - Power on/off  Button - Increase rpm  Button - Decrease rpm  Button - Light on/off  Four Digit LED Display  Chuck  1/2 in dia Support Rod  Splash Guard  Housing - Molded Front  Housing - Cast Back ...

37.00 mm dia.

[1.5 in] 76.1 mm [3.0 in] 185.9 mm [7.3 in]                j Rubber Gasket  Stirlight™  Button - Power on/off  Four Digit LED Display  Multi-Function Button  Button - Increase/Decrease rpm  Button - Reverse direction  Button - Start/Pause  Button - Light on/off  Chuck  1/2 in dia Support Rod  Splash Guard  Housing - Molded Front  Housing - Cast Back  Ergonomic Carry Handle ...

BDC2002 Technical Data

Model Number BDC2002 Speed Range 40 - 2002 rpm Speed Readout Accuracy ± 1 rpm or 3% of reading, 4 digit Maximum Torque 70 Ncm, (100 in-oz) Input To Power Supply AC 100-240 volts, 50/60 Hz, 2.0 amps (Must use Caframo supplied power supply.) Electrical Output from Power Supply to Stirrer DC 24 volt, 3.1 amps Mechanical Output Power 1/18 hp, 40 watts, (Brushless DC Motor) Weight - Stirrer Only Weight - Power Supply 3.0 kg (7 lbs) 0.5 kg (1 lbs) Maximum Volume 25 litres (6.6 US gallons) Maximum Viscosity 15,000 cps - e.g. sour cream Molded Front Housing Flame retardant, chemical resistant, high impact nylon. Recyclable (PA). Cas ...

BDC2010 Technical Data

Model Number BDC2010 Speed Range 40 - 2010 rpm Functions Countdown Timer Clockwise Counter Clockwise xRx Agitation Speed Readout Accuracy ± 1 rpm or 3% of reading, 4 digit Maximum Torque 90 Ncm, (127 in-oz) Input To Power Supply AC 100-240 volts, 50/60 Hz, 2.5 amps (Must use Caframo supplied power supply.) Electrical Output from Power Supply to Stirrer DC 24 volts, 3.75 amps Mechanical Output Power 1/15 hp, 50 watts, (Brushless DC Motor) Weight - Stirrer Only Weight - Power Supply 3.0 kg (7 lbs) 0.6 kg (1.2 lbs) Maximum Volume 25 litres (6.6 US gallons) Maximum Viscosity 20,000 cps - e.g. chocolate syrup Molded Front Housing ...

BDC2002 General Operating Instructions

Make sure the stirrer is securely mounted as specified in the installation instruc­ tions. Ensure the mixing paddle or impeller is securely attached at the desired position. The stirrer is now ready for use to mix liquids and liquid/solid solutions. Appro­ priate impeller and container specifications must be determined by the operator, ensuring that all safety instructions are followed. Keypad Functions Power Button - Turns the stirrer motor on and off. When initially turned on, stirrer will spin at 40 rpm following a 5 second delay. The last set speed is remembered. Increase Button - Increases the speed ...

OH Indicates an overheat condition. The operating conditions have caused the

stirrer to overheat. Reduce stirrer loads and / or environmental temperature to continue mixing. To reset stirrer turn power off, allow stirrer to cool and then turn back on. BDC2010 General Operating Instructions Make sure the stirrer is securely mounted as specified in the installation instruc­ tions. Ensure the mixing paddle or impeller is securely attached at the desired position. The stirrer is now ready for use to mix liquids and liquid/solid solutions. Appro­ priate impeller and container specifications must be determined by the operator, ensuring that all s ...

Turn the stirrer on by pressing the power button. The display will read 40 rpm and

the speed LED dot will be illuminated. Increase to the desired speed and press the start/pause button. The stirrer will start turning in a clockwise direction. The speed LED dot will be illuminated (solid) and the speed value in rpm will be displayed. Counter Clockwise Mixing Set by following the clockwise stirring instructions above. Press the reverse button. The reverse button can be pressed while the stirrer is running to mix in a counter clockwise direction. The LED dot above the reversing icon will be illuminated (sol­ id) when mixing in a ...

stirrer is paused and the indicator lights are solid.

