Satelliten- und Kabelfernsehanlagen/Industrievertretung GmbH SAT Kabel - ® IRM 5 Pulse reflectometer ...
This instruction has been performed to the best of our knowledge. Developments and technical amendments are subject to change without notice. Topical made operating instructions in a PDF format can also downloaded from our Internet homepage www.sat-kabel.de. ©2012 SAT-Kabel GmbH We thank you for buying of a product of the company SAT-Kabel This operating instructions shall help you to understand the functions of the instrument and ...
Content 1. General 4 2. Delivery volume 4 3. 4. Charging 4 5. Important Notes 5 6. Operational elements 5 7. Operating 5 7.1 Operating functions standard 5 7.2 Advanced operating functions 6 7.2.1 Pulse Amplifier 6 7.2.2 Parameter of length measurement adjust 6 7.2.3 Vertical resolution 7 7.2.4 Start mode setting 7 7.3 Change of the cable characteristic values 8 8. Measuring with the pulse reflectometer 8 8.1 Basic principle 8 8.2 P ...
1. General 2. Delivery volume 4. Charging 3. Measurement principle The is a impulse reflectometer, processor controlled, with LCD display for check and locate faults in telecommunication and power cables. For a more accurate analysis the return loss of coaxial cables is measured additionally. It is handy and easy to operate. The special features are: already 20 cable types are pre-programmed, additional types can be added in the men ...
3 Operating keys LCD-Display Charging socket Measuring socket 1 2 3 down up mode 1 2 3 down up mode = push long the single key >1 s (here key 3) = simultaneously push long two keys >1 s (here keys 1 and 2) = simultaneously push long two keys >1 s (here keys 1 and 3 – reserved for storage) = push shortly the single key (here key 3) = push shortly one of the two keys (here key 2 or 1 – one step forward /back) 5. Important notes 6. ...
7.2 Advanced operating functions 7.2.1 Pulse amplifier 7.2.2 Parameter of length measurement adjust Resolution | Firstly can be adjusted in the menu the resolution of the trace in steps. By long pressing of the button 3 - until the icons appear inverted - you get to the first parameter of the measurement. Here can be set with the buttons 1 or 2 the required value. During switching on the state of charge of the battery in the display ...
propagation factor Filter pulse width Resolution measuring trace (without reflection) transmit pulse (0,0 m) Cursor 7.2.3 Vertical resolution By long pushing of the keys 1 and 2 the zoom can be switched on or off. Referred to the operating scheme on page 6 and 7, the zoom only can used to functions under the dashed line. If the zoom is switched on, the entire display is used for the display of the measuring curve. An already set gai ...
0.80 / 3.50 CPE ON P: 1 v/c=0.83 5.7 dB 8. Measuring with the pulse reflectometer 8.1 Basic principle The basic physical principle is the echo. There are here signals sent out in e.g. the form of sound. If they hit an obstacle, then a part of it is sent back again, therefore reflected. Simple examples are the echo of a rock wall or the sonar in the maritime. This principle works the same as well on electric lines. Only one takes as ...
back at the sending point. To get accurate results, you need to pay attention to something: e. g., that the cable offers a resistance to the signals. This in turn depends on the structure of the cable. There is except of the cable loss still a very important parameter - the propagation factor. Very important for coaxial cable is the characteristic impedance and consequently the adaptation or matching. On this basis the measurements ...
Measuring cursor determined length propagation factor at 8.3 Length and distance measurement - for the practitioner The main application of a pulse reflectometer is determining the cable length, either the length of a laid cable or the distance routed to a certain modification, such as cable failure, inserted component. There are only two ideal states: 1. The cable matches - only transmit pulse recognizable Resistance equal to 75 o ...
length measuring range 0-100m (minimum resolution of 1 m here) length measuring range 0-25 m (minimum resolution of 0.2 m here) changed pulse width narrow pulse normal pulse width fault location (open cable here) could also be a fault – here, however, a well-known cable connection by using a so-called »forward wire« cable type from storage location 15 may be a further defect, but first is the error on the cursor to eliminate In ...
An important statement about the quality of a cable or components present in the line allowed the return loss, also reflection attenuation (dBRL) called. Since most taps and splitter have a lower return loss as coaxial cable, it is of interest if these are still intact. In intact coaxial cables the return loss is in the range of about 45 ... 65 dB. Everything else indicates more or less an existing fault. For the passive components ...
return loss return loss against 0 dBRL error - this cable end open storage location of the cable type storage location of the cable type 9. Technical data Measuring ranges Resolution switchable Accuracy of the measuring range Propagation factor Storage places for cable type and propagation factor already 20 pre-programmed Sensitivity Digital filter switchable for suppression of external voltages on the cable Output F-socket Output ...
10. Operating scheme IRM 5 Measuring of the return loss after Switch off: Store values: Cable selection (storage place) Measuring curve Cursor Resolution 0,2/…/4 m Resolution 0,2/…/4 m Gain V: 0/4/8/…/36 Pulse width 5/20/100 ns Filter (on/off) In all measurement menus – 44 dB dynamics – high vertical resolution vertical resolution high / normal ...
©SAT-Kabel ® Measuring without return loss after Switch off: Store values: Cursor Resolution 0,2/…/4 m Gain V: 0/4/8/…36 Pulse width 5/20/100 ns Filter (ein/aus) Storage place for propagations factor Propagations factor 0,25…0,999 = Push key long (>1 s) = Do not push the key! = Push shortly the key = Alternative push key shortly Legend: ...
program cable type cable diameter kind of propagation cable attenuation at ielectric place designation inner conductor dielectric d factor 50 MHz at 100 m P 1 mini cable 0.41 mm 1.90 mm CPE 0.78 10.9 dB P 2 H 123 0.65 mm 2.90 mm CPE 0.85 7.5 dB P 3 COAX 12 0.70 mm 4.60 mm PF 0.66 5.6 dB P 4 H 121., MK 75 0,80 mm 3,50 mm CPF 0,84 5.7 dB P 5 H 126 DUOBOND PLUS, KOKA 799 1.00 mm 4.60 mm CPE 0.82 4.5 dB P 6 MK 15, LCD 90 1.02 mm 4.40 m ...
The surface of the housing can be cleaned with a dry, soft and lintfree cloth. Do not use aggressive solvents for the cleaning. 12. Cleaning 13. Guarantee State July 2006 For this instrument will be granted a service life (in following called guarantee) to following conditions: This guarantee is valid for new instruments purchased in Germany. New instruments and their components, which are defective because of production faults and ...