Relay switching insert 2-gang

Relay switching insert 2-gang Order no.: 5404 00 Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Always disconnect befor

Relay switching insert 2-gang

5 Operation with 1-gang push-button top Switch load With the 1-gang push-button top, output a2 switches depending on the switching state of output a1. ■ Press push-button. Output a1 and a2 switch on and off. Extension unit operation Operation using 2-wire extension, push-button or rotary dimmer extension correspond

Relay switching insert 2-gang

– Press timer with display and the button ƞ and Ɵ simultaneously for longer than 4 seconds. Run-on time The run-on time for output a2 is set at the insert as described (see Setting the time function/run- on time). 7 Operation with Bluetooth motion detector During movement, the motion detector switches output a1 d

Relay switching insert 2-gang

Connecting and fitting the device Figure 1: Connection diagram with optional extensions (1) Button TEST (2) Display LED and connection socket for cover (3) 2-wire extension (4) 3-wire extension/rotary dimmer extension (5) Push-button, NO contact Figure 2: Clampable conductor cross-section For protection, only the c

Relay switching insert 2-gang

The load at both outputs can be switched by briefly pressing the TEST button (1) (switch- ing states: a1 on a2 off, a1 off a2 on, a1 and a2 on, a1 and a2 off). Set time function/run-on time ■ Press the TEST button (1) for longer than 4 seconds. LED (2) lights up in the colour of the set time, see table. LED signal