Interface BlueDAQ BSC4D Quick Start Manual
Text of Interface BlueDAQ BSC4D Quick Start Manual
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555
www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
BlueDAQ QUICK START GUIDE
Software for use with models
BSC4D, BSC8D, BX8 and 9330
BlueDAQ
Software
Issue: 15-258 Revision A
Quick Start Guide
www.interfaceforce.com
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
2
1. Please follow these instructions carefully. DO NOT connect the amplifier to the
PC until instructed to do so. The BlueDAQ PC software is included on a USB
Flash Drive with the amplifier or can be downloaded from
www.interfaceforce.com
2. Install the software by d
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
3
9330 Driver installation
When the device is connected in Communication mode for the first time, Windows will ask for
a driver directory. The installation process is described below. The driver is located on the USB
Flash drive supplied with the 9330. The Flash drive
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
4
In the dialogue window
“Hardware installation”
click “Continue installation”.
The driver was installed successfully.
Click “Finish”.
4. Once windows is finished installing the device navigate to Device Manager and
check for a new USB Serial Port (COMX) w
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
5
BSC8D installs as a Data Acquisition Device
BX8
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
6
5. Run BlueDAQ from the start menu. After the program launches click “ADD
CHANNEL”
6. In the Add Channel dialog box
a. Click Devicetype drop-down and select BSC4, BSC8, BX8, or BSC2
(9330)
b. Click the Device dropdown box and select the device, select the COM P
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
7
BSC8 has a slightly different add channel box. Select Dev1 instead of Com port.
Please remember to open the needed amount of input channels.
7. Each channel must now be scaled using the “SCALING” dialog box. Each channel
must be scaled independently. If the BSC
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
8
8. Example scaling using Load Cell / BSC8 Digital Bridge Amplifier Calibration
Certificate”
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
9
Press Calculate to scale and then OK/Set to
save
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
10
9. Example scaling a channel using model WMC-100 load cell with 100 lbf capacity
and 1.9587 mV/V output. After entering the values into the dialog box you must
click “Calculate” and then “OK/Set”.
10. Once each channel has been scaled the software is ready
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
11
11. For Six-Axis sensors only. Click “Special Sensor”
12. Select sensor type “Multidimensional sensor” and click OK
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
12
13. Select Add Sensor. You will be prompted to map the program to the location of
the Matrix.
14. Select Change Dir.. and select the folder containing the calibration matrix. This
folder is located on the USB flash drive and will be labeled with the transducer
ser
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
13
15. Click “Auto-Rename Channels” and then “OK Enable this sensor”
16. Add the distance offsets for geometry correction. The origin is at the top center
surface of the sensor. For example, if the loads are applied 2” from the top
surface then the Z-Directi
Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 www.interfaceforce.com ● Email: [email protected] ● ORDER TOLL-FREE 800.947.5598
14
19. If you experience an issue where your Model BSC4 will not properly install, please
refer to the below notes that could be helpful.
a. The BSC4 uses a USB chip manufactured by FTDI and uses the COM
(i.e. VCOM) software model.
If you're using Windows 8, here is t