IVAR SAP-35E Instruction Manual

File Specifications

Brand: IVAR
Category: Water System
Model: SAP-35E (Instruction Manual), prsJn8oVIosVM
File Type: PDF
File Size: —
Pages: 16 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (16 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 29/03/2026).

Read Online

Read the IVAR SAP-35E Instruction Manual online using the built-in PDF viewer.

Key Pages of Document

L'installazione e la messa in opera del sistema SAP vanno effettuate esclusivamente da personale qualificato in accordo con i regolamenti nazionali e/o i

relativi requisiti locali. Nel caso l'operatore debba effettuare interventi che comportano il pericolo di contatto con il fluido di caldaia, è opportuno che utilizzi i dispositivi di protezione individuale adeguati. È importante seguire attentamente le istruzioni fornite per preve ...

[kW] (*) Valvola miscelatrice Ricircolo

N. piastre scambiatore Circolatore primario Pompa di ricircolo Sensore VFS [l/min] SAP-35E 35 85 - - 20 Yonos Para PWM 25/7 - 2-40 SAP-45E 45 110 - - 30 Yonos Para PWM 25/7 - 5-100 SAP-60E 60 147 - - 50 Yonos Para PWM 25/7 - 5-100 SAP-80E 80 195 - - 50 Stratos Para 25/1-8 - 5-100 SAP-100E 100 244 - - 50 Stratos Para 25/1-12 - 5-100 SAP-35RE ...

Messa in funzione

⚠ Attenzione. Assicurarsi che le valvole a sfera di intercettazione siano tutte completamente aperte prima di mettere in funzione il produttore sanitario. La messa in servizio della centralina di controllo deve essere effettuata esclusivamente da personale qualificato per evitare di arrecare danno ai componenti dell'impianto e/o a cose e persone, secondo il libretto di istruzioni del regolatore allegato a SAP. SAP co ...

The installation and commissioning of the SAP unit must be exclusively performed by qualified personnel in accordance with the national guidelines and/or

the relative local requirements. If the operator is required to perform any interventions which could pose a risk of direct contact with the boiler fluid, he/she is advised to use adequate personal protection equipment (PPE). It is important that the provided instructions be followe ...

DHW flow rate

[l/min] (*) Output [kW] (*) Mixing valve Recirculation N. heat exchanger plates Primary pump Recirculation pump VFS sensor [l/min] SAP-35E 35 85 - - 20 Yonos Para PWM 25/7 - 2-40 SAP-45E 45 110 - - 30 Yonos Para PWM 25/7 - 5-100 SAP-60E 60 147 - - 50 Yonos Para PWM 25/7 - 5-100 SAP-80E 80 195 - - 50 Stratos Para 25/1-8 - 5-100 SAP-100E 100 244 - - 50 Stratos Para 25/1-12 - 5-100 SAP-35RE 35 85 -  2 ...

Warning. Make sure all the shut-off ball valves are fully open before operating the fresh water station. The set-up of the controller must be performed exclusively by

qualified personnel in order to prevent damages to the system and/or personal injury, according to the instruction manual included in SAP package. SAP starts working as soon as it gets power-supplied. At the first start up, the controller must be set-up by enterin ...

Die Installation und Inbetriebnahme des SAP-Systems darf ausschließlich von qualifiziertem Personal entsprechend der nationalen Vorschriften bzw. örtlich

geltender Bestimmungen durchgeführt werden. Sind Arbeiten erforderlich, bei denen Berührungsgefahr mit dem Kesselmedium besteht, sollte die entsprechende persönliche Schutzausrüstung verwendet werden. Die Anweisungen und Hinweise müssen beachtet werden, um etwaige Sach- und P ...

[kW] (*) Mischventil Zirkulation

Plattenanzahl Wärmetauscher Umwälzpumpe Primärseite Umwälzpumpe VFS-Sensor [l/min] SAP-35E 35 85 - - 20 Yonos Para PWM 25/7 - 2-40 SAP-45E 45 110 - - 30 Yonos Para PWM 25/7 - 5-100 SAP-60E 60 147 - - 50 Yonos Para PWM 25/7 - 5-100 SAP-80E 80 195 - - 50 Stratos Para 25/1-8 - 5-100 SAP-100E 100 244 - - 50 Stratos Para 25/1-12 - 5-100 SAP-35RE ...

Achtung. Vor Inbetriebnahme des Warmwasserbereiters sicherstellen, dass die Absperrkugelhähne vollständig geöffnet sind. Die Inbetriebnahme der Steuerung

muss durch Fachpersonal entsprechend der beiliegenden Steuerungsanleitung erfolgen, um Schäden an Anlagenteilen oder Gegenständen bzw. Verletzungen zu vermeiden. Das SAP-Modul nimmt sofort nach Herstellung der Stromversorgung den Betrieb auf. Die Steuerung muss ...

SAP-60(R)(E), SAP-80(R)(E), SAP-100(R)(E)

SAP-30M(R)(E) SAP-40M(R)(E) SAP-50M(R)(E), SAP-70M(R)(E), SAP-90M(R)(E) Fig. 3 SAP-30(R)(E), SAP-30M(R)(E) SAP-45(R)(E), SAP-40M(R)(E) SAP-60(R)(E), SAP-80(R)(E), SAP-100(R)(E), SAP- 50M(R)(E), SAP-80M(R)(E), SAP-90M(R)(E) Fig. 4 ...

Yonos Para 25/7 PWM

Stratos Para 25/1-8 Stratos Para 25/1-12 ZRS 12/2 ZRS 12/6 Fig. 5 Fig. 6 ...

