R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA

TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com P/N: 05305L-90 REV: J111215 WIND MONITOR-AQ WITH 4-20mA OUTPUTS MODEL 05305L ...

with 4-20mA OUTPUTS

INTRODUCTION The Wind Monitor measures horizontal wind speed and direction. Developed for air quality applications, it is accurate, sensitive, and corrosion resistant. The main housing, nose cone, propeller, and other internal parts are injection molded U.V. stabilized plastic. The tail section is lightweight expanded polystyrene. Both the propeller and vertical shafts use stainless steel ...

Initial installation is most easily performed using two people; one

to adjust instrument position and the other to observe an indicating device. After initial installation with the included orientation ring, the instrument can be removed and returned to its mounting without re-alignment. Install the Wind Monitor following these steps: 1. MOUNT WIND MONITOR a) Place orientation ring on mounting post. Do Not tighten band clamp yet. (Ori ...

*Max set screw torque 80 oz-in

4. INSTALL NEW POTENTIOMETER a) Push new potentiometer into potentiometer mounting & coil assembly making sure o-ring is on shaft. b) Feed potentiometer and coil wires through hole in bottom of potentiometer housing. c) Screw potentiometer housing onto potentiometer mounting & coil assembly. d) Gently pull transducer wires through bottom of potentiometer housing to take up any slack. Apply a small amount ...

This device complies with Part 15 of the FCC Rules. Operation

is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits a ...

WIND SPEED vs mA OUTPUT

m/s = ( 6.250 x mA)-25 knots = (12.125 x mA)-48.6 mph = (13.980 x mA)-56 km/h = (22.500 x mA)-90 WIND DIRECTION vs mA OUTPUT DEGREES = (22.5 x mA)-90 CABLE & WIRING DIAGRAM MODEL 05305L WIND MONITOR ...

05194 PROPELLER NUT WRENCH

08254 PROPELLER - 20CM X 30CM (CARBON FIBER THERMOPLASTIC) 05363 FLANGE BEARING (2) 05360A NOSE CONE ASSY 05158 NOSE CONE O-RING 05161A 6-POLE MAGNET & SHAFT COLLAR 05374 MAIN HOUSING AND TAIL ASSY - AQ 05138A POTENTIOMETER COUPLING 05139 POT ADJUST THUMBWHEEL 05145C POTENTIOMETER MOUNTING & COIL ASSEMBLY 05334 POTENTIOMETER 10K 1/4% LIN, CONDUCTIVE PLASTIC 05131D POTENTIOMETER HOUSING 05330D TRANSDUCER ASSEMB ...

Vane Angle Bench Stand

Model 18310 Propeller Torque Disc Model 18331 Vane Torque Gauge Model 18301 Vane Alignment Rod Model 18212 Vane Angle Fixture-Tower Mount ...

Model 18802 Anemometer Drive provides a convenient and accurate way to rotate an anemometer shaft at

a known rate. The motor may be set to rotate clockwise or counter-clockwise at any rate between 200 and 15,000 RPM in 100 RPM increments. The LCD display is referenced to an accurate and stable quartz timebase. For completely portable operation, the unit can be operated on internal batteries. For extended operation, an AC wall adapter is included. Model 188 ...