Seaward Live Line Tester Operating Instructions

Specifications

Brand: Seaward
Category: Test Equipment
Model: Live Line Tester (Operating Instructions)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Seaward Live Line Tester Operating Instructions online using the built-in PDF viewer.

Text of the manual

LLT Live Line Tester

Operating Instructions Bracken Hill South West Industrial Estate Peterlee Co. Durham SR8 2SW ENGLAND Tel: +44 (0)191 586 3511 www.seaward.co.uk [email protected] [email protected] Part Number 114A556 Revision 1 © 2007 Seaward Electronic Ltd 2 Specifi cation 3 Maintenance Clean only with a dry cloth; do not use solvents. Before use, ensure unit is clean and dry; visually inspect test terminals and case. Any damage must be rectifi ed to preserve user safety. 4 Service and Calibration To maintain the specifi ed performance, the instrument must be verifi ed at regular intervals by either the manufacturer or an authorised Seaward Service Agent. We recommend a calibration period of one year. For help or advice on Service and Calibration contact: Service Department Seaward Electronic Bracken Hill South West Industrial Estate Peterlee Co. Durham SR8 2SW England Tel: +44 (0) 191 587 8739 / +44 (0)191 587 8737 Email: [email protected] Web: www.seaward.co.uk Maximum Working Voltage Threshold Voltage Operating Current Indicator Handle Length Overall Length Handle Diameter Probe Tip Length Hand Guard Height Distance from Uninsulated Probe Tip to Handguard Uninsulated Contact Electrode Length Contact Electrode Diameter Lead Length between Probes Construction Compliance 1100V DC 200V AC / 300V DC <10mA DC at Max Working Voltage High Intensity LED with Polarising Filter 153mm 195mm 20mm 38mm 27mm Over Full Circumference 138mm 5mm 3mm 1.7m Double Insulated Cable High Impact, Total Encapsulation BS EN 61243-3:1999 Voltage Class B

Limited Warranty & Limitation of Liability

SEAWARD Electronic Limited Guarantees this product to be free from defects in material and workmanship under normal use and service for a period of 1 year. The period of warranty will be effective at the day of delivery. © Copyright 2007. All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from SEAWARD Electronic Limited. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development SEAWARD Electronic Limited reserves the right to alter the equipment specifi cation and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifi cally referred to as an inclusion within such contract. DECLARATION OF CONFORMITY As the manufacturer of the apparatus listed, declare under our sole responsibility that the product: LLT LIve Line Tester To which this declaration relates are in conformity with the relevant clauses of the following standard: BS EN 61243-3:1999 Voltage Class B Two pole BS EN 61326:1998 Electrical equipment for measurement, control and laboratory user-EMC Requirements Performace: The instrument operates within specifi cation when used under the conditions in the above standards EMC and Safety Standards. The product identifi ed above conforms to the requirements of Council Directive 89/336/EEC and 73/23 EEC. Seaward Electronic Ltd. is registered under BS EN ISO9001:2000 Certifi cate No: Q05356. 1 Important Information These operating instructions are intended for the use of adequately trained personnel. Before use, ensure that the Live Line Tester is clean and dry; visually inspect all parts. Any damage must be rectifi ed prior to use. Never hold a Live Line Tester between the handguard and the contact electrode. Always prove the Live Line Tester before AND after use. 1 Holding the Live Line Tester by the handles, above the handguards, connect the instrument to a Seaward PH3-LLT proving unit and verify that the LED indicators are illuminated. 2 Holding the Live Line Tester by the handle, above the handguards, place the contact electrodes in contact with the circuit under test. 3 If the LED indicators are illuminated there is a voltage greater than the threshold voltage present at the probe tips. 4 If the LED indicators do not illuminate any voltage present at the probe tips is less than the threshold voltage. 5 Repeat step 1 above to verify that the instrument is still operational.

Other Test Equipment Manuals