The multifunction button can be pressed when the stirrer is running to view the status of each function. For safety, a “soft start” has been incorporated into the stirrer. The stirrer will ramp up to reach the set speed to minimize splashing. Display Codes OL Indicates an overload condition. The load is too great for the stirrer and must be reduced. Press the power button, enter in new parameters and start. OH Indicates an overheat condition. The operating conditions have caused the stirrer to overheat. Reduce stirrer loads and/or environmental temperature to continue mixing. To res ...

Warranty and Product Liability

Warranty Caframo warrants the herein described product of its manufacture for three years from receipt of the equipment by the purchaser, against defects in material and workmanship. Warranty registration is available on the Service and Support page of our website (CaframoLabSolutions.com). This limited warranty covers parts and labour. If the stirrer housing is opened, the warranty becomes void. This warranty may only be altered by a specifically published amendment. No individual has authorization to alter the provisions of this warranty policy or its amendments. Expendable items are not covered by this warranty. ...

Index Langue 

17 Liste de colisage  18 Introduction  18 Légende des étiquettes de sécurité  18 Consignes de sécurité  19 Instructions générales  20 Homologations  20 Installation  21 Environnement et conditions de fonctionnement  21 Auto Start 22 Capacités de couple 23 BDC2002 Dimensions  24 BDC2010 Dimensions 25 BDC2002 Données techniques 26 BDC2010 Données techniques 27 BDC2002 Consignes générales de fonctionnement 28 BDC2010 Consignes générales de fonctionnement 29 Nettoyage et maintenance  31 Garantie et responsabilité produit 32 Index Langue Anglais................................................... ...

Liste de colisage

Vérifier que tous les éléments figurant dans la liste suivante sont contenus dans l’emballage. Ne pas jeter le contenant et l’emballage tant que cette vérification n’a pas été effectuée. Il est recommandé de garder l’emballage d’origine pour le transport et l’entreposage. • Overhead Stirrer • Alimentation électrique avec extrémité de cordon 120 volt ou Bloc d’alimentation électrique avec extrémité du cordon pour 220-240 volt (U1) • Barre d’appui (y compris vis creuse à six pans, rondelle de sécurité et clé) • Clé de mandrin • Mode d’emploi U1 Cord Sets Inclus avec BDC2002U1, BDC2010 ...

Laboratory Equipment PDF Instructions

TSX Series
Thermo Scientific TSX Series
18.06.2026 62 pages

Ultra Low Temperature Freezers TSX Series Installation and Operation 327228H01 Rev. A January 2015 Visit us online to register your warranty www.thermoscientific.com/labwarranty Professional operation guide for the Thermo Scientific TSX Series Freezer. This guide offers guidance on interface navigation, user preferences, safety precautions, operating guidelines.

STERIL FAN SFA2030F
Tecnomed Italia STERIL FAN SFA2030F
30.08.2026 44 pages

STERIL FAN Wall-mounted UVGI air sterilizer SFA2030F // SFA2045F V.8.00 all-guides com Product reference manual for the Tecnomed Italia STERIL FAN SFA2030F Laboratory Equipment. It describes step-by-step regulatory notices, hardware setup, installation procedures, replacement parts.

D-6011
Neolab D-6011
13.07.2026 4 pages

User Manual neoLab-Analog Magnetic Stirrer Item N°. D-6011 Users should read this manual carefully, follow the instructions and procedures, and be aware of the dangers while using this instrument. Safety Instructions: Warning! • Read the operating instructi Quick start guide for the Neolab D-6011 Laboratory Equipment. It details safety instructions and connectivity setup, power requirements, backup procedures.

Precise CA 5220100
Labconco Precise CA 5220100
18.03.2026 63 pages

Labconco Corporation 8811 Prospect Avenue Kansas City, MO 64132-2696 800-821-5525, 816-333-8811 FAX 816-363-0130 E-MAIL [email protected] HOME PAGE www.labconco.com To receive important product updates, complete your product registration card online at reg Operational manual for the Labconco Precise CA 5220100 Laboratory Equipment. It describes step-by-step compatibility information, security instructions, technical guidelines.