Allied Telesis AT-8224 Quick Install Manual

File Specifications

Brand: Allied Telesis
Category: Switch
Model: AT-8224 (Quick Install Manual), pr.5HY3DU6ANw
File Type: PDF
File Size: —
Pages: 38 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (38 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 14/05/2026).

Read Online

Read the Allied Telesis AT-8224 Quick Install Manual online using the built-in PDF viewer.

Key Pages of Document

Fast Ethernet Switches

Quick Install Guide PN 613-10810-00 Rev C ...

Copyright  2000 Allied Telesyn International, Corp.

960 Stewart Drive Suite B, Sunnyvale CA 94086, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. All ...

Electrical Safety and Emission Compliance

Statement Standards: This product meets the following standards. RFI Emission EN55022 Class A ! 1 WARNING: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. ! 2 Immunity EN50082-1 1997 ! 3 Electrical Safety TUV-EN60950, UL1950, CSA 950 ! 4 Laser EN60825 ! 5 Important: Appendix A contains translated safety statements for installi ...

Table of Contents

Electrical Safety and Emission Compliance Statement ......................iii Welcome to Allied Telesyn ......................................................................... vii Where to Find Web-based Guides ................................................................... vii Document Conventions ................................................................................... viii Contacting Allied Telesyn ................... ...

This guide contains instructions on how to install AT-8216FXL, AT-8224XL,

and AT-8288XL Series Fast Ethernet Switches. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation and technical information for all of our products. All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in pdf format ...

This guide uses several conventions that you should become familiar with first

before you begin to install the product. Note A note provides additional information. Caution A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data. Warning A warning indicates that performing or omitting a specific action may result in bodily injury. Contacting Allied Telesyn There are several ...

AT-8216FXL, AT-8224XL, and AT-8288XL Series Quick Install Guide

ix E-mail Support United States and Canada [email protected] Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands [email protected] United Kingdom, Sweden, Norway, Denmark, and Finland [email protected] Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Tel ...

If you know the name of a specific device driver that you need for an Allied

Telesyn device, you can download the driver by connecting directly to our FTP server at ftp://gateway.centre.com. At login, enter ‘anonymous’. Enter your e-mail address for the password as requested by the server at login. For Sales or Corporate Information Tell Us What You Think If you have any comments or suggestions on how we might improve this or other Allied ...

The AT-8216FXL, AT-8224XL, and AT-8288XL Series Fast Ethernet Switches

provide the following features: " Ethernet, Fast Ethernet, and Gigabit Ethernet connectivity " A small 1.5U high, 19-inch rackmountable enclosure " Built-in management functions for extremely flexible operation in a standalone configuration The switch models are listed in Table 1. Table 1 AT-8216FXL, AT-8224XL, and AT-8288XL Series Fast Ethernet Switches Models1 1. All models include ...

Installing the Switch

The following sections explain how to install the Fast Ethernet switch in your network. Note For information on site requirements, cabling specifications, and network topologies, refer to the AT-8216FXL/MT, AT-8216FXL/VF, AT-8216FXL/SC, AT-8224XL AT-8288XL/MT, and AT-8288XL/SC Installation Guide. This guide is available on the Allied Telesyn web site at www.alliedtelesyn/support/prd_libs.htm. Verifying the Package Contents Make sure ...

AT-8216FXL, AT-8224XL, and AT-8288XL Series Quick Install Guide

3 Reviewing Safety Guidelines Please review the following safety guidelines before you begin to install the Fast Ethernet switch. Laser Class 1 laser product. ! 6 Laser Do not stare into the laser beam. ! 7 Warning Electric Shock Hazard: To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened ...

Installing the Switch On a Table

The Fast Ethernet switch can be installed in a standard 19-inch rack or on a table or desktop. To install the switch in a rack, go to the section “Installing the Switch in a Rack” on page 6. To install the switch on a table, perform the following steps: 1. Remove all components from the shipping package and store the packaging material in a safe location. 2. Locate a level, secure surface for the switch. 3. If you pur ...

AT-8216FXL, AT-8224XL, and AT-8288XL Series Quick Install Guide

5 As power is applied to the switch, the Fault LED (shown in Figure 2) flashes as the switch runs a series of internal self tests. After the switch has finished running its self tests, the Fault LED will stop flashing and will remain off. Refer to the section “Switch LEDs” on page 9 for information on all of the System and Port LEDs. Figure 2 Fault LED 5. Connect the data cables, making s ...

Installing the Switch in a Rack

To install the Ethernet switch in a standard 19-inch rack, perform the following procedure: 1. Remove all components from the shipping package and store the packaging material in a safe location. 2. To prepare the switch, place it on a level, secure surface. 3. If you purchased an expansion module for the switch, install the module by following the instructions included with the module or by referring to the AT-8216FXL/MT, ...

AT-8216FXL, AT-8224XL, and AT-8288XL Series Quick Install Guide

7 6. Mount the switch in the rack using standard screws (not provided). Caution Air vents must not be blocked and must have free access to the room ambient air for cooling. ! 13 7. Apply AC power to the switch by plugging the power cord into the AC power connector on the back panel of the unit (shown in Figure 1) and plugging the other end into a power outlet. As power is applied to the switch ...

Setting Up for Local Management

If you are installing the switch in a TCP/IP environment or if you intend to manage the switch from a remote site, you must first assign an IP address to the switch using the Omega management software, which comes pre-installed on the switch. To connect a terminal to the switch and start an Omega management session, perform the following steps: 1. Connect a terminal to the RS232 connector on the front panel of the switch. ...

AT-8216FXL, AT-8224XL, and AT-8288XL Series Quick Install Guide

9 Switch LEDs Table 2 and Table 3 describe the functions of the LEDs on the Ethernet switch. Table 2 Power and Fault LEDs Table 3 Port LED Status For information on troubleshooting the switch, refer to the AT-8216FXL/MT, AT-8216FXL/VF, AT-8216FXL/SC, AT-8224XL, AT-8288XL/MT, and AT-8288XL/SC Installation Guide. LEDs State Description Fault Solid Red The switch or management software is malfu ...

AT-S24 Software Default Setting

Table 4 lists the default settings for the AT-S24 software that comes pre- installed on the Fast Ethernet switch. Table 4 Fast Ethernet Switch Default Settings Settings Default IP Address 0.0.0.0 Subnet Mask 0.0.0.0 Gateway Address 0.0.0.0 Get Community String public Set Community String private Trap Community String public Spanning Tree Protocol Disabled Bridge Priority 32768 Bridge Max Age Time 20 Bridge Hello Time 2 B ...