Festo SRBG Operating Instructions
Read Online
Read the Festo SRBG Operating Instructions online using the built-in PDF viewer.
Text of the manual
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Operating instructions
(Original instructions)
8075401
2017-07a
[8075403]
Sensor box SRBG
English
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
Configuration
1.1 SRBG-…-C2-C2
4
2
5
6
1
7
8
3
1
Housing cover
2
Housing screws
3
Yellow LED, switching status indic
ation for solenoid valve
4
Caged spring terminal
5
Cable entry M20 x 1.5 for system
connection
6
Cable entry M12 x 1.5 for solenoid
valve connection
7
Inductive dual sensor
8
Green LED, power supply indicator
(only for SRBG-C1-N-1-P-C2-C2)
yellow LED, switching status indic
ation
Fig. 1
1.2 SRBG-…-M12
3
1
2
1
Green LED, power supply indicator
(only for SRBG-C1-N-1-P-M12)
Yellow LED, switching status indic
ation
2
Inductive dual sensor
3
M12 plug connection
Configuration of SRBG-…-M12-M12 (� Chapter 4.2)
Accessories � www.festo.com/catalogue.
2
Safety
The sensor box is intended for recording, electrical feedback and optical display of
the end positions of drives.
Appropriate for operation are semi-rotary drives with a mechanical interface in
accordance with VDI/VDE Directive 3845.
– The product may only be used in its original status.
– Only use the product if it is in an excellent technical status.
– Observe the product labelling.
– If cable connector the O-ring supplied is not necessary.
3
Function
The sensor box SRGB detects the end position of the drive with the help of the
SASF position indicator as an activating element. Inductive sensors of the sensor
box detect the metallic actuating elements on the position indicator in a
non-contact manner. These actuating elements are fixed at an offset of 90 ° and
are suitable for anti-clockwise and clockwise drives with a 90 ° or 180 ° rotation
angle.
4
Installation and commissioning
Warning
Electric voltage.
Injury due to electric shock.
� Switch off the power supply before opening the device.
Note
Installation and commissioning should only be conducted by qualified personnel.
4.1 Mechanical
Mount the sensor box to the fastening interface of the semi-rotary drive. Use M5
mounting screws. The mounting holes in the sensor housing ensure that no adjustment
is necessary when mounting the sensor. Attach the SASF position indicator to the drive
shaft. Use M6 screws. Use a spacer disc, dependent on the wave height. When mount
ing is complete, attach the stopper cap and identification stopper to the position indic
ator.
1
2
3
4
1
Stopper cap
2
Identification stopper
3
Actuating elements
4
Spacer disc
Fig. 2
4.2 Electrical
Note
Inappropriate cables or incorrect installation reduce the degree of protection
of the sensor box.
Note
The product is suitable for industrial purposes only. This product can generate
high frequency interference, which may make it necessary to implement interfer
ence suppression measures in residential areas.
Note
Coupling powerful electromagnetic fields of 3 V can cause the product to mal
function at an operating frequency between 500 and 600 kHz.
1. Loosen the housing screws 2 on the housing cover. Remove the housing cover.
2. Screw the cable connector into the cable entry. Guide the electric connecting
cable through the cable connector to the terminal block.
– Conductor cross section: 1.5/2.5 mm2 (flexible/rigid).
3. Seal unused cable entries with blanking plugs.
4. Wire the connections (� product labelling).
5. Place the housing cover in position and tighten the 4 housing screws 2.
Connection SRBG-C1-N-1-AS-M12-M12 / SRBG-…-M12
1
2
3
4
5
6
1
SRBG-…-M12-M12:
Solenoid valve connection
2
SRBG-…-M12-M12:AS-i connection
SRBG-…-M12: sensor connection
3
Yellow LED,
witching status indication
4
Green LED, power supply indicator
5
Switching status indication
6
SRBG-…-M12-M12: Switching
status indication for solenoid valve
Programming instructions
Adress
00 preset, can be changed via bus master or programming units
IO code
D
Ident. code
A
ID1 code
7
ID2 code
E
Data bit
Bit
Function
D0
Valve status / (0=valve off, 1=valve on)
D1
Valve error1) / (0=wire break/short circuit; 1=no error)
D2
Switching output sensor 12) / (0=attenuated; 1=uncushioned)
D3
Switching output sensor 22) / (0=attenuated; 1=uncushioned)
Parameter bit
Bit
Function
P0
Watchdog (0=inactive; 1=active)3)
P1
Switching element function sensor 24) / (0=N/O contact; 1= N/C contact)
P2
Switching element function sensor 14) / (0=N/O contact; 1= N/C contact)
P3
Not used
1)
Check only with activated valve (D0=1)
2)
Applies to N/C function (P2/P3=1; preset), reversed behaviour with N/O function (P2/P3=0)
3)
Watchdog active: Valve voltage drops in the event of AS-Interface communication error
4)
Presetting: N/C contact
5
Maintenance and care
If used as intended, the product is maintenance-free.
