Thank You For Purchasing A

KickAss® Fridge / Freezer Features: Please ensure all safety and operational instructions are read carefully to get the maximum benefit from your new fridge. Digital electronic thermostat with LED temperature display Reliable refrigeration system with Secop compressor Efficient electronic technology, low energy consumption Multi-voltage system (DC 12-24 Volt) and (AC 220-240 Volt) Adjustable low voltage battery protection IMPORTANT SAFETY SYMBOLS Warning! - Safety Directive Failure to observe this directive could lead to serious injury. Caution! - Safety Directive Failure to observe this directive could lead to injury or damage to the appliance. Note! - Important Information Failure to observe this note may lead to damage to the appliance or impede performance. 1

TECHNICAL DATA (STANDARD CONFIGURATIONS)

Operating voltage 12 o 24 VDC Refrigerant gas and charge R134a 0,044 kg - CFC Free (CO2 eq. 0,063 t) Dimensions 260 x 440 x 695 (mm) Net weight 18 Kg Installed power 45 Watt SPECIFICATIONS PRODUCT FEATURES Slide out drawer Drawer latch Soft touch controls Power connection Compressor cooling vents 3

KickAss DRAWER refrigerators have been designed and constructed exclusively for

recessed installation and installation that is in compliance with standard dimensions. The refrigerator must always be in a horizontal position, with the compressor’s rubber feet at the bottom. The compressor is capable of functioning at angles of up to 30°. The compressor can become damaged with any higher inclinations. Ventilation It is extremely important for the compressor/condensing unit located behind the refrigerator to be well ventilated so that the fresh air can enter at the bottom and pass behind the refrigerator, with the hot air being allowed to escape from the top or sides. Electrical Connections • Before turning on the appliance, check to make sure that the voltage of the electrical system and/or battery complies with that which is indicated on the unit’s data plate. • Connect the refrigerator directly to the battery or to the relative main switch and make sure that the system is equipped with an electric device that’s capable of protecting the circuit against possible overcurrents. • The product is supplied with a 10 A fuse. A separate switch that simultaneously disconnects the power cables must be installed upstream from the refrigerator. Check to make sure that this switch supports the 10 A current load. SIZE OF THE ELECTRICAL CABLES Always use cables of a suitable cross-section. The minimum cross-sections are listed in the table below: Cross- section in mm² AWG section Max 12 V cable length m/ft Max 24V cable length m/ft 2.5 13 2.5/8 5/16 4 11 4/13 8/26 6 9 6/19 12/39 10 8 10/33 20/66 For system protection, the fuse must be installed in the positive wires (+) as close as possible to the battery. We recommend using 15 A fuses for 12 V and 7.5 A fuses for 24 V. If using a main switch, it must be able to withstand a minimum current of 20 A. Avoid extra junctions in wiring to prevent voltage drops that can influence battery protection settings. 4

TEMPERATURE ADJUSTMENT SETTINGS

TEMPERATURE REGULATION WITH DIGITAL DISPLAY 4 3 2 1 DISPLAY FUNCTIONS • Switching on: Press and hold the 1 button for 4 seconds. • Shut-down (Stand-By): Press and hold the 1 button for 4 seconds. • Internal temperature adjustment buttons 2 and 3. • Access to programming menu [Pro]. TEMPERATURE SETTING Switch on the refrigerator, set the desired temperature using the 2 button to increase or 3 to decrease the temperature, which will be saved automatically. MENU FUNCTION [PRO] The Pro menu allows for changes to the following data: offset 1, offset 2, offset 3, battery protection (For offset information see page 7). To access the Pro menu, press the 2 and 3 buttons simultaneously for 4 seconds. The message will then appear on the digital display. Press the 1 button to confirm entry into the menu. The offset1 value will appear. This value can be changed from +8 to -8 using buttons 2 and 3. Press 1 to confirm the new data entered and go to setting for the next parameter. The offset2 value will appear. This value can be changed from +8 to -8 using buttons 2 and 3. Press 1 to confirm the new data entered and go to setting for the next parameter. The offset3 value will appear. This value can be changed from +8 to -8 using buttons 2 and 3. Press 1 to confirm the new data entered and go to setting for the next parameter. The figure shown, or or , refers to the level of battery saving set. The value can be modified using button 2 or 3. Press 1 to confirm the new data entered and go to setting for the next parameter. The figure shown or refers to the selection of the temperature scale, Celsius or Fahrenheit, the selection of the factory setting is in Celsius, the value can be changed by pressing the button 2 or 3. To exit from the Pro menu, wait a few seconds until the display shuts down. Data will be saved automatically. 5 all-guides com