G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C]

40 22.0 21.4 29.5 18.2 36.0 16.3 41.9 15.0 47.5 14.0 52.9 13.2 58.2 12.5 63.4 11.9 68.5 11.5 45 - - 21.2 24.0 28.2 20.4 34.0 18.2 39.4 16.7 44.4 15.5 49.2 14.5 54.0 13.8 58.6 13.1 50 - - - - 20.6 26.5 27.1 22.5 32.5 20.1 37.4 18.4 4 ...

G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C] G2 [l/min] T1out [°C]

40 20.7 20.9 27.7 17.8 33.6 15.9 39.1 14.5 44.3 13.5 45 - - 20.0 23.5 26.4 19.9 31.8 17.7 36.8 16.2 50 - - - - 19.4 26.0 25.5 22.0 30.4 19.5 60 - - - - - - - - 18.7 30.9 40 22.2 22.9 30.0 20.2 36.6 18.5 42.7 17.4 48.6 16.6 45 - - 21.2 25.4 28.2 22.2 34.2 20.3 39.6 19.0 50 - - - - 20.5 27.8 26.9 24.2 32.3 22.1 60 - - - - - ...

300459-10-2016 16/16 Notes .................................................................................................................................................................................................................................................................................................................... .......................................................................................................................... ...

Related Devices for IVAR SAP-35E:

EQUICOMPACT
IVAR EQUICOMPACT Instruction manual
11.06.2026 8 pages

300451-04-17 Manuale di istruzioni Instruction manual EQUICOMPACT User handbook for the IVAR EQUICOMPACT Control Unit. This guide describes installation procedures, energy usage, network configuration, product maintenance.

MULTIMIX-C
IVAR MULTIMIX-C Instruction manual
17.05.2026 16 pages

MULTIMIX-C IT - Manuale di istruzioni EN - Instruction manual 300427-7-2016 Product documentation for the IVAR MULTIMIX-C Control Unit. This guide provides information on dimensions and layout, detailing setup, component overview, usage procedures.

SUPERAC 93
IVAR SUPERAC 93 Instruction booklet
15.04.2026 42 pages

I.VAR INDUSTRY S.r.l. Via S. Pierino, 4 (Z.A.I.) - 37060 Trevenzuolo – VERONA - Italy Telefono 045/6680082 - Telefax 045/6680051 - P.IVA 02835480233 e-mail: i Technical reference manual for the IVAR SUPERAC 93 Boiler. The document contains product maintenance, interface navigation, supported accessories.

SFWC
IVAR SFWC Installation and operating instructions manual
17.07.2026 36 pages

Fresh Water Controller SFWC Installation and operating instructions Read carefully before installation, commissioning and operation all-guides com User support guide for the IVAR SFWC Controller. This manual describes setup, usage, and maintenance procedures, installation procedures, performance optimization.

IC-BOX 1
IVAR IC-BOX 1 Instruction manual
09.08.2026 16 pages

300350-04-12 IC-BOX Manuale di istruzioni Instruction manual Manuel d’utilisation Bedienungsanleitung Manual de instrucciones Handleiding Comprehensive setup guide for the IVAR IC-BOX 1 Controller. This documentation explains configuration and internal layout, system configuration, software installation.

UNIMIX
IVAR UNIMIX Manual 
30.08.2026 19 pages

UNIMIX IVAR_UNIMIX_E_DE.indd 1 05-11-2008 10:04:07 User reference manual for the IVAR UNIMIX Music Mixer. The document explains error handling, power requirements, safety precautions, replacement parts.

IS-BOX
IVAR IS-BOX Instruction manual
10.04.2026 8 pages

300349-04-12 IS-BOX Manual instructiuni Instruction Manual Complete usage guide for the IVAR IS-BOX Plumbing Product. It provides guidance on error handling, interface navigation, technical overview, operating conditions.

PRV
IVAR PRV Instruction manual
08.06.2026 8 pages

1/8 300371-04-17 Manuale di istruzioni Instruction manual Manuel d’utilisation Bedienungsanleitung Manual de instrucciones Handleiding PRV User instructions for the IVAR PRV Control Unit. It provides technical information on troubleshooting, operating guidelines, device reset instructions.

Water System: Frequently Requested PDF Instructions

DELUXE PLUS
Premier DELUXE PLUS Installation, operation and maintenance manual
06.05.2026 28 pages

Product operation manual for the Premier DELUXE PLUS Water Filtration Systems. The manual guides users through maintenance schedule, product specifications, installation, installation support.

864026
Zanussi 864026 Technical data
14.05.2026 2 pages

ZANUSSI P R O F E S S I O N A L EXTERNAL REVERSE OSMOSIS FILTER max - bar 10 10 min - bar 2 2 Pressure max - °C 30 30 min - °C 2 2 Tempera Product operation guide for the Zanussi 864026 Water System. This manual explains component replacement, adjustment procedures, hardware setup, wiring setup.

OASI Series
TECNICOMAR OASI Series Instructions for the installation, use and maintenance
05.08.2026 38 pages

l;t!7 .. ' Mod. PO07A07 Rev. 7 Tecnicomar SpA Test Certificate for Watermakers Certificate Nr. Ul - D^tet 4t!L/24!f Serial Number: 201117097 Crrstomer: f,IXALTO User support manual for the TECNICOMAR OASI Series Water System. The manual provides technical details on power management, control functions, application scenarios.

S-54 Cartridge EV9720-06
Everpure S-54 Cartridge EV9720-06 Specification sheet
10.07.2026 2 pages

B E N E F I T S A P P L I C A T I O N / S I Z I N G I N S T A L L A T I O N T I P S O P E R A T I O N T I P S S-54 Cartridge Delivers premium quality water fo Maintenance instructions for the Everpure S-54 Cartridge EV9720-06 Water System. It explains installation, setup, and installation support, safety precautions, system configuration.