6
Technical data
Position indicator SASF
SASF-S2-B-F-A34
SASF-S2-B-F-A56
Ring diameter
[mm]
� 65
110
Circlip height
[mm]
� 6
7
Ambient temperature
[°C]
-25 … 80
Mechanical data
Shaft diameter
[mm]
� 58
90
Shaft height
[mm]
20/30
30/50
Mounting hole pattern
[mm]
30x80
30x130
Material
Housing, Spacer disc, Identification
stopper
PBT
Stopper cap
PP
Mounting screw, Actuating lug
high-alloy stainless steel
Hinweis
The plastic housings of the position indicator are made of conductive material
and must be integrated into a suitable earthing concept.
Hinweis
The position indicator SASF consists of conductive plastic material.
� Use in potentially explosive areas possible, as there is no static charge.
SRBG-…-M12-M12
Switching output
AS-Interface
Switching element function
Programmable N/O contact/ N/C contact
Max. switching frequency
[Hz]
100
Idle current
[mA]
35
Operating voltage range DC
AS-Interface
[V]
26.5 … 31.6
Load voltage range DC
[V]
21.6 … 26.4
Current consumption with load
voltage from AS-Interface and
load voltage connection
[mA]
100
Protocol
AS-Interface specification V3.0 Required master spe
cification ≥ V2.1 Slave type A/B slave
Device-specific diagnostics
Wire break/short circuit in valve
Addressing range
1A … 31A (0) / 1B … 31B
Reverse polarity protection
for all electrical connections
Sensor connection
M12 x 1, plug, 4-pin
Ambient temperature
[°C]
-25 … 70
Storage temperature
[°C]
-25 … 70
Degree of protection
IP67
Shock resistance
Shock test with severity level 2 to FN 942017-5 and
EN 60068-2-27
Vibration resistance
Transport application test with severity level 2 to FN
942017-4 and EN 60068-2-6
CE marking
in accordance with EU EMC Directive
Approval
c UL us (OL) RCM compliance mark
Housing
PBT
M12 plug, Screws
high-alloy stainless steel
Note on materials
RoHS compliant / Contains paint-wetting impairment
substances
Mounting position
any
SRBG-…-M12/SRBG-…-C2
-P
-ZU
-ZC
Switching output
PNP
non-contacting, 2-wire
NAMUR
Switching element function
N/O contact
N/O contact
N/C contact
Max. switching
frequency
[Hz]
500
500
3000
Operating voltage range
[V DC]
10 … 30
6 … 60
8.2
Max. output current DC
[mA]
100
100
3
Voltage drop
[V]
3
6
-
Idle current
[mA]
25
-
-
Residual current
[mA]
0.5
1
-
Minimum load current
[mA]
-
4
-
Reverse polarity protection
for all electrical connections
Switching status indication
Yellow LED
Power supply indicator
Green LED
-
-
Sensor connection
SRBG-…-M12
M12 x 1, plug, 4-pin
Electrical connection
SRBG-…-C2
spring-loaded terminal
Ambient temperature
[°C]
-25 … 70
-25 … 70
-25 … 100
Storage temperature
[°C]
-25 … 70
-25 … 70
-40 … 100
Degree of protection
IP67
Shock resistance
Shock test with severity level 2 to FN 942017-5 and
EN 60068-2-27
Vibration resistance
Transport application test with severity level 2 to FN
942017-4 and EN 60068-2-6
CE marking
in accordance with EU EMC Directive
�
�
in accordance
with ATEX
Approval
c UL us (OL) RCM compliance mark
Housing
PBT
M12 plug, Screws
high-alloy stainless steel
Note on materials
RoHS compliant / Contains paint-wetting impairment sub
stances
Mounting position
any