After a few hours of refrigeration system operation, insert a digital thermometer (not included)

inside the compartment in the position where you wish to have a more precise temperature and check that the temperature indicated on the display coincides with the temperature read on the digital thermometer. If it does not coincide, change the Offset related to the temperature you wish to reach inside the compartment until the temperature read on the display coincides with the temperature indicated on the digital thermometer. Offset Temperature Interval 1 T ≥ -6°C 2 -12°C ≤ T ≤ -7°C 3 T ≤ -13°C Data which is used to align the temperature shown on the display with the actual internal temperature. Adjustment for each offset can vary from -8 / +8. POWER OPTIONS LOW VOLTAGE PROTECTION In order to prevent excessive battery depletion, a protection device shuts off the compressor in case of insufficient voltage and turns it back on when the voltage in the system increases after the batteries have been charged. Battery Protection Battery level Digital Display 12 Vdc 24 Vdc Cut-Out Comp. off Cut-In Comp. on Cut-Out Comp. off Cut-In Comp. on Low 9.6 10.6 21.3 22.7 Medium 11.1 12.1 22.3 23.7 High 11.8 12.8 24.3 25.7 7

DISPLAY ERRORS TABLE

TROUBLESHOOTING Error Cause E1 Insufficient voltage (Volts below the cut-in / cut-out value) E2 Defective fan E3 Control unit error or compressor blocked E4 The refrigeration system is too loaded with gas and/or the compressor is running at a number of revolutions that is too low E5 Room temperature is too high E6 Internal temperature sensor error Defect Possible cause Intervention The refrigerator does not cool, the compressor will not start. No electrical power. Battery in poor condition. Faulty thermostat. Defective electronic control unit. Check to make sure that the electronic control unit is receiving sufficient power and voltage; check the fuse. Verify that the internal lighting is working and that the compressor is receiving power. Check the cables, lugs and connectors. Verify that the battery is charging properly. Check the thermostat: Bridge T - C with a separate cable. If the compressor will not start, its electronics are probably defective. Replace. If the compressor starts up with the bridge, the thermostat is defective. Replace the thermostat. The compressor only performs brief attempts at starting up. There is insufficient voltage or else a drop in voltage during the attempt to start. The protection device is activated. The Batteries are drained. Check the cables and connections; remove any traces of oxidation or corrosion. Charge the batteries, start the motor or connect the battery charger. The compressor functions but doesn’t cool. Loss of refrigerant through the evaporator or the tubing. Tubing clogged. Carry out a leak check and repair any leaks, drain and refill the proper amount of R134a refrigerant. (This operation must be carried out by a qualified technician.) The compressor runs for a long time but doesn’t cool properly (reduced efficiency). Insufficient ventilation, the condensation unit is overheating. The fan is not working properly. There is too much frost on the evaporator. The door does not close properly and lets in warm, moist air. The condenser is blocked by dust. Increase the ventilation. Replace the fan. Defrost the unit. Correct the position of the door and check the gasket. Clean the condensing unit. GENERAL TROUBLESHOOTING 8

The fuse blows.

The wrong fuse is being used. Defective electronic control unit. Check the fuse: see table in section 4.4. Replace the electronic control unit. The compressor is operating intermittently. Battery low or electrical cables in poor condition. Check wiring conditions, examining for loose connections, rust or corosion. If wiring needs to be replaced, see the manual for correct sizing. If wiring is in good condition, check battery function and replace if in poor condition. The compressor never stops (correct fridge performance) Incorrect thermostat connection on the electronic control unit. Thermostat broken. Condensation is not working properly, evaporator cools but not enough to cause the thermostat to stop the compressor. Rotate the thermostat to off position. If the refrigerator continues to function, then there is continuity on the control unit. Correct the problem on thermostat connections (make sure the bridge is present on C and P and not on C and T on the electronic control unit). Rotate the thermostat to off position. If the compressor switches off but it is impossible to regulate temperature, replace the thermostat or recharge the cooling system. The compressor never stops (poor fridge performance) Environment very hot + insufficient ventilation or little gas in the refrigerant circuit. Check ventilation. The compressor must be installed in a well-ventilated location. If possible, remove the refrigerator from the installation hole. If the refrigerator operates better, improve ventilation, consulting the manual for correct installation. If ventilation is instead optimal, check for the presence of gas in the system, contacting a specialised technician. 9

THANK YOU FOR CHOOSING

KickAss® is committed to providing you with the most up to date product information. As printed material is harder to update we have created an online user guide portal including videos, user guides and product tips so you can view or download the latest product information at any time. This also helps to save our environment which we are committed to just as much as we are committed to our customer service. To get started with this product, please visit and search for your SKU code ONLINE USER GUIDES SCAN QR CODE USERGUIDES.KICKASS.COM.AU all-guides com

This product is warranted for 3 years from the date of purchase. In Australia, our

goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Warranty does not cover products that have not been used in accordance with the KickAss® user guide or are outside the warranty terms and conditions. AUSTRALIAN DIRECT PRODUCT QUALITY QUESTIONS AND COMMENTS Customer Support For any technical or warranty enquires please visit our customer service portal at: warranty.kickass.com.au Please visit us at kickass.com.au or email us at [email protected] This KickAss product comes with a 3 year warranty on the whole unit, for your peace of mind. In the unlikely event this product fails when used according to our user guide, we will either repair or replace it. For full warranty terms and conditions on this product, please see the user guide at: userguides.kickass.com.au WARRANTY INFORMATION