Badger Meter ORION SE Installation Data
Text of Badger Meter ORION SE Installation Data
62014-144 Rev. 2
IMPORTANT:
This manual contains important information.
READ AND KEEP FOR REFERENCE.
Product Unpacking and Inspection.........................................................................................................................5
License Requirements....................................................................................
This manual contains installation and programming instructions for the ORION® water endpoint.
Proper performance and reliability of ORION endpoints depend upon installation in accordance with these instructions.
Product Unpacking and Inspection
Upon receipt of the product, perform the following unpacking and inspection procedures.
NOTE: If damage to the shipping container is evident upon receipt, request the carrier to be presen
ORION® Water Endpoint
Identification
Each ORION endpoint can be identified using the unique numeric serial number located on a tag attached to the wire harness
and etched on the top (CE) or side (SE, ME) of the endpoint housing. Each Badger Meter encoder is clearly identified on the
face of the register with an assembly number, unit of measure and meter model.
SE/ME Endpoint (Medium Gray)
CE RTR® Endpoint (Black)
CE ADE® Endpoint (Light Gray)
Recordall
Network Endpoint Installation
When installing an SE or ME (used with a network gateway transceiver) or CE (used with an ORION 4.0 or 2.0 gateway
receiver) endpoint in a pit, the endpoint must be mounted through the lid of a non-metal pit lid for maximum propagation
of the radio signal. If the endpoint is being installed indoors, a wired radio endpoint should be mounted on the outside
of the building or in the floor joist near the outside
ORION® Water Endpoint Pit Installation
Through the Lid Installation Kit (SE, ME and CE Endpoints)
The Through the Lid Installation Kit is designed for use with a lid with maximum thickness of one-inch, and a standard
hole diameter of 1-7/8 inches.
Figure 2: ORION Pit Endpoint
To install the endpoint through the lid, follow these steps per Figure 2.
1.
Screw the nut onto the tube threads as shown.
2. Insert the tube through the bottom of the lid.
3. Scr
Below Lid with Knuckles Installation Kit (ME and CE Endpoints)
For below the lid installations, a special mounting bracket (Figure 3) is available. This mounting support bracket is designed
for use with 3/8", 1/2" and 5/8" rebar or 1/2" schedule 40 PVC pipe.
Figure 3: Pit Support Bracket (Knuckles) - Top View
To install an ORION endpoint below a meter pit lid, follow these steps.
1.
Drive rebar or stake into the ground.
Drive rebar or st
ORION® Water Endpoint Integrated Pit Lid Hanger Installation Kit (ME and CE Endpoints)
ORION endpoints can also be installed in composite and plastic lids with an integrated hanger for AMR/AMI endpoints. An
installation kit for installing an ORION pit endpoint to the lid is available.
To install an ORION endpoint to a composite or plastic lid, follow these steps.
1.
Thread the lock nut onto the top of the ORION endpoint as shown.
2. Slide the endpoint in
Badger Meter ORION SE Remote Wall Mount Box Enclosure Kit (SE, ME and CE Endpoints)
The ORION Remote Wall Mount Box Enclosure Kit is for use with either the Recordall Transmitter Register (RTR) or Absolute
Digital Encoder (ADE) stepped tube and threaded tube ORION endpoint for remote mounting applications. The wall
mounted Remote Box Enclosure is designed for mounting ORION endpoints in indoor or outdoor environments and also
provides an en
ORION® Water Endpoint Figure 8: Remote Box Enclosure Mounting
2. Place the endpoint into the ORION Remote Box Enclosure as shown in Figure 9. To ensure maximum endpoint
performance, it is important to mount the ORION endpoint in the proper orientation, with the endpoint antenna up
and ORION endpoint IR communication port and wire down.
3. Make certain the flat side of the endpoint is facing the back of the enclosure, or toward the installer, when
insert
4. After the endpoint is mounted in the Remote Box Enclosure, loop the endpoint wire through the strain relief tab and
through the cut out on the bottom of the enclosure. If needed, gel splice connections can be made and kept inside
the Enclosure prior to mounting.
Figure 10: Endpoint Wire Positioning
5. Verify that the Remote Box Enclosure is properly positioned with the endpoint antenna up and the endpoint IR port
facing down. Secure
ORION® Water Endpoint Remote Installation Bracket Kit (SE, ME and CE Endpoints)
The following instructions are provided to properly install an ORION endpoint in any indoor, outdoor or pit application. Prior
to beginning the installation procedure, ensure that the following items are available.
•
Remote Installation Bracket Kit
•
Two customer-supplied screws
•
Screwdriver and drill
The Remote Installation Bracket securely mounts an ORION endpoint. Fo
2. Locate the small triangle aligned with the small hole on the bottom of the installation bracket. This triangle is used to
properly align the endpoint to the installation bracket.
Figure 13: Aligning Triangle
On the ORION endpoint, there is a small triangle printed on the lower side of the housing.
Figure 14: Housing Triangle
3. Align the two triangles and push the bracket and endpoint together.
Figure 15: Align Both Triangles
Triangl
ORION® Water Endpoint 4. With the installation bracket in one hand and the housing in your other hand, hold the bracket still and twist the
housing approximately 1/4 turn clockwise until it clicks and locks into place.
Figure 16: Bracket and Housing Connection
To install the endpoint assembly, follow these steps.
1.
Align the ORION endpoint and the installation bracket with the antenna facing upwards (Figure 17).
2. Using two customer-supplied screws,
Wiring a Universal Endpoint
Universal Endpoint Identification
The ORION Universal endpoint is available in a three-wire pit or remote endpoint configuration for connection to Sensus®
ICETM and ECR II, Neptune® ProRead and E-Coder™, Elster AMCo® ScanCoder ®, Hersey® and Metron Translator encoder
registers.
All ORION Universal endpoints are shipped from the factory pre-programmed and can be connected to any compatible
encoder. Electr