Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com © 2016 Acuity Brands Lighting, Inc. All rights reserved. 07/19/16

1 of 2 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION Always read complete installation instructions prior to installation! SAVE THESE INSTRUCTIONS WARNING! RISK OF SEVERE INJURY OR DEATH To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts, and other hazards: • Read all warnings and instructions included with and on the fixture box and all fixture labels. • Installation and service should be performed by a qualified licensed electrician. • Maintenance must be performed by a person familiar with the construction and operation of this product and any hazards involved. All applicable codes and ordinances must be followed. • Read this document before installing, servicing, or maintaining this equipment. These instructions do not cover all installation, service, and maintenance situations. If your situation is not covered, or if you do not understand these instructions or additional information is required, contact Acuity Controls. WARNING! RISK OF ELECTRIC SHOCK Before installing, servicing, or maintaining this equipment, follow these general precautions. To reduce the risk of electrocution: • Disconnect or turn off power before installation or servicing. • Make sure the equipment is properly grounded. • Make all electrical connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. WARNING! RISK OF FIRE To reduce the risk of fire: • Use supply conductors with a minimum operating temperature rating as specified. • Do not exceed maximum wattage, ratings, or published operating conditions. • Follow all manufacturer’s warnings, recommendations and restrictions to ensure proper operation. WARNING! RISK OF PERSONAL INJURY To reduce the risk of personal injury from cuts, abrasions: • Wear gloves and safety glasses at all times when installing, servicing or performing maintenance. WARNING! RISK OF PRODUCT DAMAGE Electrostatic Discharge (ESD) will damage electronic equipment. Do not attempt to open or service electronic equipment without proper ESD precautions. • Do not touch electronic components. ESD damage can occur. • Do not change or alter internal wiring or circuitry. ! ! ! ! ! Acuity Controls assumes no responsibility for claims arising out of improper or careless installation or handling of this product. Failure to follow any of these instructions could void product warranty. For a complete listing of product Terms and Conditions, please visit www.AcuityControls.com Installation Instructions - rPODB Wireless Switch

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com © 2016 Acuity Brands Lighting, Inc. All rights reserved. 07/19/16

2 of 2 The rPODB is a wireless switch that can be interconnected with the nLight® AIR network of wireless sensors and switches. rPODB Basic Overview Mounting Instructions/Important Notes INSTALLATION: Installation of the rPODB wall switch is simple, straight forward, and quick! Designed as truly “wire-free” with embedded wireless and battery power, installation requires zero wiring. Follow the simple steps below to perform the mechanical installation of the rPODB Wall Switch. • No wiring needed! • Install the rPODB into a single gang box just like your typical wall switch • Can be installed retainer first, or switch and retainer together • Check to make sure the rPODB is secure in retainer clip once installed • Screw down wall plate • DONE! Installation Instructions - rPODB Wireless Switch Battery Replacement: • Remove wall plate. • Carefully pry the retainer clip away from the module while pulling the rPODB from the retainer housing. - Using a flat head screwdriver, carefully pry the retainer clip away from the module. Use the tip of the screwdriver to pry against the tab on the module to help remove the rPODB module from the retainer clip. Otherwise, simply unscrew the retainer and module together from the gang box, then separate the module from the retainer. • Remove the battery cover with a short slide of the door, then lift battery cover off. - Note the arrow on the battery cover for direction to slide cover, also the ridges on the side for finger grips. • Remove old batteries and replace with new ones. • Reinstall battery cover by aligning the battery cover line with the line on the on the module, then slide shut. • Reinstall the rPODB Module into the retainer until secured • Reinstall wall plate • Done! ! CAUTION - To Reduce Risk of Fire. Use only Energizer L92 lithium batteries or any size AAA batteries of Type Zinc-Carbon, Alkaline, or Nickel-Cadmium CAUTION - The cell used in this device may present a fire or chemical burn hazard if mistreated. Do not disassemble, heat above 100°C (212°F) or incinerate. Dispose of used cell promptly. Keep away from children. 912-0018-001 Retainer Clip Alignment Line